The text
A rig shall have emergency lighting that,
(a) turns on automatically when the regular lighting fails;
(b) is independent of the regular lighting source;
(c) provides adequate lighting for evacuation of the area; and
(d) is tested at least once every three months, but not less frequently than recommended by the manufacturer to ensure the system will function in an emergency,
in every workplace that is,
(e) a communication centre;
(f) a drill floor;
(g) a well control area;
(h) a stairway;
(i) an exit;
(j) a machinery generator area;
(k) an area where lighting is required for well control;
(l) a passageway;
(m) a navigation control area; or
(n) a survival craft embarkation station. R.R.O. 1990, Reg. 855, s. 56.