OIL AND GAS — OFFSHORE, R.R.O. 1990, Reg. 855

Section 52

Cite as OIL AND GAS — OFFSHORE, R.R.O. 1990, Reg. 855, s. 52 · current to November 11, 2026 · consolidated from July 1, 2022 · read from e-Laws on November 16, 2026

The text

(1) There shall be a guardrail, (a) at the perimeter of any area where there is a drop of more than one metre; (b) on a mud tank; and (c) where there is a hazard of falling into water or other hazardous material. R.R.O. 1990, Reg. 855, s. 52 (1). (2) A guardrail shall consist of, (a) a top rail not less than 107 centimetres above the surface, floor or platform; (b) a mid rail located approximately mid way between the top rail and walking surface; and (c) posts or uprights, supporting the top rail and spaced not more than three metres apart from centre to centre. R.R.O. 1990, Reg. 855, s. 52 (2). (3) A guardrail shall, (a) be capable of withstanding any load likely to be applied to it; and (b) where tools or other objects may fall on any worker, have a toe-board extending from the surface, floor or platform to a height of not less than 125 millimetres. R.R.O. 1990, Reg. 855, s. 52 (3); O. Reg. 421/10, s. 10.
Read the OIL AND GAS — OFFSHORE on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.