ZONING ORDER - CITY OF TORONTO, O. Reg. 561/24

Section 6

Zoning requirements

Cite as ZONING ORDER - CITY OF TORONTO, O. Reg. 561/24, s. 6 · current to November 11, 2026 · consolidated from December 20, 2024 · read from e-Laws on November 16, 2026

The text

(1) The lands described in section 2 are deemed to be zoned Commercial Residential (CR) for the purposes of the zoning by-law. (2) Except as otherwise provided for in this Order, the Commercial Residential (CR) Zone requirements set out in sections 40.5 and 40.10 of the zoning by-law apply to the lands described in section 2. (3) The following zoning requirements apply to the uses permitted under section 5: 1. The total maximum gross floor area is 26,000 square metres. 2. The minimum building setbacks for a building or structure are the following: i. 10.0 metres from the south lot line. ii. 3.0 metres from the west lot line. 3. No minimum building setback is required from the north lot line (Rexdale Boulevard) or the east lot line (Vetiver Drive). 4. The following structures may encroach within the required minimum building setbacks set out in paragraph 2: i. Eaves. ii. Awnings. iii. Canopies. iv. Cornices. v. Lighting fixtures. vi. Parapets. vii. Trellises. viii. Balustrades. ix. Mechanical fans, flues, chimneys and stacks. x. Vents. xi. Wheelchair ramps. xii. Retaining walls. xiii. Art and landscape features. xiv. Window sills. xv. Mullions. xvi. Screens, including privacy screens, wind screens and acoustic screens. xvii. Ornamental structures. xviii. Frames. xix. Underground garage ramps. xx. Walkways. xxi. Stairs and stair enclosures. xxii. Stair landings. xxiii. Decks and decking. xxiv. Planters. xxv. Window washing equipment. xxvi. Swimming pools. xxvii. Architectural features. xxviii. Railings. xxix. Dividers. xxx. Fences. xxxi. Mechanical and architectural screens and associated structural elements and equipment. xxxii. Structures associated with green roofs. xxxiii. Access hatchets. xxxiv. Roof assemblies. xxxv. Vents. xxxvi. Pavers. xxxvii. Telecommunications equipment. xxxviii. Structures or elements used for drainage. xxxix. Structures or elements used for green energy and renewable energy facilities. xl. Antennas. xli. Minarets. xlii. Guardrails. 5. The maximum building height is 35 metres. 6. The following structures may exceed the maximum height set out in paragraph 5 by a maximum of 3.5 metres: i. Structures associated with green roofs. ii. Parapets. iii. Access hatches. iv. Roof assemblies. v. Vents. vi. Dividers. vii. Architectural features. viii. Guardrails. ix. Decking. x. Pavers. xi. Telecommunications equipment. xii. Mechanical and architectural screens and associated structural elements and equipment. xiii. Structures or elements used for drainage. xiv. Structures or elements used for green energy and renewable energy facilities. xv. Railings. 7. The following structures may exceed the maximum height set out in paragraph 5 by a maximum of 6 metres: i. Mechanical penthouses and associated structural elements. ii. Cooling towers and associated structural elements. iii. Screens, including privacy screens, wind screens and acoustic screens. iv. Stairs and stair enclosures. 8. The following structures may exceed the maximum height set out in paragraph 5 and are not limited to a maximum vertical projection: i. Window washing equipment. ii. Lightning fixtures. iii. Antennas. iv. Minarets. 9. Minimum and maximum parking space rates as set out in section 200.5.10.1(1) and Table 200.5.10.1 of the zoning by-law, for all other areas of the City of Toronto outside of Parking Zone A (PZA) and Parking Zone B (PZB), apply. 10. A minimum of 0.75 bicycle parking spaces is required for each dwelling unit. 11. The minimum dimensions for a bicycle parking space are the following: i. If placed in a horizontal position, each bicycle parking space must have minimum dimensions of 1.8 metres in length, 0.6 metres in width and 1.22 metres of vertical clearance. ii. If placed in a vertical position, each bicycle parking space must have minimum dimensions of 1.2 metres in length, 0.6 metres in width and 1.9 metres of vertical clearance. 12. Long-term bicycle parking spaces shall be located in a secured room or area. 13. Short-term bicycle parking spaces shall be located in a secured or unsecured room or area. 14. A minimum of one Type “C” loading space, as described in section 40.10.90.1 of the zoning by-law, with minimum dimensions of 6.0 metres in length, 3.5 metres in width and 3.0 metres of vertical clearance is required. (4) In this section, “height” means the vertical distance between grade, being 163.41 metres Canadian Geodetic Datum, and the highest point of a building or structure.
Read the ZONING ORDER - CITY OF TORONTO on e-Laws ↗

Made under Planning Act, R.S.O. 1990, c. P.13.