fire code, O. Reg. 213/07

Section 9.9.3.7

Cite as fire code, O. Reg. 213/07, s. 9.9.3.7 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) Exterior exit stairways and fire escapes shall not serve floor areas above the sixth storey. (2) Unless otherwise approved, each fire escape used as an exit and each exterior exit stairway shall comply with Articles 3.4.7.2., 3.4.7.3., 3.4.7.5. and 3.4.7.6. of the 1994 Building Code. (3) Unless otherwise approved, exterior exit stairways, fire escapes and exterior exit passageways serving any storey above the second storey or any basement below the first basement shall be protected against fire exposure from the building in accordance with Sentences (4) and (5). (4) For the purposes of Sentence (3), window openings, except first storey display windows, shall be protected by wired glass in fixed steel frames if located within 3 storeys below, within 10 m below, within 1.8 m above or within 3 m horizontally of an exterior exit stairway, fire escape or exterior exit passageway. (5) For the purposes of Sentence (3), doorways and other openings shall be protected with closures having a fire-protection rating not less than 45 min if located within 3 storeys below, within 10 m below, within 1.8 m above or within 3 m horizontally of an exterior exit stairway, fire escape or exterior exit passageway. (6) Exterior exit stairways leading across roofs shall be provided with handrails on both sides of the walkway leading to the stairway at the edge of the roof, unless otherwise approved. (7) Exterior exit stairways and fire escapes below grade shall be (a) enclosed by side walls and a roof, with a door to ground level at the upper landing, (b) provided with a roof projecting horizontally for a distance of at least 1.8 m beyond any step or landing, or (c) provided with some other approved construction or device to prevent snow from accumulating in the stairway or fire escape. (8) Sentence (3) does not apply to an exterior passageway if (a) 50% or more of the exterior side of the passageway is open to the outdoors, (b) the exterior passageway floor assembly has a fire-resistance rating not less than 45 min or is of noncombustible construction, and (c) an exit stairway is provided at each end of the passageway. Door swing and hardware
Read the fire code on e-Laws ↗

Made under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4.