(1) Subject to subsections (2) and (3), where molten metal is conveyed, the minimum width of a gangway for one-way traffic shall be as specified in the following Table: TABLE Type of Metal Container | Number of Workers Conveying Metal | Minimum Width Hand shank ladles and crucibles | 2 or less | 90 centimetres Hand shank ladles and crucibles | More than 2 | 120 centimetres Ladle or crucible on truck, buggy or overhead track | Not applicable | 60 centimetres wider than greatest width of ladle, crucible, truck, buggy or container support (2) Where a gangway is used for traffic in both directions but molten metal is conveyed in one direction only, the width required by subsection (1) shall be increased by at least ninety centimetres. R.R.O. 1990, Reg. 851, s. 90 (2). (3) Where a gangway is used for carrying molten metal in both directions, the width required by subsection (1) shall be doubled. R.R.O. 1990, Reg. 851, s. 90 (3). (4) Where a ladle is carried by an overhead crane, (a) adequate warning shall be given before the ladle is moved; and (b) the danger area over which it is transported shall be clear of any worker. R.R.O. 1990, Reg. 851, s. 90 (4).
Read the INDUSTRIAL ESTABLISHMENTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.