ENERGY AND WATER EFFICIENCY — APPLIANCES AND PRODUCTS, O. Reg. 509/18
Schedule 1
Cite as ENERGY AND WATER EFFICIENCY — APPLIANCES AND PRODUCTS, O. Reg. 509/18, Schedule 1 · current to November 11, 2026 · consolidated from January 1, 2025 · read from e-Laws on November 16, 2026
The text
SCHEDULE 1 APPLIANCES AND PRODUCTS GOVERNED BY OTHER EFFICIENCY STANDARDS
PART I EFFICIENCY STANDARDS AND REQUIREMENTS
Integrated clothes washer and dryer, gas-fired
1. The following information applies in respect of an integrated clothes washer and dryer, gas-fired:
1. Definition: A household appliance with a clothes dryer component located above, below or beside a clothes washer component and with both controlled by a common control panel and powered by gas and a single electrical power source.
2. Prescribed efficiency standard or requirement:
i. For clothes drying functions using gas: the prescribed efficiency standard or requirement for a gas-fired residential dryer under this Regulation.
ii. For the clothes washing function: the prescribed energy and water efficiency standard or requirement for a residential clothes washer under this Regulation.
3. Testing standard:
i. For the clothes drying function using gas: the testing standard for a gas-fired residential dryer under this Regulation.
ii. For the clothes washing function: the testing standard for a residential clothes washer under this Regulation.
4. Prescribed date of manufacture: January 1, 2018.
Drinking water cooler, self-contained, with a capacity of up to 21 mL/s
2. The following information applies in respect of a drinking water cooler, self-contained, with a capacity of up to 21 mL/s:
1. Definition: As defined in CSA C815-09, entitled “Energy Performance of Drinking Water Coolers”.
2. Prescribed efficiency standard or requirement: Clause 5.2 and Tables 1 and 2 of CSA C815-09.
3. Testing standard: CSA C815-09.
4. Prescribed date of manufacture: July 1, 2013.
Swimming pool heater, oil-fired
3. The following information applies in respect of a swimming pool heater, oil-fired:
1. Definition: As defined in CSA B140.12-03, entitled “Oil-fired equipment: Service water heaters for domestic hot water, space heating and swimming pools”.
2. Prescribed efficiency standard or requirement: Clause 10.9 of CSA B140.12-03.
3. Testing standard: CSA B140.12-03.
4. Prescribed date of manufacture: July 1, 2013.
Air conditioner, water-cooled or evaporatively-cooled, central, less than 19 kW (65,000 Btu/h)
4. The following information applies in respect of an air conditioner, water-cooled or evaporatively-cooled, central, less than 19 kW (65,000 Btu/h):
1. Definition: A water-cooled or evaporatively-cooled air conditioner that is single-package and ducted, unitary, electrically powered and that is rated below 19 kW (65,000 Btu/h) cooling.
2. Prescribed efficiency standard or requirement: EER ≥ 12.1.
3. Testing standard: U.S. DOE 10 Code of Federal Regulations Part 431, Subpart F, §431.96, entitled “Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps”, as it read on the date the particular appliance or product was manufactured.
4. Prescribed date of manufacture: July 1, 2023.
Air conditioner or heat pump, air-cooled variable refrigerant flow multi-split units, central, less than 19 kW (65,000 Btu/h)
5. The following information applies in respect of an air conditioner or heat pump, air-cooled variable refrigerant flow multi-split units, central, less than 19 kW (65,000 Btu/h):
1. Definition: An air-cooled, variable, refrigerant flow air conditioner or heat pump intended for air conditioning, space heating or both in buildings, that is split-system and centrally ducted, unitary, electrically powered and that is rated below 19 kW (65,000 Btu/h) heating and cooling. For greater clarity, variable refrigerant flow multi-split air conditioners and heat pumps are as defined in U.S. DOE 10 Code of Federal Regulations Part 431, Subpart F, §431.92, entitled “Definitions concerning commercial air conditioners and heat pumps”, but limited to air-cooled units less than 19 kW (65,000 Btu/h).
2. Prescribed efficiency standard or requirement: The minimum EER and HSPF V that is set out in the following Table:
TABLE
Item | Column 1 Product Category | Column 2 Air Conditioner or Heat Pump | Column 3 Minimum EER | Column 4 Minimum HSPF V
1. | Air-cooled VRF multi-split | Air Conditioner | 13.0 | N/A
2. | Air-cooled VRF multi-split | Heat Pump | 13.0 | 6.7
3. Testing standard: U.S. DOE 10 Code of Federal Regulations Part 431, Subpart F, §431.96, entitled “Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps”, as it read on the date the particular appliance or product was manufactured.
4. Prescribed date of manufacture: July 1, 2023.
Heat pump, liquid-to-water, geothermal, excluding direct expansion
6. The following information applies in respect of a heat pump, liquid-to-water, geothermal, excluding direct expansion:
1. Definition: As defined in CAN/CSA C13256-2-01, entitled “Water-source heat pumps — Testing and rating for performance — Part 2: Water-to-water and brine-to-water heat pumps” but limited to geothermal heat pumps.
2. Prescribed efficiency standard or requirement: The EER and COPH that is that set out in the following Table:
TABLE
Item | Column 1 Type of Loop | Column 2 EER | Column 3 COPH
1. | Open-Loop | 13.0 @ 10 °C | 3.1 @ 10 °C
2. | Closed-Loop | 11.5 @ 25 °C | 2.8 @ 0 °C
3. Testing standard: CAN/CSA C13256-2-01.
4. Prescribed date of manufacture: July 1, 2023.
Heat pump, geothermal, direct expansion-to-air
7. The following information applies in respect of a heat pump, geothermal, direct expansion-to-air:
1. Definition: A mechanical-compression type, electrically-driven, factory-made, direct exchange-to-air, geothermal heat pump that has a cooling or heating capacity of less than 35 kW, and that comprises a single-package or matched assemblies. For greater certainty, this includes geothermal systems that are placed in the ground or in the water, or both, and heat pumps where the heat exchanger is field-assembled.
2. Prescribed efficiency standard or requirement: Clause 5.1 of CSA C748-94, entitled “Performance of direct-expansion (DX) ground-source heat pumps”.
3. Testing standard: CSA C748-13.
4. Prescribed date of manufacture: September 1, 1993.
Heat pump, geothermal, liquid-to-air, excluding direct expansion
8. The following information applies in respect of a heat pump, geothermal, liquid-to-air, excluding direct expansion:
1. Definition: As defined in CAN/CSA C13256-1-01, entitled “Water-source heat pumps — Testing and rating for performance — Part 1: Water-to-air and brine-to-air heat pumps”, but limited to geothermal heat pumps.
2. Prescribed efficiency standard or requirement: The COPC and COPH that is set out in the following Table:
TABLE
Item | Column 1 Type of Loop | Column 2 COPC | Column 3 COPH
1. | Open-Loop | 5.27 | 3.7
2. | Closed-Loop | 4.13 | 3.2
3. Testing standard: CAN/CSA C13256-1-01.
4. Prescribed date of manufacture: July 1, 2023.
Heat pump, internal water loop
9. The following information applies in respect of a heat pump, internal water loop:
1. Definition: A water-source single package or split-system heat pump that is factory-built, is intended for installation in an internal water loop system and has a cooling or heating capacity of not more than 40 kW (135,000 Btu/h).
2. Prescribed efficiency standard or requirement:
i. For a cooling capacity < 5 kW, EER ≥ 12.2 and COP ≥ 4.3.
ii. For a cooling capacity ≥ 5 kW and < 19 kW, EER ≥ 13.0 and COP ≥ 4.3.
iii. For a cooling capacity ≥ 19 kW and < 40 kW, EER ≥ 13.0 and COP ≥ 4.3.
3. Testing standard: One of the following:
i. U.S. DOE 10 Code of Federal Regulations Part 431, Subpart F, §431.96, entitled “Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps”, as it read on the date the particular appliance or product was manufactured.
ii. CAN/CSA C13256-1-01, entitled “Water-source heat pumps – Testing and rating for performance – Part 1: Water-to-air and brine-to-air heat pumps”.
4. Prescribed date of manufacture: January 1, 2019.
Heat pump, water-source, variable refrigerant flow
10. The following information applies in respect of a heat pump, water-source, variable refrigerant flow:
1. Definition: A “variable refrigerant flow multi-split heat pump” as defined in U.S. DOE 10 Code of Federal Regulations Part 431, Subpart F, §431.92, entitled “Definitions concerning commercial air conditioners and heat pumps”, as it read on the date the particular appliance or product was manufactured. A “water-source heat pump” means a single-phase or three-phase reverse-cycle heat pump that uses a circulating loop as the heat source for heating and as the heat sink for cooling. The main components are a compressor, a refrigerant-to-water heat exchanger, a refrigerant-to-air heat exchanger, a refrigerant expansion device, a refrigerant reversing valve and an indoor fan.
2. Prescribed efficiency standard or requirement: The EER and COP that is set out in the following Table:
TABLE
Item | Column 1 Cooling Capacity | Column 2 Heating Type | Column 3 Efficiency Level EER | Column 4 Efficiency Level COP
1. | < 5 kW | Without heat recovery | 12.0 | 4.2
2. | < 5 kW | With heat recovery | 11.8 | 4.2
3. | ≥ 5 kW and < 19 kW | All | 12.0 | 4.2
4. | ≥ 19 kW and < 40 kW | All | 12.0 | 4.2
5. | ≥ 40 kW and < 223 kW | Without heat recovery | 10.0 | 3.9
6. | ≥ 40 kW and < 223 kW | With heat recovery | 9.8 | 3.9
3. Testing standard: U.S. DOE 10 Code of Federal Regulations Part 431, Subpart F, §431.96, entitled “Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps”, as it read on the date the particular appliance or product was manufactured.
4. Prescribed date of manufacture: January 1, 2019.
Lamp, fluorescent, self-ballasted compact, and ballasted adapter
11. The following information applies in respect of a lamp, fluorescent, self-ballasted compact, and ballasted adapter:
1. Definition: As defined in CAN/CSA C861-10, entitled “Performance of self-ballasted compact fluorescent lamps and ballasted adapters”.
2. Prescribed efficiency standard or requirement: Clauses 7.6 to 7.11 and Tables 1 to 4 of CAN/CSA C861-10, and in addition, for E26 screwbase lamps only, the requirements for 1,000 hour lumen maintenance, lumen maintenance, rapid cycle stress test and average rated lamp life from U.S. DOE 10 Code of Federal Regulations Part 430, Subpart C, §430.32 (u), entitled “Medium Base Compact Fluorescent Lamps”, as it read on January 1, 2014.
3. Testing standards:
i. For all lamps and ballasted adapters in the category: CAN/CSA-C861-10.
ii. For a E26 screwbase lamp only, for 1,000 hour lumen maintenance, lumen maintenance, rapid cycle stress test and average rated lamp life: U.S. DOE 10 Code of Federal Regulations Part 430, Subpart B, §430.23 (y), entitled “Medium Base Compact Fluorescent Lamps”, as it read on January 1, 2014.
4. Prescribed date of manufacture: January 1, 2016.
Lamp, regulated incandescent
12. The following information applies in respect of a lamp, regulated incandescent:
1. Definition: A “regulated incandescent” lamp as defined in subsection 19 (2) of this Schedule.
2. Prescribed efficiency standard or requirement:
i. Lamp efficacy in lm/W: ≥ 45.
ii. Life: ≥ 1,000 hours.
iii. CRI: ≥ 80.
3. Testing standards:
i. For lamp lumen output and wattage: IES LM-45-15, entitled “IES Approved Method for Electrical and Photometric Measurements of General Service Incandescent Filament Lamps” and published by the IES.
ii. For life: IES LM-49-12, entitled “IES Approved Method for Life Testing of General Lighting Incandescent Filament Lamps” and published by the IES.
iii. For CRI: CIE 13.3-1995, entitled “Method of Measuring and Specifying Colour Rendering Properties of Light Sources”.
iv. For subparagraphs i and ii, the lamp must be tested at 120 volts regardless of its nominal voltage.
4. Prescribed date of manufacture: January 1, 2020.
Lamp, incandescent, candelabra and intermediate screwbase
13. The following information applies in respect of a lamp, incandescent, candelabra and intermediate screwbase:
1. Definition: A “regulated incandescent” lamp as defined in subsection 19 (2) of this Schedule, but without the exemption in paragraph 4 of subsection 19 (4) of this Schedule, and limited to lamps with a screw base of E11, E12 or E17 as specified in ANSI C81.61-2017, entitled “Electrical Lamp Bases - Specifications for Bases (Caps) for Electric Lamps”.
2. Prescribed efficiency standard or requirement:
i. For lamps with an E11 or E12 screw base: maximum rated wattage of 60 W.
ii. For lamps with an E17 screw base: maximum rated wattage of 40 W.
3. Testing standard: not applicable.
4. Prescribed date of manufacture: January 1, 2016.
Luminaire, used for roadway lighting
14. The following information applies in respect of a luminaire, used for roadway lighting:
1. Definition:
i. For HID-based roadway lighting luminaires: the definition set out in CAN/CSA C653-18, entitled “Photometric Performance of Roadway Lighting Luminaires”.
ii. For LED-based roadway lighting luminaires: the definition set out in each of the following documents that corresponds to the applicable testing standard set out in subparagraph 3 ii:
A. ANSI/IES LM-79-19, entitled “Optical and Electrical Measurements of Solid-State Lighting Products”.
B. ANSI/IES LM-80-21, entitled “Measuring Maintenance of Light Output Characteristics of Solid-State Light Sources”.
C. ANSI/IES TM-21-21, entitled “Projecting Long-Term Luminous, Photon, and Radiant Flux Maintenance of LED Light Sources”.
2. Prescribed efficiency standard or requirement:
i. For HID-based roadway lighting luminaires: Clause 4.7 and Tables 4 and 5 of CAN/CSA C653-18.
ii. For LED-based roadway lighting luminaires:
A. Luminaire efficacy: ≥ 100 lm/W.
B. CRI: ≥ 70,
C. Lumen maintenance: L90 ≥ 36,000h, and
D. Lifetime: L70 ≥ 50,000h.
3. Testing standard:
i. For HID-based roadway lighting luminaires: CAN/CSA C653-18.
ii. For LED-based roadway lighting luminaires: ANSI/IES LM-79-19, ANSI/IES LM-80-21 and ANSI/IES TM-21-2.
4. Prescribed date of manufacture: July 1, 2023.
Luminaire, highmast
15. The following information applies in respect of a luminaire, highmast:
1. Definition:
i. For HID-based highmast luminaires: the definition set out in CAN/CSA C811-13, entitled “Performance of Highmast Luminaires for Roadway Lighting”.
ii. For LED-based highmast luminaires: the definition set out in set out in each of the following documents that corresponds to the applicable testing standard set out in subparagraph 3 ii:
A. ANSI/IES LM-79-19, entitled “Optical and Electrical Measurements of Solid-State Lighting Products”.
B. ANSI/IES LM-80-21, entitled “Measuring Maintenance of Light Output Characteristics of Solid-State Light Sources”.
C. ANSI/IES TM-21-21, entitled “Projecting Long-Term Luminous, Photon, and Radiant Flux Maintenance of LED Light Sources”.
2. Prescribed efficiency standard or requirement:
i. For HID-based highmast luminaires: Clause 4.7 and Tables 3, 4, 7 and 8 of CAN/CSA C811-13.
ii. For LED-based highmast luminaires:
A. Luminaire efficacy: ≥ 100 lm/W.
B. CRI: ≥ 70.
C. Lumen maintenance: L90 ≥ 36,000h.
D. Lifetime: L70 ≥ 50,000h.
3. Testing standard:
i. For HID-based highmast luminaires: CAN/CSA C811-13.
ii. For LED-based highmast luminaires: ANSI/IES LM-79-19, ANSI/IES LM-80-21, and ANSI/IES TM-21-21.
4. Prescribed date of manufacture: July 1, 2023.
Transformer, liquid-filled, power, rated from 501 to 10,000 kVA, three-phase
16. The following information applies in respect of a transformer, liquid-filled, power, rated from 501 to 10,000 kVA, three-phase:
1. Definition: As defined in CAN/CSA C802.3-15, entitled “Minimum efficiency values for power transformers”.
2. Prescribed efficiency standard or requirement: Clause 4.2 and Tables 1, 2 and 3 of CAN/CSA C802.3-15.
3. Testing standard: CAN/CSA C802.3-15.
4. Prescribed date of manufacture: July 1, 2018.
Thermostat for room electric space heaters
17. The following information applies in respect of a thermostat for room electric space heaters:
1. Definition: As defined in CSA C828-19, entitled “Performance Requirements for Thermostats Used with Individual Room Electric Space Heating Devices”, but excluding thermostats exclusively used for radiant heating systems.
2. Prescribed efficiency standard or requirement:
i. Maximum absolute thermostat drop in temperature: ≤ 1.5°C.
ii. Maximum difference between the original thermostat set point of 22°C and the average temperature at the centre of the test room for a duty cycle of 50 per cent: ≤ 0.5°C.
iii. Maximum thermostat differential: 0.5°C.
3. Testing standard: CSA C828-19.
4. Prescribed date of manufacture: January 1, 2022.
Window, intended for low-rise residential building
18. The following information applies in respect of a window, intended for low-rise residential building:
1. Definition: A window that separates heated space from unheated space, or from the exterior air, and that is to be installed in a building that is partially or entirely used for residential occupancy, has a building area not exceeding 600 square metres and has a building height of three storeys or less. However, the following windows are excluded:
i. Decorative windows that have stained glass panels, iron inserts or blinds contained in a sealed insulating glass unit.
ii. Heritage replacement windows intended to be installed in a heritage building.
iii. Glazing replacements in an existing sash or frame, if the U-factor of the replacement glazing is equal to or less than the U-factor of the original glazing.
iv. Decorative sidelights for doors.
v. Windows that are designed for a specific building.
vi. Windows that fall outside the scope of the certification programs of the designated organizations described in subsections 9 (2) and (3) of this Regulation.
2. Prescribed efficiency standard or requirement:
i. For basement windows that incorporate a loadbearing structural frame: double-glazed with a low-E coating.
ii. For all other windows: U-factor ≤ 1.61 W/(m²C) or an energy rating ≥ 25.
3. Testing standard: One of the following:
i. CAN/CSA A440.2:19/A440.3:19, entitled “Fenestration energy performance”.
ii. NFRC 100-2020, entitled “Procedure for Determining Fenestration Product U-Factors or for determining the energy rating”.
iii. NFRC 200-2020, entitled “Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence”.
4. Prescribed date of manufacture: January 1, 2022.
PART II INTERPRETATION
Definitions
19. (1) In this Schedule,
“building area”, “building height” and “residential occupancy” have the same meaning as in Ontario Regulation 163/24 (Building Code) made under the Building Code Act, 1992.
(2) In this Schedule,
“ANSI” means the American National Standards Institute;
“ANSI C78.20-2003” means the document entitled “Electric Lamps - A, G, PS And Similar Shapes With E26 Medium Screw Bases” published by ANSI and dated 2003;
“ANSI C81.61-2017” means the document entitled “Electric Lamp Bases - Specifications for Bases (Caps) For Electric Lamps” published by ANSI and dated 2017;
“CAN/CSA” means a CSA standard approved by the Standards Council of Canada as a national standard;
“CIE” means the International Commission on Illumination;
“CIE 13.3-1995” means the method entitled “Method of Measuring and Specifying Colour Rendering Properties of Light Sources” published by the CIE and dated 1995;
“coloured lamp” means a lamp that is marketed as a coloured lamp and that has a colour rendering index of less than 50, as determined in accordance with CIE 13.3-1995, or a correlated colour temperature of less than 2,500 K or greater than 4,600 K;
“COP” means the coefficient of performance and can be in respect of cooling (COPC) and heating (COPH);
“CRI” means the colour rendering index;
“EER” means the energy efficiency ratio;
“heritage replacement window” means a window that conserves, protects or preserves the cultural heritage value of the heritage building;
“household” means manufactured or sold primarily for use in a dwelling;
“HSPF V” means the heating season performance factors — region V;
“IEC” means the International Electrotechnical Commission;
“IEC 60079-0:2011” means the document entitled “Explosive atmospheres” published by the IEC and dated 2011;
“IES” means the Illuminating Engineering Society of North America;
“IES’s Lighting Handbook” means the book entitled “The IESNA Lighting Handbook – Reference and Application”, 9th edition, published by the IES, dated 2000;
“lm/W” means lumens per watt;
“mL/s” means millilitres per second;
“NEMA” means the National Electrical Manufacturers Association;
“NEMA C78.79-14” means the document entitled “Electric Lamps — Nomenclature for Envelope Shapes Intended for Use with Electric Lamps”, published by NEMA and dated 2014;
“NFRC” means the National Fenestration Rating Council;
“regulated incandescent”, in respect of a lamp, means a lamp that,
(a) provides light by heating a filament to incandescence,
(b) is designed to provide a substantially uniform level of illuminance throughout an area,
(c) is not designed for a particular function or purpose,
(d) has a luminous flux of at least 250 lumens but not more than 2,600 lumens,
(e) has a nominal voltage of at least 110 volts but not more than 130 volts, or a nominal voltage range that lies at least partially between those voltages,
(f) is screw-based,
(g) is not a type of lamp listed in subsection (3) or (5) of this section, and
(h) does not have any of the characteristics described in subsection (4) of this section;
“W/(m²C)” means watts per meter squared degrees Celsius.
(3) For the purposes of this Schedule, a regulated incandescent lamp excludes any of the following types of lamps:
1. A reflector lamp: a lamp that described in item 38 of the Table to section 2.
2. A three-way lamp: a lamp that is marketed as a three-way lamp and that employs two filaments, operated separately and in combination, to provide three light levels.
(4) For the purposes of this Schedule, a regulated incandescent lamp excludes a lamp with any of the following characteristics:
1. A lamp that has a G-shape, as specified in ANSI C78.20-2003 and NEMA C78.79-14, with a diameter of 12.7 cm or more.
2. A lamp that has a T-shape, as specified in ANSI C78.20-2003 and NEMA C78.79-14, and a maximum nominal power of 40 W or a length exceeding 25.4 cm.
3. A lamp that has a B, BA, CA, F, G16-½, G25, G30, S or M-14 shape or other similar shape, as specified in ANSI C78.20-2003 and NEMA C78.79-14, and a maximum nominal power of 40 W.
4. A lamp that has a screw base size of E5, E10, E11, E12, E17, E26/50×39, E26/53×39, E29/28, E29/53×39, E39, E39d, EP39 or EX39, as specified in ANSI C81.61-2017.
5. A left-hand thread lamp with a base that screws into a lamp socket in a counter-clockwise direction.
(5) For greater certainty, a regulated incandescent lamp excludes the following types of lamps:
1. A coloured lamp.
2. An appliance lamp: a lamp, including an oven lamp, a refrigerator lamp and a vacuum cleaner lamp, that is specifically designed and marketed to operate in a household appliance and has a maximum wattage of 40 W.
3. An explosion resistant lamp: a lamp that is designed and certified to operate in a Class I, Division 1 or Class II, Division 1 environment, as defined in IEC 60079-02011.
4. A plant lamp: a lamp that contains a filter or coating to suppress light with wavelengths of less than 0.58 µm and that is marketed as a plant lamp.
5. A sign service lamp: a vacuum type or gas-filled lamp that has a sufficiently low bulb temperature to permit exposed outdoor use on high-speed flashing circuits and that is marketed as a sign service lamp.
6. A silver bowl lamp: a lamp that is marketed as a silver bowl lamp and that has a reflective coating applied directly to part of the bulb surface that reflects light toward the lamp base.
7. A traffic signal module: a self-contained device designed to fit into a traffic signal housing and provide drivers with movement information by means of a red or green traffic signal indicator that is either 203.2 mm or 304.8 mm in diameter.
8. A pedestrian module: a self-contained device designed to fit into a pedestrian signal housing and provide pedestrians with movement information by means of a walking person display or a hand display, but not by means of a countdown message.
9. A submersible lamp: a lamp that meets the requirements of CSA C22.2 No. 89-2015, entitled “Swimming-pool Luminaires, Submersible Luminaires and Accessories”.
10. A rough service lamp: a lamp that is marketed as a rough service lamp and that has,
i. a C-7A or C-11 filament, as described in IES’s Lighting Handbook, with at least five supports exclusive of lead wires,
ii. a C-17 filament, as described in IES’s Lighting Handbook, with eight supports exclusive of lead wires, or
iii. a C-22 filament, as described in IES’s Lighting Handbook, with 16 supports exclusive of lead wires.
11. A vibration service lamp: a lamp that,
i. is marketed as a vibration service lamp,
ii. has a maximum nominal power of 60 W, and
iii. has a C-5, C-7A or C-9 filament configuration, as illustrated in figure 6.12 of IES’s Lighting Handbook, or a similar configuration, with less than five supports.
12. A shatter-resistant lamp: a lamp that has an external silicon, polytetrafluoroethylene or similar coating applied for the purpose of resisting breakage and preventing glass from reaching the operating environment in the event of breakage and that is marketed as a shatter-resistant, shatter-proof or shatter-protected lamp.
13. A bug lamp: a lamp that is marketed as a bug lamp and is designed to attract insects.
14. A black light lamp: a lamp that is marketed as a black light lamp and radiates predominantly ultraviolet light.
15. An infrared lamp: a lamp that is marketed as an infrared lamp and that emits more than 90 per cent of its radiation in the 0.7 µm to 10 µm range of the electromagnetic spectrum.
(6) For the purposes of this Schedule, a heritage building is a building or structure that satisfies one or more of the following criteria, or that is located on property that satisfies one or more of the following criteria:
1. The property is the subject of a covenant or agreement between the owner of the property and a conservation body, a government or a government agency and executed with the primary purpose of preserving, conserving and maintaining a cultural heritage feature or resource, or preventing its destruction, demolition or loss.
2. The property is listed in a register or inventory of heritage properties maintained by municipal, provincial or federal governments or government agencies.
3. The property is the subject of a municipal, provincial or federal commemorative or interpretive heritage plaque.
4. The property is part of a United Nations Educational, Scientific and Cultural Organization (UNESCO) World Heritage Site.
5. The property is included in the list of provincial heritage properties identified under Part III.1 of the Ontario Heritage Act that is maintained by the Ministry of Tourism, Culture and Gaming.
6. The property is designated under Part IV of the Ontario Heritage Act or is subject to a notice of intention to designate under Part IV of that Act.
7. The property is located within a heritage conservation district designated under Part V of the Ontario Heritage Act.
8. The property is subject to a Heritage Conservation District study area bylaw made under the Ontario Heritage Act.
9. The property is part of a national historic site of Canada set apart under the Canada National Parks Act, or is marked or commemorated under the Historic Sites and Monuments Act (Canada), or both.
10. The building or structure is designated as a heritage railway station under the Heritage Railway Stations Protection Act (Canada).
11. The building or structure is registered by the Federal Heritage Buildings Review Office as a classified or recognized heritage building.
(7) In this Schedule, a reference to a standard that contains an indication of a date in the name of the standard is a reference to the standard that was published on that date.
Read the ENERGY AND WATER EFFICIENCY — APPLIANCES AND PRODUCTS on e-Laws ↗
Made under Electricity Act, 1998, S.O. 1998, c. 15, Sched. A.