Designated substances, O. Reg. 490/09

Section 26.4

Requirements: tight-fitting respirator

Cite as Designated substances, O. Reg. 490/09, s. 26.4 · current to November 11, 2026 · consolidated from July 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) A respirator that is designed to be tight-fitting shall be tested for fit in accordance with one of the following: 1. A qualitative fit test. 2. A quantitative fit test. O. Reg. 189/19, s. 9. (2) A worker shall conduct positive and negative pressure user seal checks prior to every use of a tight-fitting elastomeric respirator. O. Reg. 189/19, s. 9. (3) A respirator that is designed to be tight-fitting shall not be provided to, or used by, a worker with facial hair that comes between the sealing surface of the facepiece and the face or that interferes with the functioning of the respirator. O. Reg. 189/19, s. 9.
Read the Designated substances on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.