INDUSTRIAL ESTABLISHMENTS, R.R.O. 1990, Reg. 851
Section 13
Cite as INDUSTRIAL ESTABLISHMENTS, R.R.O. 1990, Reg. 851, s. 13 · current to November 11, 2026 · consolidated from July 1, 2022 · read from e-Laws on November 16, 2026
The text
(1) Subject to subsection (2), there shall be a guardrail,
(a) around the perimeter of an uncovered opening in a floor, roof or other surface to which a worker has access;
(b) at an open side of,
(i) a raised floor, mezzanine, balcony, gallery, landing, platform, walkway, stile, ramp or other surface, or
(ii) a vat, bin or tank, the top of which is less than 107 centimetres above the surrounding floor, ground, platform or other surface; and
(c) around a machine, electrical installation, place or thing that is likely to endanger the safety of any worker. R.R.O. 1990, Reg. 851, s. 13 (1).
(2) Subsection (1) does not apply to,
(a) a loading dock;
(b) a roof to which access is required only for maintenance purposes;
(c) a pit used for,
(i) work on an assembly line, or
(ii) maintenance of vehicles or similar equipment; and
(d) a conveyor or similar system that transports a vehicle or vehicle part, and any raised platform used with the conveyor or similar system, if a guardrail would,
(i) obstruct the passage of the vehicle or vehicle part,
(ii) prevent a worker from performing work, or
(iii) pose a hazard to a worker. R.R.O. 1990, Reg. 851, s. 13 (2); O. Reg. 456/18, s. 1 (1).
(3) If there is no guardrail in a situation described in subsection (2), an employer shall develop and implement other measures and procedures to protect workers from the hazard of falling. O. Reg. 456/18, s. 1 (2).
Read the INDUSTRIAL ESTABLISHMENTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.