MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854

Section 152

Cite as MINES AND MINING PLANTS, R.R.O. 1990, Reg. 854, s. 152 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

(1) When a common electrical source is used to fire blasts in more than one workplace provision shall be made for, (a) the continued shorting of the blasting cables; (b) a three-way switch for each individual blasting circuit which can be locked in either the shorted or closed position to provide for, (i) shorting of the circuit, (ii) energizing the circuit, and (iii) testing of the circuit; (c) identification of blasting cables and switches; and (d) a written blasting procedure setting forth, (i) the method of connecting the blasting wires to the electrical supply, (ii) the evacuation of all workers from the area of the blast, and (iii) the method of testing the system to ensure that the proper connections have been made. R.R.O. 1990, Reg. 854, s. 152 (1). (2) The written blasting procedure shall be followed. R.R.O. 1990, Reg. 854, s. 152 (2).
Read the MINES AND MINING PLANTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.