Designated Substance — asbestos on construction projects and in buildings and repair operations, O. Reg. 278/05
Section 26
Cite as Designated Substance — asbestos on construction projects and in buildings and repair operations, O. Reg. 278/05, s. 26 · current to November 11, 2026 · consolidated from July 1, 2026 · read from e-Laws on November 16, 2026
The text
Omitted (provides for coming into force of provisions of this Regulation). O. Reg. 278/05, s. 26.
Table 1 Bulk material samples
Subsection 3 (3)
Item | Type of material | Size of area of homogeneous material | Minimum number of bulk material samples to be collected
1. | Surfacing material, including without limitation material that is applied to surfaces by spraying, by troweling or otherwise, such as acoustical plaster on ceilings and fireproofing materials on structural members | Less than 90 square metres | 3
90 or more square metres, but less than 450 square metres | 5
450 or more square metres | 7
2. | Thermal insulation, except as described in item 3 | Any size | 3
3. | Thermal insulation patch | Less than 2 linear metres or 0.5 square metres | 1
4. | Other material | Any size | 3
Table 2 Respirators
Paragraph 12 of section 14 and paragraph 11 of section 15
Column 1 | Column 2
Work Category | Required respirator
Type 1 Operations
Worker requests that the employer provide a respirator to be used by the worker, as described in paragraph 12 of section 14 | Air purifying half-mask respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
Type 2 Operations
Work described in paragraph 1 of subsection 12 (3) | One of the following:
- Air purifying full-facepiece respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Powered air purifying respirator equipped with a tight-fitting facepiece (half or full-facepiece) and a high efficiency filter or N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Negative pressure (demand) supplied air respirator equipped with a full-facepiece
- Continuous flow supplied air respirator equipped with a tight fitting facepiece (half or full-facepiece)
Work described in paragraphs 2 to 7 and 9 to 11 of subsection 12 (3) | Air purifying half-mask respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
Breaking, cutting, drilling, abrading, grinding, | Material is not wetted | One of the following:
sanding or vibrating non-friable material containing asbestos by means of power tools, if the tool is | - Air purifying full-facepiece respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
attached to a dust collecting device equipped with a HEPA filter as described in paragraph 8 of subsection 12 (3) | - Powered air purifying respirator equipped with a tight-fitting facepiece (half or full-facepiece) and a high efficiency filter or N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Negative pressure (demand) supplied air respirator equipped with a full-facepiece
- Continuous flow supplied air respirator equipped with a tight fitting facepiece (half or full-facepiece)
Material is wetted to control spread of fibre | Air purifying half-mask respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
Type 3 Operations
Breaking, cutting, drilling, abrading, grinding, sanding or vibrating non-friable material containing | Material is not wetted | Pressure demand supplied air respirator equipped with a half mask
asbestos by means of power tools, if the tool is not attached to a dust collecting device equipped with a HEPA filter as described in paragraph 5 of | Material is wetted to control spread of fibre | One of the following:
subsection 12 (4) | - Air purifying full-facepiece respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Powered air purifying respirator equipped with a tight-fitting facepiece (half or full-facepiece) and a high efficiency filter or N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Negative pressure (demand) supplied air respirator equipped with a full-facepiece
- Continuous flow supplied air respirator equipped with a tight fitting facepiece (half or full-facepiece)
Work with friable material containing asbestos, as described in paragraphs 1 to 4 and 6 of subsection 12 (4) | Material is not wetted | Pressure demand supplied air respirator equipped with a full facepiece
Work with friable material, as described in paragraphs 1 to 4 and 6 of subsection 12 (4), that contains a type of asbestos other than chrysotile | Material was applied or installed by spraying, and is | Pressure demand supplied air respirator equipped with a half mask
Work with friable material, as described in | wetted to control | One of the following:
paragraphs 1 to 4 and 6 of subsection 12 (4), that contains only chrysotile asbestos | spread of fibre | - Air purifying full-facepiece respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Powered air purifying respirator equipped with a tight-fitting facepiece (half or full-facepiece) and a high efficiency filter or N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Negative pressure (demand) supplied air respirator equipped with a full-facepiece
- Continuous flow supplied air respirator equipped with a tight fitting facepiece (half or full-facepiece)
Work with friable material containing asbestos, as | Material was not | One of the following:
described in paragraphs 1 to 4 and 6 of subsection 12 (4) | applied or installed by spraying, and is | - Air purifying full-facepiece respirator with N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
wetted to control spread of fibre | - Powered air purifying respirator equipped with a tight-fitting facepiece (half or full-facepiece) and a high efficiency filter or N100, CA-N100, R100, CA-R100, P100 or CA-P100 particulate filter
- Negative pressure (demand) supplied air respirator equipped with a full-facepiece
- Continuous flow supplied air respirator equipped with a tight fitting facepiece (half or full-facepiece)
Table 3 Air Samples
Paragraph 4 of subsection 18 (6)
Minimum number of air samples to be taken from each enclosure | Area of enclosure
2 | 10 square metres or less
3 | More than 10 but less than 500 square metres
5 | 500 square metres or more
Read the Designated Substance — asbestos on construction projects and in buildings and repair operations on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.