MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854
Section 77
Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 77 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026
The text
(1) Subject to subsection (2), the manway in a shaft shall be separated from the hoisting or counterweight compartments by a partition which complies with subsection 76 (2). R.R.O. 1990, Reg. 854, s. 77 (1).
(2) Between levels, the partition may consist of metal of suitable weight and mesh to prevent,
(a) a falling object from entering the manway; or
(b) the intrusion of an object from the manway into the hoisting compartment. R.R.O. 1990, Reg. 854, s. 77 (2).
(3) A safe passageway and standing room for a person outside the shaft shall be provided at all workings opening into a shaft and the manway shall be directly connected with such openings. R.R.O. 1990, Reg. 854, s. 77 (3).
Read the MINES AND MINING PLANTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.