ZONING ORDER — CITY OF TORONTO, O. Reg. 229/25

Section 6

Zoning requirements

Cite as ZONING ORDER — CITY OF TORONTO, O. Reg. 229/25, s. 6 · current to November 11, 2026 · consolidated from October 3, 2025 · read from e-Laws on November 16, 2026

The text

The zoning requirements for the uses permitted under section 5 are the following: 1. The total maximum gross floor area is 30,000 square metres. 2. Any part of a building or structure at or above grade is subject to the following setback requirements: i. A minimum of 5 metres from the south lot line. ii. A minimum of 12 metres from the west lot line. iii A minimum of 14 metres from the north lot line. iv. A minimum of 45 metres from the east lot line abutting East Avenue. v. A minimum of 24 metres from the east lot line abutting 98 Island Road. 3. The following structures may encroach within the required minimum building setbacks set out in paragraph 2 by a maximum of 0.5 metres: i. Eaves. ii. Cornices. iii. Roof overhangs. iv. Lighting fixtures. v. Pilasters. vi. Chimney breasts. vii. Bay windows. viii. Window sills. ix. Other architectural features. 4. The following structures may encroach within the required minimum building setbacks set out in paragraph 2 by a maximum of 3.5 metres: i. Awnings. ii. Canopies. 5. The following structure may encroach within the required minimum building setbacks set out in paragraph 2 by a maximum of 2.0 metres: i. Balconies. 6. The following structures may encroach within the required minimum building setbacks set out in paragraph 2 with no maximum encroachment, provided they are no higher than 4.5 metres above grade: i. Decks. ii. Terraces. 7. The following structures may encroach within the required minimum building setbacks set out in paragraph 2 with no maximum encroachment, provided they are no higher than 3.5 metres above grade: i. Pergolas. ii. Trellises. iii. Gazebos. iv. Arbours. v. Exterior stairways. vi. Wheelchair ramps. vii. Stairs. viii. Exit stairs. ix. Covered stairs. x. Stair enclosures. xi. Guardrails. xii. Balustrades. xiii. Safety railings. xiv. Bollards. xv. Fences. xvi. Landscape elements. xvii. Retaining walls. 8. The following structures may encroach within the required minimum building setbacks set out in paragraph 2 with no maximum encroachment, provided they are no higher than 7.5 metres above grade: i. Transformers and associated stacks. ii. Generators and associated stacks. 9. The maximum height of any portion of a building or structure shall be, i. 35 metres within 60 metres of the south lot line, and ii. 42 metres beyond 60 metres of the south lot line. 10. The projections associated with the following structures may exceed the maximum height set out in paragraph 9 by up to 2.5 metres: i. Ornamental elements. ii. Parapets. iii. Guardrails. iv. Safety railings. v. Vents. vi. Fences. vii. Wind screens. viii. Privacy screens. ix. Access roof hatches. x. Trellises. xi. Outdoor furniture. xii. Landscape elements, including green roofs. xiii. Roof assemblies. xiv. Terraces. xv. Thermal insulation. xvi. Roof ballasts. xvii. Skylights. 11. The following projections associated with the following structures may exceed the maximum height set out in paragraph 9 by up to 6 metres: i. Mechanical penthouses. ii. Elevator overruns. iii. Stairs. iv. Stair enclosures. v. Cooling towers. vi. Mechanical fans. vii. Flues. viii. Chimneys. ix. Stacks. x. A fence, wall or structure enclosing the projections described in subparagraphs v to ix. 12. Despite paragraph 9, window washing equipment, lightning rods and antennas are not limited to a maximum vertical projection. 13. A minimum of 20 per cent of the area of the lot not covered by buildings or structures must be soft landscaping. 14. A minimum of 128 parking spaces shall be provided. 15. A minimum of 12 bicycle parking spaces shall be provided, indoors or outdoors, composed of the following: i. Four long-term bicycle parking spaces. ii. Eight short-term bicycle parking spaces. 16. A minimum of one Type “G”, one Type “B” and two Type “C” loading spaces shall be provided. 17. Loading spaces may be located in any yard.
Read the ZONING ORDER — CITY OF TORONTO on e-Laws ↗

Made under Planning Act, R.S.O. 1990, c. P.13.