Designated substances, O. Reg. 490/09
Schedule 2
Cite as Designated substances, O. Reg. 490/09, Schedule 2 · current to November 11, 2026 · consolidated from July 1, 2026 · read from e-Laws on November 16, 2026
The text
Schedule 2 assigned protection factor for respirators
Type of Respirator | Assigned Protection Factor
Air-Purifying Respirator – filtering-facepiece | 10
Air-Purifying Respirator – half-facepiece | 10
Air- Purifying Respirator – full-facepiece | 50
Powered Air-Purifying Respirator – half-facepiece | 50
Powered Air-Purifying Respirator – full-facepiece | 1,000
Powered Air-Purifying Respirator – helmet/hood | 25 1,000 if supported by an SWPF study
Powered Air-Purifying Respirator – loose-fitting facepiece/visor | 25
Airline Respirator – continuous- flow half-facepiece | 50
Airline Respirator – continuous- flow full-facepiece | 1,000
Airline Respirator – continuous-flow helmet/hood | 25 1,000 if supported by an SWPF study
Airline Respirator – continuous-flow loose-fitting facepiece/visor | 25
Airline Respirator – pressure-demand half-facepiece | 50
Airline Respirator – pressure-demand full-facepiece | 1000
Self-Contained Breathing Apparatus (SCBA) – pressure-demand full-facepiece | 10,000
Multi-functional SCBA/Airline Respirator | 10,000
Read the Designated substances on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.