X-RAY SAFETY CODE, R.R.O. 1990, Reg. 543
Section 23
Cite as X-RAY SAFETY CODE, R.R.O. 1990, Reg. 543, s. 23 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026
The text
Every cephalometric x-ray machine shall be equipped with a beam limiting device that limits the size of the useful beam to maximum linear dimensions of thirty-one centimetres by thirty-eight centimetres at the plane of the image receptor. R.R.O. 1990, Reg. 543, s. 23.
TABLE 1
Item | Column 1 Class of Student | Column 2 Supervisor
1. | Medical student | Radiologist
2. | Dental student | Dentist or out of province Dentist
3. | Dental Hygiene student | Dentist or out of province Dentist
4. | Dental Assisting student | Dentist or out of province Dentist
5. | Chiropractic student | Chiropractor
6. | Medical Radiation and Imaging Technologist student | Radiologist or Medical Radiation and Imaging Technologist or out of province Medical Radiation and Imaging Technologist
TABLE 2
Item | Column 1 Class of Radiation Protection Officer | Column 2 Class of Facility
1. | Medical radiation protection officer | Medical facility
2. | Dental radiation protection officer | Dental facility
3. | Chiropractic radiation protection officer | Chiropractic facility
4. | Chiropodic radiation protection officer | Chiropody facility
TABLE 3 Dental Facility
Item | Column 1 Test or Procedure | Column 2 Frequency
1. | Photographic quality control | Every operational day
2. | Patient entrance exposure measurements | Every twelve months and upon alteration or servicing of the machine
3. | Collimation | Every twelve months and upon alteration of servicing of the machine
4. | Half-value layer | Every twelve months and upon alteration or servicing of the machine
TABLE 4 Chiropodic Facility
Item | Column 1 Test or Procedure | Column 2 Frequency
1. | Photographic quality control | Every operational day
2. | Patient entrance exposure measurements | Every twenty-four months and upon alteration or servicing of the machine
3. | Collimation | Every twelve months and upon alteration or servicing of the machine
4. | Half-value layer | Every twelve months and upon alteration or servicing of the machine
TABLE 5 Medical and Chiropractic Facilities
Item | Column 1 Test or Procedure | Column 2 Frequency
1. | Photographic quality control | Every operational day
2. | Patient entrance exposure measurements and, for every mammographic x-ray machine, calculation of mean glandular breast dose | Every six months and upon alteration or servicing of the machine
3. | Collimation | Every six months and upon alteration or servicing of the machine
4. | Half-value layer | Every six months and upon alteration or servicing of the machine
5. | Phototiming parameters including operation of back-up timer | Every six months
6. | Fluoroscopic parameters, including, (a) maximum patient entrance exposure rate (b) resolution (c) limit timer (d) automatic brightness control | Every six months and upon servicing of the machine
7. | Tomographic parameters, including fulcrum accuracy, thickness of cut and mechanical stability | Every six months
TABLE 6
Item | Column 1 Projection | Column 2 Patient Thickness (standard for test purposes) | Column 3 Source-to-image distance | Column 4 Maximum entrance exposure (exposures expressed as exposure in air without backscatter) expressed in milliroentgens
1. | Abdomen AP | 23 cm | 100 cm | 450
2. | Cervical Spine AP | 13 cm | 100 cm | 120
3. | Chest PA | 23 cm | 180 cm | 20
4. | Foot (Dorso-Plantar) Direct Film | 8 cm | 100 cm | 200
5. | Full Spine | 23 cm | 180 cm | 250
6. | Intravenous Pyelogram | 23 cm | 100 cm | 500
7. | Lumbar Spine AP | 23 cm | 100 cm | 500
8. | Lumbar Spine Lateral | 32 cm | 100 cm | 2,000
9. | Revoked: O. Reg. 663/00, s. 4.
10. | Skull Lateral | 15 cm | 100 cm | 170
11. | Thoracic Spine AP | 23 cm | 100 cm | 400
TABLE 7
Item | Column 1 Projection | Column 2 Peak Kilovoltage | Column 3 Maximum entrance exposure expressed in milliroentgens
1. | Posterior Bitewings | 50 | 550
2. | Posterior Bitewings | 60 | 475
3. | Posterior Bitewings | 70 | 360
4. | Posterior Bitewings | 80 | 280
5. | Posterior Bitewings | 90 | 220
TABLE 8
Item | Column 1 Measured Potential (kilovolts peak) | Column 2 Minimum Half-value Layer (millimetres of aluminum)
1. | 30 | 0.3
2. | 40 | 0.4
3. | 49 | 0.5
4. | 50 | 1.2
5. | 60 | 1.3
6. | 70 | 1.5
7. | 71 | 2.1
8. | 80 | 2.3
9. | 90 | 2.5
10. | 100 | 2.7
11. | 110 | 3.0
12. | 120 | 3.2
13. | 130 | 3.5
14. | 140 | 3.8
15. | 150 | 4.1
Read the X-RAY SAFETY CODE on e-Laws ↗
Made under Healing Arts Radiation Protection Act, R.S.O. 1990, c. H.2.