The text

(1) Subject to subsection (2), the bottom of a cupola shall be supported by one or more adequate metal props with metal bases and wedges supported on concrete or other solid footing. R.R.O. 1990, Reg. 851, s. 96 (1). (2) The bottom of a cupola shall be dropped only, (a) after a visual and audible warning signal has been given for at least three minutes; and (b) by having the prop or props removed by a winch or similar device operated from outside a wall or shield at the cupola or from another safe location. R.R.O. 1990, Reg. 851, s. 96 (2). (3) As soon as is practicable after a cupola is emptied, coke slag and unmelted metal from the dropping of the cupola bottom shall be removed by a mechanical rake or other mechanical means. R.R.O. 1990, Reg. 851, s. 96 (3).
Read the INDUSTRIAL ESTABLISHMENTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.