NOISE, O. Reg. 381/15
Section 1
Interpretation
Cite as NOISE, O. Reg. 381/15, s. 1 · current to November 11, 2026 · consolidated from July 1, 2016 · read from e-Laws on November 16, 2026
The text
(1) In this Regulation,
“attenuation” means a reduction in sound pressure level incident upon the ear; (“atténuation”)
“dBA” means a measure of sound level in decibels using a reference sound pressure of 20 micropascals when measured on the A-weighting network of a sound level meter; (“dBA”)
“decibel” means a unit of measurement of sound pressure level that is equal to 20 times the logarithm to the base 10 of the ratio of the pressure of a sound, divided by the reference pressure of 20 micropascals. (“décibel”)
(2) An equivalent sound exposure level is the steady sound level in dBA which, if present in a workplace for eight hours in a day, would contain the same total energy as that generated by the actual and varying sound levels to which a worker is exposed in his or her total work day.
(3) The equivalent sound exposure level is determined in accordance with the formula,
in which,
Lex,8 is the equivalent sound exposure level in 8 hours,
Σ is the sum of the values in the enclosed expression for all activities from i = 1 to i = n,
i is a discrete activity of a worker exposed to a sound level,
ti is the duration in hours of i,
SPLi is the sound level of i in dBA,
n is is the total number of discrete activities in the worker’s total workday.
Read the NOISE on e-Laws ↗