Designated Substance — asbestos on construction projects and in buildings and repair operations, O. Reg. 278/05

Section 1

Definitions

Cite as Designated Substance — asbestos on construction projects and in buildings and repair operations, O. Reg. 278/05, s. 1 · current to November 11, 2026 · consolidated from July 1, 2026 · read from e-Laws on November 16, 2026

The text

(1) In this Regulation, “asbestos” means any of the fibrous silicates listed in subsection (2); (“amiante”) “asbestos-containing material” means material that contains 0.5 per cent or more asbestos by dry weight; (“matériau contenant de l’amiante”) “building” means any structure, vault, chamber or tunnel including, without limitation, the electrical, plumbing, heating and air handling equipment (including rigid duct work) of the structure, vault, chamber or tunnel; (“édifice”) “competent worker”, in relation to specific work, means a worker who, (a) is qualified because of knowledge, training and experience to perform the work, (b) is familiar with the Act and with the provisions of the regulations that apply to the work, and (c) has knowledge of all potential or actual danger to health or safety in the work; (“travailleur compétent”) “CSA” means the CSA Group; (“CSA”) “demolition” includes dismantling and breaking up; (“démolition”) “examine”, when used with reference to material, means to carry out procedures in accordance with section 3 to establish its asbestos content and to establish the type of asbestos, and “examination” has a corresponding meaning; (“examiner”) “friable material” means material that, (a) when dry, can be crumbled, pulverized or powdered by hand pressure, or (b) is crumbled, pulverized or powdered; (“matériau friable”) “HEPA filter” means a high efficiency particulate aerosol filter that is at least 99.97 per cent efficient in collecting a 0.3 micrometre aerosol; (“filtre HEPA”) “homogeneous material” means material that is uniform in colour and texture; (“matériau homogène”) “joint health and safety committee” means, (a) a joint health and safety committee established under section 9 of the Act, (b) a similar committee described in subsection 9 (4) of the Act, or (c) the workers or their representatives who participate in an arrangement, program or system described in subsection 9 (4) of the Act; (“comité mixte sur la santé et la sécurité”) “NIOSH” means the National Institute for Occupational Safety and Health; (“NIOSH”) “occupier” has the same meaning as in the Occupiers’ Liability Act; (“occupant”) “Type 1 operation” means an operation described in subsection 12 (2); (“opération de type 1”) “Type 2 operation” means an operation described in subsection 12 (3); (“opération de type 2”) “Type 3 operation” means an operation described in subsection 12 (4). (“opération de type 3”) O. Reg. 278/05, s. 1 (1); O. Reg. 115/26, s. 1. (2) The fibrous silicates referred to in the definition of “asbestos” in subsection (1) are: 1. Actinolite. 2. Amosite. 3. Anthophyllite. 4. Chrysotile. 5. Crocidolite. 6. Tremolite. O. Reg. 278/05, s. 1 (2).
Read the Designated Substance — asbestos on construction projects and in buildings and repair operations on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.