INDUSTRIAL ESTABLISHMENTS, R.R.O. 1990, Reg. 851

Section 88

Cite as INDUSTRIAL ESTABLISHMENTS, R.R.O. 1990, Reg. 851, s. 88 · current to November 11, 2026 · consolidated from July 1, 2022 · read from e-Laws on November 16, 2026

The text

(1) A clear space adequate for safe operating and maintenance purposes shall be provided between the outer shell of any cupola or other melting unit and any wall, structure, equipment or operation. R.R.O. 1990, Reg. 851, s. 88 (1). (2) Subject to subsection (5), the width of any passageway or aisle adjacent to a melting unit shall not be less than 1.2 metres. R.R.O. 1990, Reg. 851, s. 88 (2). (3) The firing portion and fuel supply controls of each melting unit shall be accessible from an aisle or be in a location remote from a melting unit. R.R.O. 1990, Reg. 851, s. 88 (3). (4) Subject to subsection (5), the dimensions of the working space at any melting unit shall not be less than 1.8 metres measured horizontally from the furnace shell or pouring spout or such additional clearance as is required for safe working. R.R.O. 1990, Reg. 851, s. 88 (4). (5) Subsections (2) and (4) do not apply to a melting unit installed before the 31st day of July, 1964. R.R.O. 1990, Reg. 851, s. 88 (5).
Read the INDUSTRIAL ESTABLISHMENTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.