MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 164

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 164 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) Electrical mobile equipment operating at more than 300 volts to ground shall be supplied by a system wherein, (a) the neutral is grounded through a current limiting device in such a manner as to limit the possible rise of ground fault potential to a maximum of 100 volts to ground; and (b) ground fault protection is provided. R.R.O. 1990, Reg. 854, s. 164 (1). (2) Electrical mobile equipment operating at more than 300 volts to ground must have a fail safe circuit that prevents the supply of electricity to the equipment when the conductivity of the ground return circuit is not continuous. O. Reg. 272/97, s. 29 (1). (3) In this section, “electrical mobile equipment” means equipment which, during its operating cycle, is required to move along the ground while energized and which receives its current through a trailing cable and includes drills which connect to an electrical power supply. O. Reg. 272/97, s. 29 (2). 165., 166. Revoked: O. Reg. 486/99, s. 7.
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.