ZONING ORDER — COUNTY OF PRINCE EDWARD, O. Reg. 125/25
Section 6
Specific zoning requirements
Cite as ZONING ORDER — COUNTY OF PRINCE EDWARD, O. Reg. 125/25, s. 6 · current to November 11, 2026 · consolidated from January 19, 2026 · read from e-Laws on November 16, 2026
The text
(1) The following zoning requirements apply to single detached dwellings:
1. The minimum lot area is 250 square metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot area is 200 square metres.
2. The minimum lot frontage is 9 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot frontage is 8 metres.
3. The minimum front yard setback is 2 metres from the nearest part of the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 0.6 metres on one side and 1.2 metres on the other side.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 7 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum rear yard setback is 1.5 metres.
7. The maximum building height is 12 metres.
8. The minimum front yard landscaped open space is 35 per cent.
9. The maximum lot coverage is 70 per cent. O. Reg. 125/25, s. 6 (1); O. Reg. 5/26, s. 3
(2) The following zoning requirements apply to semi-detached dwellings:
1. The minimum lot area is 200 square metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot area is 180 square metres.
2. The minimum lot frontage is 7 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 1.2 metres, but if two semi-detached dwellings on abutting lots share a common wall, no interior side yard is required.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 7 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum rear yard setback is 1.5 metres.
7. The maximum building height is 14 metres.
8. The minimum front yard landscaped open space is 35 per cent.
9. The maximum lot coverage is 75 per cent. O. Reg. 125/25, s. 6 (2).
(3) The following zoning requirements apply to duplex dwellings:
1. The minimum lot area is 250 square metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot area is 200 square metres.
2. The minimum lot frontage is 9 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot frontage is 8 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 0.6 metres on one side and 1.2 metres on the other side.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 7 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum rear yard setback is 1.5 metres.
7. The maximum building height is 14 metres.
8. The minimum front yard landscaped open space is 35 per cent.
9. The maximum lot coverage is 70 per cent. O. Reg. 125/25, s. 6 (3).
(4) The following zoning requirements apply to triplex dwellings:
1. The minimum lot area is 250 square metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot area is 200 square metres.
2. The minimum lot frontage is 9 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot frontage is 8 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 0.6 metres on one side and 1.2 metres on the other side.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 7 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum rear yard setback is 1.5 metres.
7. The maximum building height is 14 metres.
8. The minimum front yard landscaped open space is 35 per cent.
9. The maximum lot coverage is 70 per cent. O. Reg. 125/25, s. 6 (4).
(5) The following zoning requirements apply to townhouse dwellings:
1. The minimum lot area is 160 square metres per unit, except for a through lot or lot which has access from a rear lane, in which case the minimum lot area is 125 square metres per unit.
2. The minimum lot frontage is 6 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 1.2 metres for an end unit.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 7 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum rear yard setback is 1.5 metres.
7. The maximum building height is 14 metres.
8. The minimum front yard landscaped open space is 35 per cent.
9. The maximum lot coverage is 90 per cent.
10. The maximum number of townhouse dwellings in a townhouse building is 8. O. Reg. 125/25, s. 6 (5).
(6) The following zoning requirements apply to back-to-back townhouse dwellings:
1. The minimum lot area is 75 square metres.
2. The minimum lot frontage is 6 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback for an end unit is 1.2 metres, but if two back-to-back townhouse dwellings on abutting lots share a common wall, no interior side yard or rear yard is required.
5. The minimum exterior side yard setback is 2 metres.
6. The maximum building height is 14 metres.
7. The minimum front yard landscaped open space is 35 per cent.
8. The maximum lot coverage is 90 per cent.
9. The minimum depth of a lot for back-to-back townhouse dwellings shall be 13 metres.
10. The maximum number of back-to-back townhouse dwellings in a back-to-back townhouse building shall be 16. O. Reg. 125/25, s. 6 (6).
(7) The following zoning requirements apply to stacked townhouse dwellings:
1. The minimum lot area is 160 square metres.
2. The minimum lot frontage is 6 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 1.2 metres, but if two dwelling units share a common wall, no interior side yard is required.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 1.5 metres.
7. The maximum building height is 14 metres.
8. The minimum front yard landscaped open space is 35 per cent.
9. The maximum lot coverage is 90 per cent.
10. The maximum number of stacked townhouse dwellings in a stacked townhouse building is 32.
11. A stacked townhouse is not required to provide access to a rear yard. O. Reg. 125/25, s. 6 (7).
(8) The following zoning requirements apply to apartment dwellings:
1. The minimum setback from a street line is 2 metres, but the minimum setback is 1 metre where non-residential uses are provided at grade.
2. The minimum interior side yard setback is 1 metre for an apartment dwelling of 23 metres or less in height and 6 metres for an apartment dwelling of more than 23 metres in height, but no interior side yard is required if an existing apartment dwelling and any buildings on abutting lots share a common wall or directly abut the interior lot line.
3. The minimum rear yard setback is 3 metres.
4. The maximum building height in the areas shown as “Picton Base 31 Core 4 (PB31-C4)” and “Picton Base 31 Village 4 (PB31-V4)” on the map referred to in section 2 is 4 storeys or 14 metres.
5. The maximum building height in the areas shown as “Picton Base 31 Core 8 (PB31-C8)” and “Picton Base 31 Village 8 (PB31-V8)” on the map referred to in section 2 is 8 storeys or 30 metres.
6. The maximum building height in the area shown as “Picton Base 31 Core 12 (PB31-C12)” on the map referred to in section 2 is 12 storeys or 42 metres.
7. A minimum of 1 square metre of common indoor amenity space is required per apartment dwelling unit, except in buildings with 12 or fewer dwelling units, in which case no indoor amenity space is required. O. Reg. 125/25, s. 6 (8).
(9) The following zoning requirements apply to boarding or rooming houses:
1. The minimum lot area is 250 square metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot area is 200 square metres.
2. The minimum lot frontage is 9 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum lot frontage is 8 metres.
3. The minimum front yard setback is 2 metres from the dwelling unit and 5.5 metres from the front of a garage.
4. The minimum interior side yard setback is 0.6 metres on one side and 1.2 metres on the other side.
5. The minimum exterior side yard setback is 2 metres.
6. The minimum rear yard setback is 7 metres, except for a dwelling on a through lot or with access from a lane, in which case the minimum rear yard setback is 1.5 metres.
7. The maximum building height is 12 metres.
8. The minimum front yard landscaped open space is 25 per cent.
9. The maximum lot coverage is 70 per cent. O. Reg. 125/25, s. 6 (9).
(10) The following zoning requirements apply to ancillary garden dwellings:
1. The dwelling shall be located within the rear yard of the residential building on the lot and at least 3 metres away from another residential building on the same lot.
2. The minimum interior side yard setback is 0.6 metres.
3. The minimum exterior side yard setback is 2 metres.
4. The minimum rear yard setback is 1.5 metres.
5. The maximum building height is 7.5 metres.
6. The gross floor area is not included for the purpose of calculating the total gross floor area for a lot.
7. The gross floor area must be less than the gross floor area of the principal dwelling unit on the lot.
8. The area of the lot covered by all accessory buildings combined, including an ancillary garden dwelling, may not exceed 20 per cent of the lot area.
9. The area of the lot covered by an ancillary garden dwelling may not exceed,
i. 50 per cent of the area between all rear main walls of the residential building on the lot and the rear lot line, and
ii. a gross floor area of 60 square metres.
10. Vehicle access to a parking space must be provided from a public road or a private lane with an easement. O. Reg. 125/25, s. 6 (10).
(11) The following zoning requirements apply to ancillary laneway dwellings:
1. It must be on a lot with a rear lot line or side lot line abutting a lane for a minimum of 3.5 metres, or on a lot with a cumulative total of a minimum of 3.5 metres along a side lot line and rear lot line.
2. The minimum rear yard setback is,
i. 0 metres if the rear lot line does not abut a street or lane and there are no openings such as vehicle access, doors or windows in the rear main wall of the accessory building, or
ii. 1.5 metres in all other cases.
3. The minimum side yard setback is,
i. 0 metres if the side lot line does not abut a street or lane and there are no openings such as vehicle access, doors or windows in the side main wall of the accessory building,
ii. 2 metres if the side lot line abuts a street, the required minimum side yard setback for the residential building on the lot, or
iii. 0.6 metres in all other cases.
4. It must be at least 3 metres away from a residential building on the same lot.
5. The maximum building length is 10 metres.
6. The maximum building width is 8 metres.
7. The maximum building height is 7 metres.
8. The gross floor area is not included for the purpose of calculating the total gross floor area.
9. The gross floor area must be less than the gross floor area of the residential building on the lot.
10. The structure is not included in the overall calculation of lot coverage.
11. The area of the lot covered by all accessory buildings combined, including an ancillary laneway dwelling, may not exceed 30 per cent of the lot area.
12. Vehicle access to a parking space must be provided from a public road or private lane with an easement. O. Reg. 125/25, s. 6 (11).
(12) The following zoning requirements apply to commercial uses permitted under paragraph 2 of subsection 3 (2) and paragraph 2 of subsection 4 (2):
1. The minimum front yard setback is 1 metre and the maximum front yard setback is 3 metres.
2. The minimum exterior side yard setback is 1 metre.
3. The minimum interior side yard setback is 0 metre when adjacent to a commercial use and 7.5 metres when adjacent to a residential use permitted by this Order.
4. The minimum rear yard setback is 7.5 metres if the commercial use is adjacent to a residential use and 3 metres if it is adjacent to any other use.
5. The minimum building height is 3 metres, except where the commercial use is within an existing building, in which case there is no minimum building height.
6. The maximum building height in the areas shown as “Picton Base 31 Core 4 (PB31-C4)” and “Picton Base 31 Village 4 (PB31-V4)” on the map referred to in section 2 is 4 storeys or 14 metres.
7. The maximum building height in the areas shown as “Picton Base 31 Core 8 (PB31-C8)” and “Picton Base 31 Village 8 (PB31-V8)” on the map referred to in section 2 is 8 storeys or 30 metres.
8. The maximum building height in the area shown as “Picton Base 31 Core 12 (PB31-C12)” on the map referred to in section 2 is 12 storeys or 42 metres.
9. The minimum landscaped area is 25 per cent. O. Reg. 125/25, s. 6 (12).
(13) The following zoning requirements apply to institutional uses permitted under paragraph 3 of subsection 3 (2) and paragraph 3 of subsection 4 (2):
1. The minimum setback to a street line is 3 metres, but the minimum setback is reduced to 1 metre where uses other than a senior citizens’ housing complex or a retirement home are provided at-grade.
2. For a senior citizens’ housing complex or a retirement home, the minimum interior side yard setback is 2 metres for a building of 23 metres or less in height, and 6 metres for a building of more than 23 metres in height, except where any buildings on abutting lots share a common wall or directly abut the interior lot line, in which case, no interior side yard shall be required.
3. The minimum rear yard setback is 6 metres.
4. The maximum building height in the areas shown as “Picton Base 31 Core 4 (PB31-C4)” and “Picton Base 31 Village 4 (PB31-V4)” on the map referred to in section 2 is 4 storeys or 14 metres.
5. The maximum building height in the areas shown as “Picton Base 31 Core 8 (PB31-C8)” and “Picton Base 31 Village 8 (PB31-V8)” on the map referred to in section 2 is 8 storeys or 30 metres.
6. The maximum building height in the area shown as “Picton Base 31 Core 12 (PB31-C12)” on the map referred to in section 2 is 12 storeys or 42 metres.
7. The minimum landscaped area is 25 per cent. O. Reg. 125/25, s. 6 (13).
(14) The following zoning requirements apply to recreational and open space uses permitted under paragraph 4 of subsection 3 (2) and paragraph 4 of subsection 4 (2):
1. The minimum front yard setback is 2 metres to any building or structure.
2. The minimum interior side yard setback from any building or structure is 1.5 metres.
3. The minimum exterior side yard setback from any building or structure is 3 metres.
4. The minimum rear yard setback from any building or structure is 3 metres.
5. The maximum building height for any building or structure is 12 metres. O. Reg. 125/25, s. 6 (14).
(15) For greater certainty, the specific zoning requirements set out in sections 6 to 33 of the zoning by-law do not apply to the uses permitted under subsections 3 (2) and 4 (2). O. Reg. 125/25, s. 6 (15).
Read the ZONING ORDER — COUNTY OF PRINCE EDWARD on e-Laws ↗
Made under Planning Act, R.S.O. 1990, c. P.13.