(1) Drapes, curtains, netting and other similar or decorative materials, including textiles and films used in buildings, shall meet the requirements of CAN/ULC-S109, “Standard for Flame Tests of Flame-Resistant Fabrics and Films”, when these materials are used in any (a) care and treatment occupancy and detention occupancy, (b) lobby or exit, (c) access to exit in assembly occupancies, and assembly occupancies with an occupant load of more than 100 persons, or (d) an open floor area exceeding 1500 m2 in a business and personal services occupancy, mercantile occupancy or industrial occupancy, unless the floor area is divided into fire compartments each not exceeding 1500 m2 in area and each having a fire-resistance rating not less than 1 h. (2) Existing drapes, curtains, netting, and other similar or decorative materials, including textiles and films used in buildings which meet the requirements for a high degree of flame resistance as described in NOTE 4 of Test Method 27.1 of CAN2-4.2, “Textile Test Methods” are deemed to be in compliance with Sentence (1). (3) For the purposes of Sentence (2), “existing” means in place on November 21, 2007. Flameproofing treatments
Read the fire code on e-Laws ↗

Made under Fire Protection and Prevention Act, 1997, S.O. 1997, c. 4.