ZONING ORDER - CITY OF TORONTO, O. Reg. 338/22
Section 7
Zoning requirements, Block 1 Zone
Cite as ZONING ORDER - CITY OF TORONTO, O. Reg. 338/22, s. 7 · current to November 11, 2026 · consolidated from April 8, 2022 · read from e-Laws on November 16, 2026
The text
(1) In addition to the requirements set out in section 6, the requirements in this section also apply to the lands located in the area shown as Block 1 Zone on the map referred to in subsection 2 (1).
(2) A Block 1 tower shall have a maximum tower floor plate area of 800 square metres if such tower contains residential uses.
(3) The maximum height of a building or structure shall be,
(a) 15 metres for the Block 1 base building;
(b) 30 metres for the Block 1 mid-section building; and
(c) 66.8 metres for the Block 1 tower.
(4) The minimum height of the first storey of a building, measured between the floor of the first storey and the ceiling of the first storey, is 4.5 metres.
(5) Subsections (3) and (4) do not apply to a building, structure or portion of a building or structure used for a transportation use.
(6) The minimum building setbacks for a Block 1 base building are as follows:
1. 6.5 metres from the north lot line.
2. 0 metres from the west lot line.
3. 0.7 metres from the south lot line.
4. 0 metres from the east boundary of the Block 1 Zone.
(7) The minimum building setbacks or step backs, as the case may be, for a Block 1 mid-section building are as follows:
1. A setback of 6.5 metres from the north lot line.
2. A setback of 2.5 metres from the west lot line.
3. A setback of 0.7 metres from the south lot line.
4. A step back of 1.0 metres from the south main wall of the Block 1 base building, or the Block 1 mid-section building shall have a minimum horizontal overhang of one metre from the Block 1 base building south main wall.
(8) The minimum building setbacks or step backs, as the case may be, for a Block 1 tower are as follows:
1. A setback of 12.5 metres from the north lot line.
2. A step back of three metres from the south main wall of the Block 1 mid-section building.
3. A step back of three metres from the east and west main walls of the Block 1 mid-section building.
4. A step back of three metres from the north main wall of the Block 1 mid-section building.
(9) Subsections (6) to (8) do not apply to a building, structure or portion of a building or structure used for a transportation use.
Read the ZONING ORDER - CITY OF TORONTO on e-Laws ↗