AIR POLLUTION — DISCHARGE OF SULPHUR DIOXIDE FROM PETROLEUM FACILITIES, O. Reg. 88/22
Section 11
General combustion devices
Cite as AIR POLLUTION — DISCHARGE OF SULPHUR DIOXIDE FROM PETROLEUM FACILITIES, O. Reg. 88/22, s. 11 · current to November 11, 2026 · consolidated from February 25, 2022 · read from e-Laws on November 16, 2026
The text
(1) A person shall not discharge or cause or permit the discharge of sulphur dioxide into the air from a general combustion device at a petroleum facility if the concentration of sulphur dioxide at a measurement point in respect of the device exceeds,
(a) 20 parts per million by volume of sulphur dioxide, averaged over any three-hour period; or
(b) 8 parts per million by volume of sulphur dioxide, averaged over any 365-day period.
(2) Subsection (1) does not apply in respect of a general combustion device unless the approved continuous monitoring plan for the petroleum facility indicates that the concentration of sulphur dioxide discharged into the air from the general combustion device is to be measured.
Read the AIR POLLUTION — DISCHARGE OF SULPHUR DIOXIDE FROM PETROLEUM FACILITIES on e-Laws ↗
Made under Environmental Protection Act, R.S.O. 1990, c. E.19.