fire code, O. Reg. 213/07

Section 5.14.5.2

Cite as fire code, O. Reg. 213/07, s. 5.14.5.2 · current to November 11, 2026 · consolidated from January 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) Automobile undercoating materials shall have a flash point of not less than 37.8°C. (2) Where the flash point of an automobile undercoating is less than 60°C, it shall be applied in a work area where (a) there are no work pits, (b) there is a fan, that provides mechanical ventilation during the application, cleaning and drying cycles, (i) with nonferrous blades, or so constructed that a movement of the wheel or shaft will not permit two ferrous parts of the fan to rub or strike, and (ii) that ensures that the concentration of vapour does not exceed 25% of the lower explosive limit, (c) air movement from the air intake and exhaust system is along the length of the vehicle being undercoated, and (d) air is exhausted at a level approximately 1 m above the floor. Ignition sources
Read the fire code on e-Laws ↗

Made under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4.