Designated substances, O. Reg. 490/09

Section 26.2

Respirator requirements

Cite as Designated substances, O. Reg. 490/09, s. 26.2 · current to November 11, 2026 · consolidated from July 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) A respirator must meet the following requirements: 1. It must be, i. approved by NIOSH, ii. approved by CSA, or iii. approved by a testing and certification agency other than NIOSH or CSA and, in the opinion of a person qualified because of knowledge, training and experience in industrial hygiene practice, afford the worker using it protection at least equal to the protection afforded by the use of a respirator approved by NIOSH or CSA. 2. It must meet or exceed the applicable assigned protection factor set out in Schedule 2. O. Reg. 189/19, s. 9; O. Reg. 114/26, s. 2 (1). (2) An employer who provides a worker with a respirator shall have regard to the following when selecting the respirator: 1. The airborne concentration of the designated substance to which the worker is exposed, calculated in accordance with Part I of Schedule 1, and the maximum use concentration of the respirator. 2. The manufacturer’s information on the intended use, scope and limitations of the respirator. 3. The potential for an atmosphere with an oxygen concentration of less than 19.5 per cent, an IDLH atmosphere, or oil in the atmosphere. O. Reg. 189/19, s. 9. (3) If a respirator is used to protect a worker from exposure to asbestos, it must be, (a) equipped with a HEPA filter; or (b) equipped with a N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter. O. Reg. 189/19, s. 9; O. Reg. 114/26, s. 2 (2). (4) If an airline respirator is used in an IDLH atmosphere, it must be fitted with an auxiliary supply of breathing air that is sufficient to permit the worker to escape unassisted from the atmosphere. O. Reg. 189/19, s. 9. (5) If a respirator is supplied with breathing air from an air cylinder or a compressed breathing air system, the following requirements must be met: 1. The breathing air must meet the purity requirements set out in Table 1 of CSA Standard CAN/CSA-Z180.1-13 (R2018), Compressed Breathing Air and Systems (2018). 2. If a compressed breathing air system uses a compressor with an operating pressure greater than 103.4 kPa to supply the breathing air, the breathing air must be tested at least once every six months to ensure that it meets the requirement set out in paragraph 1. 3. The air intake used in connection with a compressed breathing air system must, i. for breathing air delivered by a compressor with an operating pressure greater than 103.4 kPa, be located in accordance with section 6 (Air intakes) and Annex A of CSA Standard CAN/CSA- Z180.1-13 (R2018), Compressed Breathing Air and Systems (2018), and ii. for breathing air delivered by an ambient air system, be located in accordance with section 6 (Air intakes) and Annex B of CSA Standard CAN/CSA-Z180.1-13 (R2018), Compressed Breathing Air and Systems (2018). 4. If a compressed breathing air system uses an oil-lubricated compressor to supply the breathing air, i. a continuous carbon monoxide monitor equipped with audible and visual alarms that activate at 5 ppm must be provided, and ii. the continuous carbon monoxide monitor must be calibrated in accordance with the manufacturer’s instructions. O. Reg. 189/19, s. 9.
Read the Designated substances on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.