MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 47

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 47 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) A ladder shall, (a) be of strong construction; (b) be free from broken or loose members or other faults; (c) be installed and maintained so as to reduce to a minimum the hazard of a person falling therefrom; (d) if made of wood, (i) be of sound straight-grain lumber, (ii) not be painted or otherwise treated in a manner to obscure the grain; (e) have a distance between centres of the rungs not greater than 300 millimetres or less than 250 millimetres; (f) have the spacing between rungs not vary more than fifteen millimetres in a ladderway; (g) have not less than 100 millimetres clearance behind any rung from a wall or any timber or obstruction underneath the ladder; and (h) project at least one metre above the landing or opening unless strong handholds are provided above the top of the ladder. R.R.O. 1990, Reg. 854, s. 47 (1). (2) A fixed ladder shall be securely fastened in place. R.R.O. 1990, Reg. 854, s. 47 (2).
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.