X-RAY SAFETY CODE, R.R.O. 1990, Reg. 543

Section 23

Cite as X-RAY SAFETY CODE, R.R.O. 1990, Reg. 543, s. 23 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026

The text

Every cephalometric x-ray machine shall be equipped with a beam limiting device that limits the size of the useful beam to maximum linear dimensions of thirty-one centimetres by thirty-eight centimetres at the plane of the image receptor. R.R.O. 1990, Reg. 543, s. 23. TABLE 1 Item | Column 1 Class of Student | Column 2 Supervisor 1. | Medical student | Radiologist 2. | Dental student | Dentist or out of province Dentist 3. | Dental Hygiene student | Dentist or out of province Dentist 4. | Dental Assisting student | Dentist or out of province Dentist 5. | Chiropractic student | Chiropractor 6. | Medical Radiation and Imaging Technologist student | Radiologist or Medical Radiation and Imaging Technologist or out of province Medical Radiation and Imaging Technologist TABLE 2 Item | Column 1 Class of Radiation Protection Officer | Column 2 Class of Facility 1. | Medical radiation protection officer | Medical facility 2. | Dental radiation protection officer | Dental facility 3. | Chiropractic radiation protection officer | Chiropractic facility 4. | Chiropodic radiation protection officer | Chiropody facility TABLE 3 Dental Facility Item | Column 1 Test or Procedure | Column 2 Frequency 1. | Photographic quality control | Every operational day 2. | Patient entrance exposure measurements | Every twelve months and upon alteration or servicing of the machine 3. | Collimation | Every twelve months and upon alteration of servicing of the machine 4. | Half-value layer | Every twelve months and upon alteration or servicing of the machine TABLE 4 Chiropodic Facility Item | Column 1 Test or Procedure | Column 2 Frequency 1. | Photographic quality control | Every operational day 2. | Patient entrance exposure measurements | Every twenty-four months and upon alteration or servicing of the machine 3. | Collimation | Every twelve months and upon alteration or servicing of the machine 4. | Half-value layer | Every twelve months and upon alteration or servicing of the machine TABLE 5 Medical and Chiropractic Facilities Item | Column 1 Test or Procedure | Column 2 Frequency 1. | Photographic quality control | Every operational day 2. | Patient entrance exposure measurements and, for every mammographic x-ray machine, calculation of mean glandular breast dose | Every six months and upon alteration or servicing of the machine 3. | Collimation | Every six months and upon alteration or servicing of the machine 4. | Half-value layer | Every six months and upon alteration or servicing of the machine 5. | Phototiming parameters including operation of back-up timer | Every six months 6. | Fluoroscopic parameters, including, (a) maximum patient entrance exposure rate (b) resolution (c) limit timer (d) automatic brightness control | Every six months and upon servicing of the machine 7. | Tomographic parameters, including fulcrum accuracy, thickness of cut and mechanical stability | Every six months TABLE 6 Item | Column 1 Projection | Column 2 Patient Thickness (standard for test purposes) | Column 3 Source-to-image distance | Column 4 Maximum entrance exposure (exposures expressed as exposure in air without backscatter) expressed in milliroentgens 1. | Abdomen AP | 23 cm | 100 cm | 450 2. | Cervical Spine AP | 13 cm | 100 cm | 120 3. | Chest PA | 23 cm | 180 cm | 20 4. | Foot (Dorso-Plantar) Direct Film | 8 cm | 100 cm | 200 5. | Full Spine | 23 cm | 180 cm | 250 6. | Intravenous Pyelogram | 23 cm | 100 cm | 500 7. | Lumbar Spine AP | 23 cm | 100 cm | 500 8. | Lumbar Spine Lateral | 32 cm | 100 cm | 2,000 9. | Revoked: O. Reg. 663/00, s. 4. 10. | Skull Lateral | 15 cm | 100 cm | 170 11. | Thoracic Spine AP | 23 cm | 100 cm | 400 TABLE 7 Item | Column 1 Projection | Column 2 Peak Kilovoltage | Column 3 Maximum entrance exposure expressed in milliroentgens 1. | Posterior Bitewings | 50 | 550 2. | Posterior Bitewings | 60 | 475 3. | Posterior Bitewings | 70 | 360 4. | Posterior Bitewings | 80 | 280 5. | Posterior Bitewings | 90 | 220 TABLE 8 Item | Column 1 Measured Potential (kilovolts peak) | Column 2 Minimum Half-value Layer (millimetres of aluminum) 1. | 30 | 0.3 2. | 40 | 0.4 3. | 49 | 0.5 4. | 50 | 1.2 5. | 60 | 1.3 6. | 70 | 1.5 7. | 71 | 2.1 8. | 80 | 2.3 9. | 90 | 2.5 10. | 100 | 2.7 11. | 110 | 3.0 12. | 120 | 3.2 13. | 130 | 3.5 14. | 140 | 3.8 15. | 150 | 4.1
Read the X-RAY SAFETY CODE on e-Laws ↗

Made under Healing Arts Radiation Protection Act, R.S.O. 1990, c. H.2.