records of site condition — part XV.1 of the act, O. Reg. 153/04

Schedule E

Cite as records of site condition — part XV.1 of the act, O. Reg. 153/04, Schedule E · current to November 11, 2026 · consolidated from October 23, 2026 · read from e-Laws on November 16, 2026

The text

SCHEDULE E PHASE TWO ENVIRONMENTAL SITE ASSESSMENTS Part I Application Application and definitions 1. (1) The requirements in this Schedule apply to phase two environmental site assessments. (2) Each section in this Schedule is deemed to be a requirement, whether it is described as such or not. (3) In this Schedule, “in situ” means in place; “site investigation” means a site investigation that includes both a field investigation and a non-field investigation; “soil type” means soil texture class as determined pursuant to Figure 3.16 and Chapter 3 of the Soil Survey Manual, United States Department of Agriculture, Natural Resources Conservation Service, published at its website. Part II PLANNING Site INVESTIGATION Planning site investigation, specific objectives 2. The following are the specific objectives of the planning of the site investigation component of a phase two environmental site assessment: 1. To plan an investigation that will achieve the general objectives of a phase two environmental site assessment, i. through the use of an appropriate and complete information base concerning the phase two property, and ii. through the conduct of an investigation based both on information obtained before the phase two environmental site assessment begins and on the incorporation of information obtained during the phase two environmental site assessment. 2. To develop a sampling and analysis plan that will adequately assess all areas of the phase two property where contaminants may be present in land or water on, in or under the property. 3. To develop a quality assurance program that is designed to effectively limit errors and bias in sampling and analysis through implementation of assessment and control measures that will ensure data are useful, appropriate and accurate in the determination of whether the phase two property, or any RSC property within it, meets applicable site condition standards and any standards specified in a risk assessment. Planning site investigation, specific requirements 3. (1) The qualified person shall ensure the following requirements are met in planning a site investigation: 1. The phase one conceptual site model for the phase one environmental site assessment report shall be used in conjunction with other information in determining, i. media for investigation, ii. locations and depths for sampling, and iii. parameters for laboratory analysis. 2. Information obtained after the completion of the phase one environmental site assessment shall be used to modify the investigation, as appropriate. (2) The qualified person shall ensure that there is a sampling and analysis plan that includes a quality assurance and quality control program, data quality objectives, standard operating procedures and a description of any physical impediments that interfere with or limit the ability to conduct sampling and analysis. (3) The quality assurance and quality control program shall include the following requirements: 1. All non-dedicated sampling and monitoring equipment must be cleaned following each use. 2. Where ground water samples are to be analyzed for volatile organic compounds, one trip blank sample shall be submitted for laboratory analysis with each laboratory submission. 3. Specification of the minimum requirements for the number, type and frequency of field quality control measures including, i. trip blanks, ii. field duplicates, and iii. calibration checks on field instruments. 4. Sufficient field duplicate samples shall be collected in each medium being sampled, so that at least one field duplicate sample can be submitted for laboratory analysis for every ten samples submitted for laboratory analysis. 5. At least one field duplicate sample shall be submitted for laboratory analysis for every ten samples submitted for laboratory analysis. (4) The data quality objectives for all types of field data collected during the phase two environmental site assessment field investigation that set the level of uncertainty in environmental data shall be such that, (a) the decision-making is not affected; and (b) the overall objectives of the investigation are met. (5) Standard operating procedures shall be developed for all of the following field investigation methods used in the field investigation, (a) borehole drilling; (b) excavating; (c) soil sampling; (d) field screening measurements, including calibration procedures; (e) monitoring well installation; (f) monitoring well development; (g) field measurement of water quality indicators, including calibration procedures; (h) sediment sampling; and (i) ground water sampling. (6) The sampling and analysis plan shall include identification of and rationale and procedures for, (a) the choice of sampling system, such as a judgmental, random or grid sampling system; (b) the sampling media; (c) the number of samples; (d) sampling frequency; (e) sampling points; (f) sampling depth intervals, including the screened intervals of the monitoring wells; (g) other field information to be obtained, including water levels, field measurements and elevation surveying; and (h) samples to be submitted for laboratory analysis. (7) The sampling and analysis plan shall meet the following criteria: 1. The qualified person shall consider, i. findings as to potentially contaminating activity, ii. all contaminants of potential concern or appropriate subsets of such contaminants, and iii. any other information and matters relating to the environmental condition of the property which are relevant to an informed professional judgment. 2. After considering the matters referred to in paragraph 1, the qualified person shall determine, i. sampling and analysis for all contaminants of potential concern, or appropriate subsets of such contaminants, and ii. appropriate sampling and analysis for any other relevant contaminants. Soil vapour investigations 4. (1) Where a site investigation is to include a soil vapour investigation, the requirements of this Part apply, with necessary modifications. (2) Without limiting the generality of subsection (1), (a) when soil vapour samples are to be analyzed for volatile contaminants, including volatile organic compounds, one trip blank sample shall be submitted for laboratory analysis with each laboratory submission; (b) sufficient field duplicate samples of soil vapour shall be collected so that at least one field duplicate sample can be submitted for laboratory analysis for every ten samples submitted for laboratory analysis; (c) at least one field duplicate sample of soil vapour shall be submitted for laboratory analysis for every ten samples submitted for laboratory analysis; and (d) in addition to the standard operating procedures referred to in subsection 3 (5), standard operating procedures shall be developed for soil vapour probe installation and soil vapour probe development, performance, leak testing and purging and sampling. Part IIi CONDUCTING THE Site INVESTIGATION General Site investigation, specific objectives 5. The following are the specific objectives of the site investigation component of a phase two environmental site assessment: 1. To determine what applicable site condition standards apply to the phase two property. 2. To confirm whether contaminants are present on, in or under the phase two property, and, if so, what the contaminants are, where they are located on, in or under the phase two property and at what concentrations. 3. To determine whether any contaminants on, in or under the phase two property are present at concentrations higher than applicable site condition standards by, i. investigating and characterizing soil, ground water and sediment on, in or under the phase two property, and ii. taking measures to further investigate and characterize the soil, ground water and sediment following any actions taken to reduce the concentration of contaminants on, in or under the phase two property. 4. To determine whether any contaminants on, in or under the phase two property are present at concentrations higher than the standards specified in the risk assessment for the contaminants, where a risk assessment has been accepted with respect to contaminants on, in or under the phase two property, by, i. investigating and characterizing soil, ground water and sediment on, in or under the phase two property, and ii. taking measures to further investigate and characterize the soil, ground water and sediment following any actions taken to reduce the concentration of contaminants on, in or under the phase two property. Sampling and analysis of ground water 6. (1) The qualified person shall, in any of the following circumstances, ensure that the site investigation includes investigation, sampling and analysis of ground water on, in or under the phase two property in accordance with the requirements of this Schedule for the purpose of ensuring the objectives specified in paragraphs 2, 3 and 4 of section 5 of this Schedule in respect of ground water are achieved: 1. The phase two property is an enhanced investigation property. 2. The qualified person is of the opinion that it is necessary to conduct the investigation, sampling and analysis of ground water to make the required certifications in a record of site condition, to comply with the requirements of Part VIII of the regulation and this Schedule and to achieve the general and specific objectives of a phase two environmental site assessment. 3. Subject to subsection (2), there is insufficient soil on, in or under the phase two property to investigate, sample and analyse the concentration of contaminants in the soil in a manner that complies with the requirements of this Schedule and achieves the general and specific objectives of a phase two environmental site assessment. (2) Paragraph 3 of subsection (1) does not apply in respect of a phase two property if the following criteria are met: 1. The phase two property does not include land that is within 30 metres of a water body. 2. The phase two property, and all other properties located, in whole or in part, within 250 metres of the boundaries of the property, are supplied by a municipal drinking water system, as defined in the Safe Drinking Water Act, 2002. 3. The phase two property is not located in an area designated in a municipal official plan as a well-head protection area or other designation identified by the municipality for the protection of ground water. 4. The phase two property, or one of the properties in the phase one study area, does not have a well used or intended for use as a source of water for human consumption or agriculture. 5. The owner of the phase two property has not submitted or does not intend to submit a risk assessment under section 168.5 of the Act. 6. As part of the phase one environmental site assessment, the qualified person has investigated and assessed the potentially contaminating activities in the phase one study area and confirmed that there are no potentially contaminating activities or other sources of contaminants in the phase one study area that could result in an area of potential environmental concern at the phase two property due to contamination of ground water. 7. As part of the phase two environmental site assessment, i. sufficient investigation, sampling and analysis of the soil was undertaken to identify all contaminants of concern, ii. the qualified person, as part of the investigation and having regard to section 21 of this Schedule, used all reasonable efforts to determine the maximum concentration of contaminants in the soil on, in or under the phase two property, iii. if a contaminant of potential concern identified during the phase one environmental site assessment included a volatile organic compound or petroleum hydrocarbons F1, the investigation included the sampling and analysis of the soil for that contaminant in accordance with the requirements of this Schedule and the investigation found no exceedance of any of the applicable site condition standard for that contaminant, and iv. the soil sampled and analysed that exceeded an applicable site condition standard was not in contact with the water table. 8. During the site investigation and any excavation of the soil at the phase two property, no evidence of free product was observed on, in or under the property. 9. The qualified person is satisfied that contaminants have not migrated to the ground water on, in or under the phase two property, based on the phase one environmental site assessment, the phase one conceptual site model, the investigation, sampling and analysis of contaminants in soil undertaken as part of the phase two environmental site assessment, the phase two conceptual site model and any other supporting information and rationale documented by the qualified person in the phase two environmental site assessment report. 10. The qualified person is satisfied that it is not necessary to undertake the investigation, sampling and analysis of ground water as part of the phase two environmental site assessment for the qualified person to conclude that the applicable site condition standards are met on, in or under the phase two property and to make the required certifications to submit for filing a record of site condition in respect of the property. Delineation, General Site investigation, delineation 7. (1) The qualified person shall ensure that all areas on, in or under the phase two property where a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant shall be delineated laterally and vertically for each contaminant present in soil, ground water or sediment on, in or under the phase two property. (2) The qualified person shall ensure that all areas on, in or under the phase two property where a contaminant is present at a concentration greater than the standard specified in the risk assessment for the contaminant shall be delineated laterally and vertically for each contaminant present in soil, ground water or sediment on, in or under the phase two property for which a standard has been specified in a risk assessment that has been accepted by the Director. (3) The qualified person shall ensure the lateral and vertical delineations referred to in subsections (1) and (2) are undertaken, as appropriate in the circumstances, (a) during the investigation and characterization of contaminants on, in or under the phase two property; or (b) following any actions taken to reduce the concentration of contaminants on, in or under the phase two property. (4) The qualified person shall ensure that during the delineations referred to in subsections (1) and (2), (a) samples of each medium being investigated are collected from depths and locations on, in or under the phase two property and analyzed for contaminants, until it is determined that samples have been collected from the areas of highest concentration of contaminants on, in or under the phase two property; (b) areas of highest concentration of each contaminant in each medium being investigated on, in or under the phase two property are identified and located; and (c) the delineation is conducted by assuming the lateral and vertical extent of the area in which a contaminant is present at a concentration greater than the applicable site condition standard for that contaminant extends laterally or vertically, as the case may be, from a sampling location at which the contaminant is present at a concentration greater than the applicable site condition standard for the contaminant to the next sampling location at which the concentration of the contaminant is equal to or below the applicable site condition standard for the contaminant. (5) The qualified person shall ensure that the depth and thickness of sediments on, in or under the phase two property where a contaminant is present at concentrations greater than the applicable site condition standard or standard specified in a risk assessment, as the case may be, is determined for the contaminant while the presence of contaminants in sediment is being considered during the delineations referred to in subsections (1) and (2). (6) This section does not apply in respect of a phase two property if the criteria set out in subsection 6 (2) of this Schedule are met. Non-standard delineation 7.1 If the Director has accepted a risk assessment relating to the phase two property, a qualified person may, instead of complying with clause 7 (4) (c) of this Schedule, conduct a non-standard delineation in accordance with the following rules: 1. The delineation must be conducted in accordance with all requirements of section 7 of this Schedule, other than clause 7 (4) (c). 2. All contaminants of concern on, in or under the phase two property must be identified. 3. For each contaminant of concern found on, in or under the phase two property, the investigation must demonstrate that appropriate steps have been taken to locate the maximum concentration. 4. The qualified person must be satisfied that additional efforts to delineate the contaminants of concern are unlikely to contribute any further significant or meaningful information regarding the interpretation of the distribution and extent of contaminants on, in or under the phase two property. Field Investigation Equipment, Methods and Requirements Ground water sampling methods, general requirements 8. For a ground water sampling method to be used to characterize contamination or determine if the concentration of a contaminant is above, at or below an applicable site condition standard or standard specified in a risk assessment for the contaminant, the following requirements shall be met: 1. Sampling depth intervals, including the screened intervals of monitoring wells shall be positioned, i. within the geologic formation in which a contaminant may be present, ii. so as to isolate the zones where contaminants may be present, and iii. so as to delineate both dissolved and separate phase contaminants. 2. Where petroleum hydrocarbons or light non-aqueous phase liquids may be present on, in or under the phase two property, sampling depth intervals, including screened intervals of monitoring wells, shall be positioned to intersect the water table. 3. Where a monitoring well is being used, monitoring well screens shall not exceed 3.1 metres in length, based on the saturated length of the screen. 4. Revoked: O. Reg. 179/11, s. 8 (3). Requirements where sampling re meeting standards 9. (1) If the site investigation includes investigation, sampling and analysis of ground water and sampling of ground water is being undertaken to demonstrate if the applicable site condition standard for a contaminant has been met or not, the following requirements shall be followed: 1. Samples shall be collected from a monitoring well or equivalent professionally acceptable ground water collection method, and not from a test pit, excavation, borehole, undeveloped monitoring well, or any other similar source. 2. A monitoring well from which a sample is to be collected shall have been developed to remove any fluids that may have been introduced into the well during drilling and to remove particulates that may have become entrained in the well and filter pack. 3. A monitoring well from which a sample is to be collected shall have been appropriately purged immediately prior to sampling. 4. Precautions shall be taken to minimize the potential for cross-contamination or contamination through preferential pathways. (2) The qualified person shall ensure that the well development and purging referred to in paragraphs 2 and 3 of subsection (1) shall be documented by, (a) recording, (i) the date of the development or purging, (ii) the time the development or purging started and stopped, and (iii) the volume of fluid removed from the well during development or purging; (b) recording a rationale for concluding the development or purging was complete; and (c) recording a description of the measures taken to minimize cross contamination between wells when using non-dedicated equipment. Limitation on use of measurements taken by field screening equipment 10. Measurements taken by field screening equipment shall not be used to demonstrate that the applicable site condition standard or standard specified in a risk assessment for a contaminant have been met on, in or under the phase two property. Following standard operating procedures 11. (1) The standard operating procedures referred to in subsection 3 (5) shall be followed during the field investigation. (2) A qualified person or person supervised by a qualified person may deviate from standard operating procedures as appropriate, but the qualified person shall ensure that there is a professional rationale for any deviation. (3) The qualified person shall ensure that the standard operating procedures and any deviations from them, with a rationale for any deviation, used during the phase two environmental site assessment field investigation are documented in a manner that is sufficient to allow a third party to review the adequacy of the methods used. Identification and investigation of aquifers and aquitards 12. The qualified person shall ensure that all aquifers and aquitards on, in or under a phase two property which are relevant for determining the location and concentration of contaminants are identified and investigated. Sampling Location and Sampling Point Requirements Sampling points, soil and ground water 13. The qualified person shall ensure the following is taken into account when sampling points are being determined for soil and ground water during the field investigation: 1. The sampling and analysis plan. 2. Any new information about areas of potential environmental concern, contaminants and geologic and hydrogeologic conditions identified during the investigation up to the time of sampling. 3. The phase one conceptual site model from the phase one environmental site assessment. 4. The objectives and requirements of the site investigation. Sampling points, sediment 14. The qualified person shall ensure, in addition to the matters outlined in section 13, that the following is taken into account when sampling points for sediment are being determined during the course of the field investigation: 1. The size of the sampling area. 2. The location of depositional areas. 3. New information about areas of potential environmental concern, contaminants and geologic and hydrologeological conditions identified during the field investigation. Sampling locations, sediment 15. (1) The qualified person shall ensure that sediment samples are collected for all contaminants expected to be present on, in or under the phase two property and from locations on, in or under the phase two property that are most likely to have the contaminants present at concentrations above the applicable site condition standards. (2) The sampling done under subsection (1) shall be based on the applicable criteria set out in section 14. Sampling requirements where contaminant present above applicable standards 16. If at any time during the phase two field investigation a ground water sample is collected and analyzed for a contaminant and the analysis shows the contaminant is present at a concentration greater than the applicable site condition standard for the contaminant, the qualified person shall ensure that, (a) ground water samples are collected cross-gradient and down-gradient from the sampling point from which the ground water sample showing the concentration was collected; (b) the sample collected from each of the additional cross-gradient and down-gradient sampling points are submitted for laboratory analysis; and (c) the samples are analyzed for each contaminant that was shown to be present at a concentration greater than the applicable site condition standard for the contaminant, and for any other associated or related contaminants. Collecting, Handling and Analyzing Samples Soil samples, requirements 17. The qualified person shall ensure that the following requirements concerning soil sampling are met: 1. Soil samples for characterization or delineation shall be collected from undisturbed soils on, in or under the phase two property and not from soil which has been excavated, unless delineation is being undertaken after completion of actions to reduce the concentration of contaminants in which case soil samples shall be collected both from undisturbed soils on, in or under the phase two property and from stockpiles of soil which is intended to remain on the property permanently. 2. Soil samples shall be collected using professionally acceptable soil collection methods. 3. Precautions shall be taken to minimize the potential for cross-contamination or contamination through preferential pathways. 4. Grain size analysis shall be undertaken by a laboratory whenever a standard for fine-medium textured soil is to be applied. Soil sampling and analysis 18. The qualified person shall ensure that the number of samples of soil collected and analyzed is sufficient to determine the subsurface stratigraphy at or under the phase two property and the location of contaminants in soil, on, in or under the phase two property. Sediment samples 19. The qualified person shall ensure that for sediment samples a record is made of the depth at which each sample was collected and of the depth interval each sample is intended to represent. Contaminant not listed 20. Where a contaminant is identified on, in or under the phase two property during the site investigation and the contaminant is one for which there is no standard listed in the Soil, Ground Water and Sediment Standards, samples of the contaminant shall be collected and analyzed if the contaminant is a contaminant of concern. Selecting Samples for Analysis Selecting soil samples for analysis 21. The qualified person shall ensure the following are considered when soil samples to be analyzed are being selected in order to ensure the samples analyzed are representative of the maximum concentration of a contaminant in each area of the phase two property to be investigated: 1. Any evidence of the presence of a contaminant. 2. The maximum concentrations of a contaminant, i. measured using field screening equipment, and ii. any other field screening means which may be necessary to ensure the analysis includes such maximum concentrations. Measuring Ground Water Levels and Determining Ground Water Flow Direction Variation in ground water level 22. (1) If the site investigation includes investigation, sampling and analysis of ground water, the qualified person shall ensure that measuring ground water levels and determining ground water flow direction is undertaken during the site investigation and that this includes consideration of, (a) temporal ground water level variations on, in or under the phase two property; and (b) whether and how such variations may affect the distribution and concentration of contaminants in the ground water. (2) The measurement and determination referred to in subsection (1) shall be carried out at the times and places needed, but shall be included whenever ground water sampling is undertaken. Ground water flow directions 23. (1) When ground water flow directions are being determined pursuant to section 22, the qualified person shall ensure this is done through an assessment that includes, (a) measuring water levels to interpret ground water flow directions in any aquifer that is on, in or under a phase two property and in which a contaminant may be present at a concentration above the applicable site condition standard for the contaminant; (b) using water level measurements that are representative of static and actual conditions; (c) taking into account all water level measurements made when ground water samples have been collected; (d) determining the direction of interpreted ground water flow in each aquifer investigated; (e) assessing the potential for temporal variability in ground water flow direction; (f) determining a reference elevation for each monitoring well reported to the nearest centimetre relative to a geodetic or permanent and recoverable benchmark; (g) measuring water levels in a monitoring well at least 24 hours after the development of the well; (h) determining the ground water elevation of each aquifer in which water level measurements were taken; (i) installing a minimum of three monitoring wells, not placed in a straight line, in each aquifer to be investigated, at locations and in a manner appropriate to interpret horizontal flow directions; (j) determining horizontal hydraulic gradients for each aquifer; and (k) taking water level measurements whenever ground water samples are collected from a monitoring well, and at such other times as may be necessary to determine ground water flow direction and temporal ground water level variations. (2) The qualified person shall ensure that the following measures are undertaken where a phase two property is one at which petroleum hydrocarbons, light non-aqueous phase liquids, volatile contaminants, including volatile organic compounds, or dense non-aqueous phase liquids may be present on, in or under the property: 1. Testing each monitoring well with an interface probe to determine if light or dense non-aqueous phase liquids are present in the well. 2. Where light or dense non-aqueous liquids are present, measuring the thickness of such free product and including the measurement in determining water levels and measuring and interpreting ground water flow directions. Documenting the Field Investigation Finalized field logs, soil 24. (1) The qualified person shall ensure that field logs are recorded and finalized for all intrusive investigation points and test holes in the field investigation to document the soil conditions on, in or under the phase two property. (2) A finalized field log shall include, (a) a unique identification number; (b) the date; (c) a description of type and condition of geologic material encountered; (d) a description of type and condition of other material encountered; (e) the soil colour; (f) the soil vapour measurement from field screening for volatile contaminants, including volatile organic compounds; (g) the soil moisture content, using a qualitative description; (h) the observations concerning the soil; (i) the identification of soil samples sent for laboratory analysis; (j) the soil sample depths; (k) the soil sampling methods; (l) evidence of free flowing product; (m) the total depth drilled; and (n) any drilling refusal. Monitoring wells and test holes, finalized field logs 25. (1) If the site investigation includes investigation, sampling and analysis of ground water, the qualified person shall ensure that field logs are recorded and finalized for all monitoring wells and test holes constructed during the field investigation to document the ground water conditions on, in or under the phase two property. (2) A finalized field log for a monitoring well shall include, (a) the surveyed location and elevation of the well; (b) the monitoring well identification number; (c) the details of the well construction, including screened interval, sand pack, seal location and thickness, well diameter and screen slot size; (d) the date; (e) the total depth drilled; and (f) any drilling refusal. Sediment sampling, finalized field logs 26. (1) The qualified person shall ensure that field logs are recorded and finalized for all sediment sampling during the field investigation to document the presence of contaminants on, in or under the phase two property that may be present at concentrations above the applicable site condition standards. (2) A finalized field log for sediment shall include, (a) a unique sample identification number; (b) the date; (c) the sediment type, for example gravel, sand, silt, clay or organic, or types, if different sediment types appear at different depths; (d) the sediment colour or colours, if different sediment colours appear at different depths; (e) the mixing layer depth; (f) a description of bottom dynamics where samples are collected; (g) the sediment moisture content, using a qualitative description; (h) any significant observations concerning the sediment; (i) the identification of sediment samples sent for laboratory analysis; (j) the sediment sample depths; (k) the sediment sampling methods; (l) evidence of free flowing product or strong chemical odour; and (m) the presence or absence of aquatic biota in the sediment. Soil Vapour Investigation Requirements Soil vapour investigation requirements, general 27. (1) The qualified person shall ensure that the requirements that apply to an investigation of soil vapour that is being undertaken as part of a site investigation at a phase two property are met. (2) The requirements of this Schedule apply, with necessary modifications and subject to sections 28 and 29 to the conduct of a soil vapour investigation at a phase two property. Limitation on use of measurements taken by field screening equipment 28. Measurements taken by field screening equipment shall not be used to determine the soil vapour concentration of a contaminant on, in or under the phase two property. Soil vapour probes, finalized field logs 29. (1) The qualified person shall ensure that field logs are recorded and finalized for all soil vapour probes constructed during the field investigation to document the subsurface conditions on, in or under the phase two property. (2) In addition to the information entered into the field log with respect to soil samples under section 24, a finalized field log for a soil vapour probe shall include, (a) the location and elevation of the well or probe; (b) the identification number; and (c) the details of the soil vapour probe construction, including screened interval, sand pack, seal location and thickness, soil vapour probe diameter and screen slot size. Excess Soil Brought to the Phase Two Property Specific objective 30. The specific objective of the requirements concerning excess soil brought to the phase two property for final placement is to ensure that the concentration of contaminants in the soil does not exceed the applicable soil quality standards, as determined in accordance with the Excess Soil Standards. Requirements for excess soil 31. (1) The qualified person shall ensure that before any excess soil is brought to a phase two property for final placement, the concentration of any contaminants in the excess soil is known by complying with the following sampling and analysis requirements: 1. Samples of the excess soil shall be collected, i. by the qualified person, or ii. under the supervision of the qualified person, by an individual qualified to take the samples. 2. The qualified person shall prepare a plan respecting: i. The collection of representative samples at locations and frequencies that will be adequate to allow for, A. the concentrations of any contaminants in the soil to be known, and B. whether any contaminants are present in the soil as a result of any potentially contaminating activity or other environmental condition that occurred while the excess soil was at the source property, while the excess soil was being stored at any property and while the excess soil was being handled, stored or transported at any time before its final placement on, in or under the phase two property. ii. The selection of samples for analysis so as to obtain representative results that locate any areas in the soil being sampled where any contaminant may be present at a concentration greater than the applicable soil quality standard, as determined in accordance with the Excess Soil Standards. 3. The samples shall be collected in accordance with the plan mentioned in paragraph 2. 4. The samples shall be handled and analysed in accordance with section 47 of the regulation and shall be analysed for contaminants that may reasonably be expected to be present in the excess soil, having regard to the following: i. The source property. ii. The handling of the excess soil, including its storage and transport, following its original excavation. iii. Any other relevant factors, including potentially contaminating activity. 5. At least one sample shall be analyzed for each 160 cubic metres of soil for the first 5,000 cubic metres to be assessed at each source property from which soil is being brought to the phase two property, following which at least one sample for each additional 300 cubic metres of soil which is to remain on, in or under the phase two property shall be analyzed. (2) Despite paragraphs 1 to 5 of subsection (1), the requirements set out in those paragraphs may be satisfied by carrying out a sampling and analysis plan and soil characterization report that is part of a sampling and analysis plan and soil characterization report prepared under Ontario Regulation 406/19 (On-Site and Excess Soil Management) made under the Act in respect of the excess soil that is to be brought to the phase two property. 32.-34. Revoked: O. Reg. 407/19, s. 26 (2). Soil Excavated at the Phase Two Property Specific objective 34.1 The specific objective of the requirements concerning soil excavated at the phase two property for possible reuse there is to determine reliably, (a) whether the applicable site condition standards or any standard specified in a risk assessment with respect to the property, for all contaminants in the soil have been met; and (b) whether, when the soil is reused at the phase two property, the property meets the applicable site condition standards or any standard specified in a risk assessment. Segregation of soil excavated from or under the phase two property 35. (1) The qualified person shall ensure that soil excavated from or under the phase two property during the phase two field investigation or in the course of remediation, and not removed from the phase two property as part of the excavating but placed in stockpiles for possible reuse on, in or under the phase two property, shall be segregated in separate stockpiles on or above the phase two property according to contaminant and concentration of contaminant. (2) Decisions on how to segregate excavated soil referred to in subsection (1) shall be based on the results of any one or more of, (a) in situ characterization; (b) field screening; (c) sample collection and analysis; and (d) indications of contamination. Sampling and analysis of soil in stockpiles 36. The qualified person shall ensure that where excavated soil referred to in subsection 35 (1) is intended for reuse on, in or under the property, the soil shall be sampled and analyzed as follows, before it is reused: 1. Samples of the excavated soil from each stockpile to be reused shall be collected and analyzed so as to characterize the contaminants present in the excavated soil. 2. Samples must be selected for analysis and contaminants chosen for analysis on the basis of all available information, including the phase one environmental site assessment and subsequently obtained information and must include analysis for any contaminants which may have been introduced to, brought onto, released to or created in land and water on, in or under the phase two property during actions taken to reduce the concentration of contaminants. 3. Sampling locations must be chosen so as to ensure uniformly distributed and representative sampling collection throughout the stockpile. 4. Samples must not be collected from the surface of a stockpile. 5. Samples of soil from stockpiles must be collected and analyzed by an accredited laboratory, at or above the applicable minimum frequencies set out in Table 2 of this Schedule. 6. If the stockpile volume is greater than 5000 m3, the minimum number of samples that must be collected and analysed as described in paragraph 5 is the amount determined in accordance with the following formula: N = 32 + (V − 5000) ÷ 300 Where, N = the minimum number of samples, and V = the stockpile volume in cubic metres. Actions Taken to Reduce the Concentration of Contaminants Required precautionary measures during remediation 37. The qualified person shall ensure that the following precautionary measures are undertaken before and during remediation of the phase two property: 1. Before remediation is undertaken, the steps necessary to establish baseline and background conditions relevant to the proposed remediation method are taken to a degree that is adequate to detect any increases of contaminants on, in or under the phase two property following remediation, including contaminants created or introduced to the property during remediation. 2. Sampling of appropriate monitoring wells and analysis of ground water samples occurs for appropriate contaminants, including contaminants created or introduced to the property during remediation. Free flowing product 38. The qualified person shall ensure that the volume of any free flowing product removed from ground water on, in or under the phase two property is monitored and recorded. Confirmation Sampling and Analysis Objectives of confirmation sampling and analysis 39. (1) The specific objectives of confirmation sampling and analysis are the following: 1. To confirm the effect and effectiveness, if any, of remediation undertaken to reduce the concentration of contaminants on, in or under the phase two property. 2. To provide a reliable basis for conclusions as to whether the applicable site condition standards or standards specified in a risk assessment have or have not been met for each contaminant. 3. To identify and demonstrate the location and concentration of contaminants on, in or under the phase two property following the completion of remediation undertaken to reduce the concentration of contaminants on, in or under the phase two property. (2) This section does not apply in respect of a phase two property if the criteria set out in subsection 6 (2) of this Schedule are met. Requirements for confirmation sampling and analysis 40. (1) The following requirements apply to confirmation sampling and analysis: 1. Confirmation sampling and analysis shall be undertaken during and following actions taken to reduce the concentration of contaminants on, in or under the phase two property. 2. The requirements of this Schedule and sections 47 and 48 of the regulation applicable to the collection and recording of samples of soil, ground water or sediment and the methods of sampling, analysis of samples and reporting of analytical results apply to confirmation samples. 3. When actions intended to reduce the concentration of contaminants on, in or under the phase two property are to be taken, the qualified person shall, i. design and implement a sampling and analysis program to collect samples and analyze them from all locations where remediation was undertaken, ii. ensure samples are collected and analyzed for each contaminant in any area and medium where the contaminant was present at a concentration greater than the applicable site condition standard or standard specified in a risk assessment for the contaminant before remediation, where the soil, ground water or sediment remains on, in or under the phase two property after remediation, and iii. ensure samples are collected and analyzed for each contaminant where soil, ground water or sediment has been returned to the phase two property after remediation at a location away from the phase two property. 4. The confirmation sampling and analysis program shall be designed and conducted so as to demonstrate whether the phase two property and any property under it meets or does not meet the applicable site condition standards or any standard specified in a risk assessment for all contaminants of concern. 5. Confirmation sampling shall be conducted at locations and depths which include those areas on, in or under the phase two property, where a contaminant was present, before remediation, at a concentration greater than the applicable site condition standard or any standard specified in a risk assessment for the contaminant and the maximum concentration of the contaminant in the area was located. 6. Samples taken from monitoring wells into which material was introduced into the monitoring well for purposes of remediation shall not be used to meet the objectives of confirmation sampling, including being used as evidence to demonstrate that the phase two property meets the applicable site condition standard or any standard specified in a risk assessment for a contaminant. 7. Where part of the soil on, in or under a phase two property has been excavated the qualified person shall ensure that, i. confirmation samples of soil are collected from each wall and floor of the excavation and analyzed in order to demonstrate that the limits of the excavation are appropriate and that the excavation has included all areas where a contaminant may be present at a concentration greater than the applicable site condition standard or any standard specified in a risk assessment, and ii. the number and location of samples at each excavation is equal to or greater than the minimum requirements set out in Table 3 of this Schedule or, where the floor area of the excavation is greater than 1,000 square metres, is adequate to meet the requirements of subparagraph i, is greater than the number and location requirements in Table 3 for a floor area of between 750 to 1,000 square metres, and follows the guidance in Note 1 to Table 3. 8. Where a contaminant is present in ground water on, in or under a phase two property at a concentration greater than the applicable site condition standard for the contaminant or any standard specified in a risk assessment for the contaminant which has been accepted under clause 168.5 (1) (a) of the Act, and actions have been taken on, in or under the phase two property to reduce the concentration of the contaminant to meet the standard which applies to the contaminant in the circumstances, the qualified person shall ensure that, i. confirmation sampling of ground water is conducted, in each area where the actions occurred or to which material was returned following remediation at a location away from the property as follows: A. where the remediation is in situ remediation, until the results from analysis of samples collected from four consecutive quarterly sampling events, the first of which is conducted a minimum of 90 days after the last remedial action, are for all contaminants analyzed below the applicable site condition standards or, where applicable, any standards specified in a risk assessment, and B. where the remediation is not remediation described in sub-subparagraph A but is excavation on, in or under the phase two property, until the results from analysis of samples collected from two consecutive quarterly sampling events, the first of which is conducted a minimum of 90 days after the last remedial action, are for all contaminants analyzed below the applicable site condition standards or, where applicable, any standards specified in a risk assessment, and ii. the contaminants sampled and analyzed include all contaminants for which remediation was undertaken and any contaminants which may have been introduced to, created in or brought onto the land or water on, in or under the phase two property or released during remediation. 9. Where confirmation sampling is being undertaken pursuant to paragraph 8, the qualified person shall ensure that water level measurements are also taken in the monitoring wells from which the confirmation samples are being taken. (2) This section does not apply in respect of a phase two property if the criteria set out in subsection 6 (2) of this Schedule are met. Site Assessment Requirements for Risk Assessment Requirements for risk assessment 41. Where the owner of a phase two property wishes to submit a modified generic risk assessment, the qualified person shall ensure that in any case where in the risk assessment an assumed value for any assumption set out under an assumption category in Table 4 of this Schedule to be modified from the assumed value for the assumption used by the Ministry to develop the full depth generic site condition standards, an assessment is carried out which satisfies the minimum requirements and meets the objective set out in Table 4 with respect to that assumption category. Requirements of this Schedule 42. The requirements of this Schedule that are relevant to an objective or minimum requirement in Table 4 of this Schedule which must be met pursuant to section 41 apply, with necessary modifications, to the minimum requirement. Part iV Review and Evaluation of Information Review and evaluation of information 43. (1) The qualified person shall review, interpret and evaluate the information used in the planning of the site investigation and obtained from conducting the site investigation. (2) Based on the review, interpretation and evaluation, the qualified person shall prepare a phase two conceptual site model of the phase two property that demonstrates the current condition of the phase two property or, where remedial actions have been undertaken, the condition of the phase two property before the remedial actions were undertaken. (3) If the phase two property meets the criteria set out in subsection 6 (2) of this Schedule and that provision is being relied upon to exempt the property from the requirement to investigate, sample and analyse ground water under paragraph 3 of subsection 6 (1) of this Schedule, the qualified person shall include in the phase two conceptual site model of the phase two property a narrative description of the rationale for concluding that the investigation, sampling and analysis of ground water are unnecessary in order to conclude that the applicable site condition standards are met on, in or under the phase two property and to make the required certifications to submit for filing a record of site condition in respect of the property. (4) The qualified person shall include, for the purposes of the narrative description mentioned in subsection (3), a discussion of how the following factors and any other evidence were considered: 1. The types of potentially contaminating activities and sources of contaminants within the phase one study area. 2. The soil type and nature of the soil, such as effective porosity, grain size and permeability. 3. The nature of the bedrock, including primary and secondary porosity. 4. The approximate depth to the water table. 5. The approximate depth from the soil surface to bedrock before any excavation of soil from the phase two property. 6. The amount of soil removed from the phase two property and, of the soil that was removed, the amount that was exceeding the applicable site condition standards. 7. The pH value of the soil. 8. Having regard for the geochemical properties of contaminants of concern, the potential for those contaminants to leach from soil to ground water. 9. Any leachate testing results. 10. Any evidence that the concentration of contaminants sampled and analysed decreases as the depth of the soil increases. 11. Any indication of whether the excavation of soil at the phase two property went below the approximate depth of the highest water table. (5)-(9) Revoked: O. Reg. 407/19, s. 26 (6). (10) During the course of the phase two environmental site assessment or any subsequent phase one or phase two environmental site assessment of the phase two property or other site assessment work with respect to the phase two property, the qualified person shall update the review, evaluation and interpretation as further information becomes available. Part V Phase Two Environmental Site assessment Report Preparation of report 44. The qualified person shall ensure that a phase two environmental site assessment report which meets the requirements of this Part is prepared. Phase two environmental site assessment report, specific objectives 45. The following are the specific objectives of a phase two environmental site assessment report: 1. To document the presence or absence of contaminants in the land or water on, in or under the phase two property. 2. To document the determination of the location of one or more contaminants in the land or water on, in or under the phase two property. 3. To provide a record of a phase two environmental site assessment of the phase two property that demonstrates, in a manner that is clear and can be assessed and reconstructed, how the phase two environmental site assessment of the property was carried out, and, in particular, to document and demonstrate, i. how the general and specific objectives of a phase two environmental site assessment, including each of its components, were achieved and how the minimum requirements for the objectives were met, ii. to document the basis for certifications in a record of site condition as to whether all or that part of the phase two property that may comprise the RSC property meets the applicable site condition standards or standards specified in a risk assessment for one or more contaminants, and iii. to document information needed to undertake a risk assessment of the phase two property with respect to one or more contaminants. Phase two environmental site assessment report, general requirements 46. The phase two environmental site assessment report shall be based on the following: 1. Information obtained from planning and conducting the phase two environmental site assessment. 2. Interpretation and evaluation of the information from planning and conducting the phase two environmental site assessment. 3. Any additional information that the qualified person considers relevant. Phase two environmental site assessment report, general requirements 47. (1) The phase two environmental site assessment report shall, (a) be divided into the report sections as specified in Table 1 of this Schedule; and (b) include the headings and sub-headings set out in Table 1. (2) The phase two environmental site assessment report shall address the requirements set out in Table 1 of this Schedule. (3) The qualified person may include report sections, headings and sub-headings in addition to those set out in Table 1 of this Schedule and other information in the phase two environmental site assessment report. (4) The following sub-headings in Report Section 5 (Investigation Method) of Table 1 of this Schedule and the requirements associated with the sub-headings do not apply unless there has been sampling of ground water during the phase two environmental site assessment: 1. Ground Water: Monitoring Well Installation. 2. Ground Water: Field Measurement of Water Quality Parameters. 3. Ground Water: Sampling. (4.1) Sub-Heading (iii) (Soil: Sampling) in Report Section 5 (Investigation Method) of Table 1 of this Schedule and the requirements associated with the sub-heading do not apply unless there has been sampling of soil during the phase two environmental site assessment. (5) Sub-Heading (viii) (Sediment: Sampling) in Report Section 5 (Investigation Method) of Table 1 of this Schedule and the requirements associated with it do not apply unless there has been sampling of sediment during the phase two environmental site assessment. (6) The following sub-headings in Report Section 6 (Review and Evaluation) of Table 1 of this Schedule and the requirements associated with the sub-headings do not apply unless there has been sampling of ground water during the phase two environmental site assessment: 1. Ground Water: Elevations and Flow Direction. 2. Ground Water: Hydraulic Gradients. 3. Ground Water: Quality. (6.1) The following sub-headings in Report Section 6 (Review and Evaluation) of Table 1 of this Schedule and the requirements associated with the sub-headings do not apply unless there has been sampling of soil during the phase two environmental site assessment: (iv) Fine-Medium Soil Texture. (v) Soil: Field Screening. (vi) Soil Quality. (7) Sub-Heading (viii) (Sediment Quality) in Report Section 6 (Review and Evaluation) of Table 1 of this Schedule and the requirements associated with it do not apply unless there has been sampling of sediment during the phase two environmental site assessment. (8) The requirements in Report Section 9 (Figures and Tables) of Table 1 of this Schedule which refer to monitoring wells, ground water, ground water elevations or analytical results of ground water sampling do not apply unless there has been sampling of ground water during the phase two environmental site assessment. (9) The requirements in Report Section 9 (Figures and Tables) of Table 1 of this Schedule which refer to analytical results of sediment sampling do not apply unless there has been sampling of sediment during the phase two environmental site assessment. (9.1) The requirements in Report Section 9 (Figures and Tables) of Table 1 of this Schedule which refer to soil data or analytical results of soil sampling do not apply unless there has been sampling of soil during the phase two environmental site assessment. (10) The following requirements associated with Heading (c) (Soil Excavated at the Phase Two Property or Excess Soil Brought to the Phase Two Property) in Report Section 10 (Appendices) of Table 1 of this Schedule do not apply, unless the conditions in each paragraph are met: 1. Sub-Heading (i) (Excess Soil brought to RSC property) does not apply unless excess soil has been brought to the phase two property to remain there after the phase two environmental site assessment. 2. Sub-Heading (ii) (Segregation of Soil) does not apply unless soil has been excavated at the phase two property and placed in a stockpile for possible reuse at the phase two property. 3. Sub-Heading (iii) (Stockpiles) does not apply unless the soil in stockpiles is to be reused at the phase two property. (11) Heading (b) (Remediation) in Report Section 10 (Appendices) of Table 1 of this Schedule and the requirements associated with it do not apply where no remediation has been conducted. (12) The requirements under Heading (b) (Remediation) in Report Section 10 (Appendices) of Table 1 of this Schedule which refer to remediation of ground water do not apply unless there has been remediation of ground water during the phase two environmental site assessment. (13) Heading (d) (Modified Generic Risk Assessment) in Report Section 10 (Appendices) of Table 1 of this Schedule and the requirements associated with it do not apply where the owner does not intend to submit such a risk assessment. (14) The phase two environmental site assessment report must have the appendices, references and figures specified in Table 1 of this Schedule attached to the report. (15) Figures, maps, site plans and cross-sections in the phase two environmental site assessment report shall contain a scale, north arrow and a title block that includes, (a) a descriptive title; (b) the address, if any, of the phase two property; (c) the name of the qualified person’s firm, company or partnership, if any; and (d) the date the figure, map, site plan or cross-section was created. TABLE 1 MANDATORY REQUIREMENTS FOR PHASE two ENVIRONMENTAL SITE ASSESSMENT REPORTS Column 1 Report Section | Column 2 Heading | Column 3 Sub-Heading | Column 4 Minimum Requirements 1. Executive Summary | not applicable | not applicable | Provide a brief summary of the report. 2. Introduction | not applicable | (i) Site Description | Provide the following, i. municipal address and property identifier number, if any, of the phase two property, and ii. size and boundaries of the phase two property. 2. Introduction | not applicable | (ii) Property Ownership | Provide the name and address and other contact information for the owner of the phase two property and the name, status and other contact information for any other person who has engaged the qualified person to conduct the phase two environmental site assessment. 2. Introduction | not applicable | (iii) Current and Proposed Future Uses | Provide the identification of the current and proposed uses of the phase two property, and whether, if the proposed use is undertaken, section 168.3.1 of the Act would prohibit the new use unless a record of site condition is filed. 2. Introduction | not applicable | (iv) Applicable Site Condition Standard | Provide identification of and rationale for the choice of the applicable site condition standard for the phase two property, based on consideration of matters relevant to the choice, including sections 35, 41 and 43.1 of the regulation, the current and proposed use of the property, soil texture of the property and proposed grading of the property following adoption of the proposed use. 3. Background Information | not applicable | (i) Physical Setting | Provide a description of the general physical setting of the phase two property within the phase one study area, including, i. water bodies, ii. areas of natural significance, iii. the topography and surface water drainage features on the phase two property, iv. any well-head protection areas or other designation identified by the municipality in its official plan for the protection of ground water, and v. Observations related to whether the property and all other properties within the phase one study area are served by a municipal drinking water system, as defined in the Safe Drinking Water Act, 2002. vi. Where all properties within the phase one study area are served by a municipal drinking water system, observations related to the presence of any well on the phase two property or within the phase one study area that supplies water used for human consumption or an agricultural use. 3. Background Information | not applicable | (ii) Past Investigations | Provide, i. a summary of any relevant past investigations of the phase two property, and ii. documentation of the steps taken to confirm that information or data which are to be used from previous investigations are of adequate quality such that it can be relied upon. 4. Scope of the Investigation | not applicable | (i) Overview of Site Investigation | Provide an overview of the site investigation conducted with respect to the phase two property. 4. Scope of the Investigation | not applicable | (ii) Media Investigated | Provide, i. the rationale for whether to include in the field investigation sampling and analysis of each of ground water and sediment on, in or under the phase two property, and ii. an overview of the field investigation of each medium for which sampling and analysis were done. 4. Scope of the Investigation | not applicable | (iii) Phase One Conceptual Site Model | Provide a description of the phase one conceptual site model prepared as part of the phase one environmental site assessment report and of relevant subsequently acquired information. 4. Scope of the Investigation | not applicable | (iv) Deviations From Sampling and Analysis Plan | Provide a description of any deviations from the sampling and analysis plan. 4. Scope of the Investigation | not applicable | (v) Impediments | Provide a description of any physical impediments and documentation of any denial of access. 5. Investigation Method | not applicable | (i) General | Provide a brief description of all methods as specified in the following sections. Where the method differs from the associated standard operating procedure, provide a detailed description of the method used, and a rationale for the change in method. 5. Investigation Method | not applicable | (ii) Drilling and Excavating | Provide for each borehole drilled or test pit excavated, i. the name of the contractor, ii. a description of the equipment used, iii. a description of the measures taken to minimize the potential for cross-contamination, and iv. the frequency of sample collection. 5. Investigation Method | not applicable | (iii) Soil: Sampling | Provide, i. a description of all equipment used to collect soil samples, and ii. a geological description of soil and sediment cores and samples, based on the finalized field logs for each monitoring well, test hole or intrusive investigation point. 5. Investigation Method | not applicable | (iv) Field Screening Measurements | 1. Provide a description of any equipment used to perform field screening measurements including, i. make and model number, ii. chemicals the equipment can detect and associated detection limits, iii. precision of the measurements, iv. accuracy of the measurements, v. calibration reference standards such as span gas, and vi. procedures for checking calibration of the equipment. 2. Provide a description of how field screening measurements were used to select samples for laboratory analysis, if applicable. 3. Where a field screening method was different from what was proposed as a standard operating procedure in the sampling and analysis plan, provide a description of, and rationale for, the difference. 5. Investigation Method | not applicable | (v) Ground Water: Monitoring Well Installation | 1. For each monitoring well installed provide, i. the name of the contractor, ii. a description of the equipment used, iii. a description of the measures taken to minimize the potential for cross-contamination, and iv. the frequency of sample collection during drilling, if any. 2. Provide a description of the methods used to develop monitoring wells. 5. Investigation Method | not applicable | (vi) Ground Water: Field Measurement of Water Quality Parameters | Provide a description of the methods used to measure water quality parameters such as pH, specific conductance and temperature. 5. Investigation Method | not applicable | (vii) Ground Water: Sampling | Provide a description of the methods used to conduct ground water sampling. 5. Investigation Method | not applicable | (viii) Sediment: Sampling | Provide a description of the methods used to collect sediment samples. 5. Investigation Method | not applicable | (ix) Analytical Testing | Provide the names of all laboratories used for analysis of soil, sediment or ground water samples. 5. Investigation Method | not applicable | (x) Residue Management Procedures | Provide detailed documentation of procedures used for the management of residues from the field investigation including, i. soil cuttings from drilling and excavations, ii. water from well development and purging, and iii. fluids from equipment cleaning. 5. Investigation Method | not applicable | (xi) Elevation Surveying | Provide an accurate specification of the location of any benchmark used in surveying of elevations. 5. Investigation Method | not applicable | (xii) Quality Assurance and Quality Control Measures | Provide, i. a description of sample containers, preservation, labelling, handling and custody for samples submitted for laboratory analysis, including any deviations from the sampling and analysis plan, ii. a description of equipment cleaning procedures followed during all sampling, iii. a description of how the field quality control measures referred to in subsection 3 (3) were carried out, and iv. a description of, and rationale for, any deviations from the procedures set out in the quality assurance and quality control program set out in the sampling and analysis plan. 6. Review and Evaluation | not applicable | (i) Geology | Provide a description and analysis of each aquifer and aquitard investigated pursuant to section 12 including, i. estimated thickness of each geologic unit, ii. elevations, relative to a geodetic benchmark or other permanent and recoverable benchmark, of the top and bottom of each geologic unit, iii. geological and other material in each geological unit, iv. the properties of each aquifer and aquitard, and v. the rationale for the choice of aquifers and aquitards investigated as it relates to identification of the location, presence, release, concentration, migration or retention of a contaminant. 6. Review and Evaluation | not applicable | (ii) Ground Water: Elevations and Flow Direction | 1. Provide, i. a discussion of, and rationale for, locations and screened intervals of monitoring wells used for interpretations of ground water flow direction, ii. results of any measurements taken using an interface probe during water level measurements, and iii. measurements of the thickness of any free flowing product present in monitoring wells. 2. Provide a description of the method used to calculate ground water elevation in the monitoring well, including, i. a description of the ground water elevations from all monitoring events in any aquifer investigated, ii. a description of the interpreted direction of ground water flow at the phase two property, iii. assessment of the potential for temporal variability in ground water flow direction, and iv. an evaluation and description of the potential interaction between any buried utilities in or under the phase two property and the water table. 6. Review and Evaluation | not applicable | (iii) Ground Water: Hydraulic Gradients | Provide, i. a description of the horizontal hydraulic gradient for each aquifer investigated, including minimum, maximum and average horizontal hydraulic gradients, and ii. a description of vertical hydraulic gradients in aquifers where a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant, including minimum, maximum and average vertical hydraulic gradients. 6. Review and Evaluation | not applicable | (iv) Fine-Medium Soil Texture | Where fine-medium soil texture is to be used in determining the applicable site condition standards, provide, i. a rationale for the use of the fine-medium soil texture category, ii. a description of the results of the required grain size analysis, and iii. a description and rationale for the number of samples collected and analyzed. 6. Review and Evaluation | not applicable | (v) Soil: Field Screening | Provide a discussion of soil field screening results. 6. Review and Evaluation | not applicable | (vi) Soil Quality | Provide a discussion and analysis of the laboratory analytical results for all soil samples analyzed including, i. locations and depths of samples, ii. comparison of analytical results to applicable site conditions standards, iii. contaminants of concern, iv. contaminants related to chemical and biological transformations that have or may have occurred, v. whether the results indicate soil serves as a source of contaminant mass contributing to ground water or sediment, and vi. whether the results indicate the presence of light or dense non-aqueous phase liquids. 6. Review and Evaluation | not applicable | (vii) Ground Water Quality | Provide a discussion and analysis of the laboratory analytical results for all ground water samples analyzed including, i. locations and sample depth interval of samples, ii. documentation of any field filtering, iii. comparison of analytical results to applicable site conditions standards, iv. contaminants of concern, v. contaminants related to chemical and biological transformations that have or may have occurred, vi. whether the results indicate soil serves as a source of contaminant mass contributing to ground water or sediment, and vii. whether the results indicate the presence of light or dense non-aqueous phase liquids. 6. Review and Evaluation | not applicable | (viii) Sediment Quality | Provide a discussion and analysis of the laboratory analytical results for any sediment samples analyzed including, i. locations and depths of samples, ii. comparison of analytical results to applicable site conditions standards, iii. contaminants of concern, iv. contaminants related to chemical and biological transformations that have or may have occurred, and v. whether the results indicate the presence of light or dense non-aqueous phase liquids. 6. Review and Evaluation | not applicable | (ix) Quality Assurance and Quality Control Results | 1. Provide a description of the types of quality control samples collected and results of any other quality assurance and quality control measures taken during the field investigation, including the types of quality control samples, the media sampled, and the importance of the results with respect to ensuring the data are useful, appropriate and accurate in the determination of whether the phase two property, or any RSC property within it, meets the applicable site condition standards and any standards specified in a risk assessment. 2. Provide a description of each instance where a sample was not handled in accordance with the Analytical Protocol with respect to, i. holding time, ii. preservation method, iii. storage requirement, or iv. container type. 3. Provide a statement, with respect to subsection 47 (3) of the regulation that, i. all certificates of analysis or analytical reports received pursuant to clause 47 (2) (b) of the regulation comply with subsection 47 (3), ii. a certificate of analysis or analytical report has been received for each sample submitted for analysis, and iii. all certificates of analysis or analytical reports received have been included in full in an appendix to the phase two environmental site assessment report. 4. Provide a description of each instance where a laboratory qualified any results or made remarks in a certificate of analysis or analytical report about a sample and include a discussion of the validity of any results qualified. 5. Provide a discussion of the overall quality of the field data from the investigation with respect to the data quality objectives, to demonstrate that, i. decision-making was not affected, and ii. the overall objectives of the investigation and the assessment were met. 6. Review and Evaluation | not applicable | (x) Phase Two Conceptual Site Model | 1. Provide a narrative description and assessment of, i. areas where potentially contaminating activity has occurred, ii. areas of potential environmental concern, and iii. any subsurface structures and utilities on, in or under the phase two property that may affect contaminant distribution and transport. 2. Provide a narrative description of and, as appropriate, figures illustrating, the physical setting of the phase two property and any areas under it including, i. stratigraphy from ground surface to the deepest aquifer or aquitard investigated, ii. hydrogeological characteristics, including aquifers, aquitards and, in each hydrostratigraphic unit where one or more contaminants are present at concentrations above the applicable site condition standards, lateral and vertical hydraulic gradients, iii. approximate depth to bedrock, iv. approximate depth to water table, v. any respect in which section 35, 41 or 43.1 of the regulation applies to the property, vi. areas on, in or under the phase two property where excess soil is finally placed, and vii. approximate locations, if known, of any proposed buildings and other structures. 3. Provide, where a contaminant is present on, in or under the phase two property at a concentration greater than the applicable site condition standard, identification of, i. each area where a contaminant is present on, in or under the phase two property at a concentration greater than the applicable site condition standard, ii. the contaminants associated with each of the areas referred to in subparagraph i, iii. each medium in which a contaminant associated with an area referred to in subparagraph i is present, iv. a description and assessment of what is known about each of the areas referred to in subparagraph i, v. for each parameter group as defined in the Analytical Protocol for which a contaminant has been analysed, the distribution, in each of the areas referred to in subparagraph i, of each contaminant present in the area at a concentration greater than the applicable site condition standard, for each medium in which the contaminant is present, together with figures showing the distribution, vi. anything known about the reason for the discharge into the natural environment of the contaminants present on, in or under the phase two property at a concentration greater than the applicable site condition standard, vii. anything known about migration away from any area of potential environmental concern of the contaminants present on, in or under the phase two property at a concentration greater than the applicable site condition standard, including the identification of any preferential pathways, viii. climatic or meteorological conditions that may have influenced distribution and migration of the contaminants, such as temporal fluctuations in ground water levels, and ix. if applicable, information concerning soil vapour intrusion of the contaminants into buildings including, A. relevant construction features of a building, such as a basement or crawl space, B. building heating, ventilating and air conditioning design and operation, and C. subsurface utilities. 4. Provide, where contaminants on, in or under the phase two property are present at concentrations greater than the applicable site condition standard, two or more cross-sections showing, by parameter group as defined in the Analytical Protocol for which a contaminant has been analysed, i. the lateral and vertical distribution of each contaminant in each area where the contaminant is present at a concentration greater than the applicable site condition standard in soil, ground water and sediment, ii. approximate depth to water table in each area referred to in subparagraph i, iii. stratigraphy from ground surface to the deepest aquifer or aquitard investigated, and iv. any subsurface structures and utilities that may affect contaminant distribution and transport in each area referred to in subparagraph i. 5. Provide, for each area where a contaminant is present on, in or under the property at a concentration greater than the applicable site condition standard for the contaminant, a diagram identifying, with narrative explanatory notes, i. the release mechanisms, ii. contaminant transport pathway, iii. the human and ecological receptors located on, in or under the phase two property, iv. receptor exposure points, and v. routes of exposure. 6. If a non-standard delineation was conducted in accordance with section 7.1 of this Schedule as part of preparing the phase two environmental site assessment report, provide a narrative description of how the non-standard delineation satisfies the requirements in that section. 7. If the exemption set out in paragraph 1, 1.1 or 2 of section 49.1 of the regulation is being relied upon, provide a statement as to the reliance upon the exemption and a narrative description of the rationale for relying upon the exemption, which may be based on information gathered during the site investigation. 8. If the exemption set out in paragraph 3 of section 49.1 of the regulation is being relied upon, provide, i. a statement as to the reliance upon the exemption, ii. a narrative description of the rationale for relying upon the exemption, which may be based on information gathered during the site investigation, and iii. one or more cross-sections and one or more figures in plan view of the phase two property that demonstrate, through identification of sample locations, sample depths and contaminant concentrations, the distribution of the contaminant in question laterally and vertically and the range of concentrations of that contaminant on, in or under the phase two property. 9. If the exemption in subsection 6 (2) of this Schedule is being relied upon, provide a narrative description in accordance with subsections 43 (3) and (4) of this Schedule. 7. Conclusions | not applicable | not applicable | Provide a summary of the information about the following: i. the location and concentration of contaminants in the land or water on, in or under the phase two property, ii. environmental conditions in the land or water on, in or under the phase two property where it is necessary to undertake a risk assessment with respect to one or more contaminants of concern, and iii. whether applicable site condition standards and standards specified in a risk assessment for contaminants on, in or under the phase two property were met as of the certification date. 7. Conclusions | not applicable | (i) Signatures | Provide, i. original signatures of the qualified person who conducted or supervised the phase two environmental site assessment, and ii. a statement by the qualified person confirming the carrying out of the phase two environmental site assessment and the findings and conclusions of the report. 8. References | not applicable | not applicable | Ensure that the phase two environmental site assessment report includes a list of all documents or data cited in the report. 9. Figures and Tables | (a) Tables | (i) Monitoring Well Installation | Provide a table showing construction details and elevations for all monitoring wells installed during the field investigation. 9. Figures and Tables | (a) Tables | (ii) Water Levels | Provide a table showing all water level measurements for all monitoring events at or under the phase two property, including depth to water reported as elevations to the nearest centimetre relative to a geodetic or permanent and recoverable benchmark and reference elevations. 9. Figures and Tables | (a) Tables | (iii) LNAPLs and DNAPLs | Provide a table showing all light or dense non-aqueous phase liquid measurements at or under the phase two property, reported as elevations to the nearest centimetre relative to a geodetic or permanent and recoverable benchmark and reference elevations. 9. Figures and Tables | (a) Tables | (iv) Soil Data | Provide one or more tables that, i. show soil quality data contained in laboratory certificates of analysis of samples taken at or under the phase two property, ii. include the borehole, test hole, test pit or monitoring well identification number, sample depths, sample identification number, date of sample collection, date of analysis and laboratory certificate of analysis or analytical report reference number, and iii. include a comparison of the data to applicable site condition standards. 9. Figures and Tables | (a) Tables | (v) Ground Water Data | Provide one or more tables that, i. show any ground water quality data contained in laboratory certificates of analysis of samples taken at or under the phase two property, ii. include the test hole or monitoring well identification number, sample identification number, sampling depth intervals, date of sample collection, date of analysis and laboratory certificate of analysis or analytical report reference number, and iii. include a comparison of the data to applicable site condition standards. 9. Figures and Tables | (a) Tables | (vi) Sediment Data | Provide one or more tables that, i. summarize all sediment quality data contained in laboratory certificates of analysis of samples taken at or under the phase two property, ii. include the sample identification number, sampling depths, date of sample collection, date of analysis and laboratory certificate of analysis or analytical report reference number, and iii. include a comparison of the data to applicable site condition standards. 9. Figures and Tables | (a) Tables | (vii) Ground Water, Sediment and Soil Maximum Concentration Data | Provide a table showing, for each contaminant for which sampling and analysis has been performed, the maximum known concentration of each contaminant on, in or under the phase two property as of the certification date including, i. the location and unique identification number of each borehole, test pit, test hole or monitoring well from which the sample showing the maximum concentration was collected, and ii. the relevant soil sampling depths, sediment sampling depths, and ground water sampling depth intervals. 9. Figures and Tables | (b) Figures | (i) Areas of Natural Significance and Water Bodies | Provide a figure that illustrates the location of any, i. area of natural significance that includes the phase two property, that is adjacent to the phase two property or that is located, wholly or partly, on the phase two property or within 30 metres of the phase two property or part of the phase two property, and ii. water body located adjacent to the phase two property, wholly or partly on the phase two property, within 30 metres of the phase two property or part of the phase two property. 9. Figures and Tables | (b) Figures | (ii) Property Before Actions Taken to Reduce the Concentration of Contaminants | Provide a figure showing, in a plan view, all features relevant to the phase two environmental site assessment prior to any actions being taken to reduce the concentration of contaminants, including, i. areas where a contaminant is present at a concentration greater than the applicable site condition standards for the contaminant, and ii. the locations of buildings, storage tanks, drainage features and fill areas on or under the phase two property. 9. Figures and Tables | (b) Figures | (iii) Interpreted Contours of Ground Water Elevations | Provide a figure showing the phase two property that shows interpreted contours of the ground water elevations for each hydrostratigraphic unit where at least three monitoring wells have been installed to permit contouring and includes, i. monitoring well identification numbers, ii. water elevation at each monitoring well used for contouring, iii. labelling of the elevation contour, iv. ground water elevations contoured, which shall obey and not extend outside the dataset, and v. arrows indicating the qualified person’s interpretation of lateral ground water flow direction at the phase two property. 9. Figures and Tables | (b) Figures | (iv) Contaminants in Soil Before Actions Taken to Reduce the Concentration of Contaminants | Where one or more contaminants in soil at or under the phase two property are present at a concentration greater than the applicable site condition standard for the contaminant prior to any actions taken to reduce the concentration of contaminants, provide one or more figures in plan view of the phase two property that show the concentration of contaminants as analyzed in an accredited laboratory, in all boreholes, test holes, test pits and any other soil sampling locations. 9. Figures and Tables | (b) Figures | (v) Contaminants in Ground Water Before Actions Taken to Reduce the Concentration of Contaminants | Where one or more contaminants in ground water at or under the phase two property are greater than the applicable site condition standard prior to any actions taken to reduce the concentration of contaminants, provide one or more figures in plan view of the phase two property that show the concentration of contaminants, as analyzed in an accredited laboratory, in all monitoring wells and test holes. 9. Figures and Tables | (b) Figures | (vi) Contaminants in Sediment Before Actions Taken to Reduce the Concentration of Contaminants | Where one or more contaminants in sediment at or under the phase two property are greater than the applicable site condition standard prior to any actions taken to reduce the concentration of contaminants, provide one or more figures in plan view of the phase two property that show the concentration of contaminants, as analyzed in an accredited laboratory, in all sediment sample locations. 9. Figures and Tables | (b) Figures | (vii) Delineation | For each parameter group defined in the Analytical Protocol for which a contaminant has been analysed, provide figures showing the phase two property in a plan view and illustrating the delineation of the lateral and vertical extent of contaminants of concern in soil, ground water or sediment for each area where contaminants are present at concentrations greater than the applicable site condition standard including, i. sampling locations, ii. sample identification number, iii. sampling points, iv. sampling depths, v. sampling depth intervals, vi. concentrations of contaminants as analyzed in an accredited laboratory, and vii. the applicable site condition standard or standard specified in a risk assessment for each contaminant analyzed. 9. Figures and Tables | (b) Figures | (viii) Contaminants of Concern in Areas of Potential Environmental Concern | For each parameter group defined in the Analytical Protocol for which a contaminant has been analysed, provide cross-sections that are oriented parallel and perpendicular to the direction of ground water flow at the phase two property illustrating, i. the delineation of the lateral and vertical extent of contaminants of concern in soil, ground water or sediment for each area of potential environmental concern and showing sample locations, sample identification numbers, sampling points, sampling depths and sampling depth intervals, ii. concentration of contaminants analyzed in an accredited laboratory, iii. in highlighting, all concentrations of contaminants in excess of the applicable site condition standard or standard specified in a risk assessment, and iv. the stratigraphy from ground surface to the deepest aquifer or aquitard investigated. 10. Appendices | (a) General | (i) Sampling and Analysis Plan | Provide the sampling and analysis plan for the site investigation. 10. Appendices | (a) General | (ii) Finalized Field Logs | Provide all finalized field logs. 10. Appendices | (a) General | (iii) Certificates of Analysis or Analytical Reports from Laboratories | Provide laboratory certificates of analysis or analytical reports for all samples analyzed. 10. Appendices | (a) General | (iv) Residue Management | Provide copies of all permits, approvals and the like obtained from municipal, provincial or federal governments or agencies for handling, treating, discharging and disposing of soil, sediment and ground water. 10. Appendices | (a) General | (v) Survey of Phase Two Property | Provide a survey of the phase two property which has been prepared, signed and sealed by a surveyor or, where the phase two property consists of land that is administered by the Ministry of Natural Resources under the Public Lands Act, a description of the phase two property approved by the Surveyor General. 10. Appendices | (b) Remediation | (i) Where any Action has been Taken to Reduce the Concentration of Contaminants on, in or under a Phase Two Property | Provide a remediation appendix that includes the following sections, i. remedial actions, ii. free flowing product, iii. results of confirmation sampling and analysis, and iv. conclusions. 10. Appendices | (b) Remediation | (ii) Remedial Actions | 1. Provide a description of any soil excavation and soil treatment activities at the phase two property that includes, i. the rationale for each method used, ii. the quantities and types of compounds used to treat contaminants of concern, and iii. the location of the remedial action. 2. Provide an estimate of the quantity of soil treated on the property and removed from the property, in tonnes. 3. Provide a description of any ground water removal or ground water treatment activities at the phase two property, including, i. the rationale for each method used, ii. the quantities and types of compounds used to treat contaminants of concern, and iii. the location of the remedial action. 4. Provide an estimate, in litres, of the volume of any ground water removed from the phase two property. 5. Provide a description of any actions taken to reduce contaminant concentrations in sediment at the phase two property, including, i. the rationale for each method used, ii. the quantities and types of compounds used to treat contaminants of concern, and iii. the location of the remedial action in relation to any areas of potential environmental concern. 6. Provide an estimate of the quantity of sediment treated or removed from the property. 7. Provide copies of all permits from local, provincial and federal agencies for handling, treating, discharging and disposing of soil, ground water or sediment. 8. Provide a description of the steps taken to ensure that contaminants created or introduced to the property during remediation do not exceed the applicable site condition standard, if the remediation method involved the creation or introduction of contaminants or substances to the subsurface of the property. 9. Provide a description of the steps taken to establish baseline and background conditions relevant to the proposed remediation method to a degree adequate to detect any increases of contaminants on, in or under the phase two property following remediation, including contaminants created or introduced to the property during remediation. 10. Provide a rationale for the selection of monitoring wells and contaminants to be analyzed for the purpose of monitoring concentrations of contaminants on, in or under the phase two property, including contaminants created or introduced to the property during remediation. 10. Appendices | (b) Remediation | (iii) Free Flowing Product | Provide, i. a discussion of the types and quantities of any free flowing product observed during remediation, ii. an estimate of the volume of free flowing product, in litres, removed from ground water on, in or under the phase two property, where free flowing product is present, and iii. a description of any free flowing product recovery system or other activity undertaken to remove the free flowing product. 10. Appendices | (b) Remediation | (iv) Confirmation Sampling and Analysis | 1. Provide a description of all confirmation sampling activities conducted during and after remedial actions for the purpose of demonstrating that the phase two property meets the applicable site condition standards and any standards specified in a risk assessment. 2. Provide a description and rationale for all confirmation sampling locations, depths and contaminants analyzed. 3. Provide a description of the lateral and vertical dimensions of the excavations and the number and types of confirmation samples taken at each excavation, where part or all of the land on, in or under a phase two property has been excavated. 4. Provide one or more figures of the phase two property, identifying the locations and dimensions of any excavations on, in or under the phase two property. 5. Provide one or more cross-sections that show the vertical dimensions of any excavations on, in or under the phase two property. 6. Provide one or more figures of the phase two property, identifying the locations of any ground water removal or treatment activities, including the locations of any injection wells and extraction wells. 7. Provide one or more figures of the phase two property, identifying the locations of any sediment removal or treatment activities. 8. Provide a description of the results of quarterly sampling events, including water level measurements and ground water sampling and analysis, where in situ treatment has been undertaken on, in or under the phase two property. 9. Provide a description of the results of quarterly sampling events, including water level measurements and ground water sampling and analysis, where excavation has been undertaken on, in or under the phase two property. 10. Provide tables showing all soil, ground water and sediment quality data contained in laboratory certificates of analysis or analytical reports for confirmation samples, including, i. comparison of the data to applicable site condition standards or standards specified in a risk assessment as the case may be for each contaminant analyzed, ii. the borehole, test hole, test pit or monitoring well identification number, iii. the sample identification number, iv. soil or sediment sample depth, v. ground water sampling depth interval, vi. date of sample collection, vii. date of sample analysis, and viii. laboratory certificate of analysis or analytical report reference number. 11. For each parameter group defined in the Analytical Protocol for which a contaminant has been analysed, provide one or more figures that show the results of analyses for all confirmation samples of soil, ground water and sediment, including the delineation of the lateral and vertical extent of contaminants in soil, ground water or sediment following actions taken to reduce the concentration of contaminants, and illustrating, i. sampling locations, ii. sample identification number, iii. sampling points, iv. sampling depths, v. sampling depth intervals, vi. concentrations of contaminants as analyzed in an accredited laboratory, and vii. the applicable site condition standard or standard specified in a risk assessment for each contaminant analysed. 12. For each parameter group defined in the Analytical Protocol for which a contaminant has been analysed, provide cross-sections that are oriented parallel and perpendicular to the direction of ground water flow that show the results of analyses for all confirmation samples of soil, ground water and sediment, including the delineation of the lateral and vertical extent of contaminants in soil, ground water or sediment following actions taken to reduce the concentration of contaminants, and illustrating, i. sampling locations, ii. sample identification number, iii. sampling points, iv. sampling depths, v. sampling depth intervals, vi. concentrations of contaminants as analyzed in an accredited laboratory, vii. the applicable site condition standard or standard specified in a risk assessment for each contaminant analyzed, viii. approximate depth to water table, and ix. the stratigraphy from ground surface to the deepest aquifer or aquitard where actions were taken to reduce the concentration of contaminants. 13. Provide a table showing construction details and elevations for all monitoring wells used in demonstrating that contaminant concentrations in ground water are below the applicable site condition standards following actions taken to reduce concentration of contaminants. 14. Provide a table showing all water level measurements for all monitoring events used in demonstrating that contaminant concentrations in ground water are below the applicable site condition standards following actions taken to reduce concentration of contaminants, including depth to water reported as elevations to the nearest centimetre relative to a geodetic or permanent and recoverable benchmark and reference elevations. 10. Appendices | (c) Soil Excavated at or Brought to the Phase Two Property | (i) Soil Brought to the Phase Two Property | 1. Provide a rationale for the selection of chemical parameters analyzed by a laboratory in accordance with section 31 of this Schedule. 2. Provide a description of the soil sampling activities conducted, including, i. the number of samples analyzed, ii. the soil sampling program, including methods used to ensure that the samples are representative of any areas where a contaminant may be present at a concentration greater than the applicable soil quality standard, as determined in accordance with the Excess Soil Standards, iii. the address of the source property and any property where the soil was stored prior to being deposited on, in or under the phase two property, iv. the former and current uses of the source property, including identification of any potentially contaminating activity, v. total volume of soil brought to the phase two property, vi. the results of analyses of soil samples, including a comparison of the results to the applicable soil quality standards set out in the Excess Soil Standards, vii. a figure showing the locations on the phase two property where soil was deposited, and viii. tables, A. showing all soil quality data contained in laboratory certificates of analysis of soil, samples analyzed, and B. comparing the analytical results to the applicable soil quality standards set out in the Excess Soil Standards. 3. Provide a description of the purposes for which the soil was brought to the phase two property. 10. Appendices | (c) Soil Excavated at or Brought to the Phase Two Property | (ii) Segregation of Soil | Provide, i. a rationale for the choice of contaminants to be analyzed, ii. a description of the methods used to ensure uniform and representative sample collection, iii. the number of soil samples collected and the volume of each stockpile, and iv. a comparison of the results of analysis to the applicable site condition standards and standards specified in a risk assessment for all contaminants analyzed. 10. Appendices | (c) Soil Excavated at or Brought to the Phase Two Property | (iii) Stockpiles | Provide, i. a rationale for the choice, ii. a description of the stockpile sampling program, including methods used to ensure uniform and representative sample collection, the number of soil samples collected and the volume of each stockpile, iii. in respect of soil excavated at the phase two property, a table showing all soil quality data contained in certificates of analysis or analytical reports for stockpiled soil samples analyzed and a comparison of the analytical results to the applicable site condition standards and standards specified in a risk assessment, and iv. in respect of excess soil brought to the phase two property, a comparison of the analytical results to applicable soil quality standards set out in the Excess Soil Standards. 10. Appendices | (d) Modified Generic Risk Assessment | (i) Property Information | Provide, i. property location and ownership, ii. municipal address and property identification number, if any, iii. size and boundaries of the property, and iv. identification of the current and proposed uses of the property. 10. Appendices | (d) Modified Generic Risk Assessment | (ii) Fraction of Organic Carbon (FOC) | Whenever an assumed value for FOC (for the water table to soil surface, in the upper 0.5 m, or the aquifer) is to be modified in a modified generic risk assessment, the report shall include, i. a description of the rationale for determining sampling locations, ii. a table with the sampling results, iii. a figure showing the sampling points, iv. finalized field logs, indicating the depth of the soil samples, and v. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (iii) Distance to Water Body | Whenever an assumed value for distance to water body is to be modified in a modified generic risk assessment, the report shall include a figure showing, i. the location of the property, ii. areas where a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant, iii. the location of monitoring wells, ground water flow direction, interpreted flow pathways from each area to the nearest water body, and estimated distance from each area to the nearest water body, iv. nearest water body down gradient of each area noted in ii, and v. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (iv) Depth to Water Table | Whenever an assumed value for depth to water table is to be modified in a modified generic risk assessment, the report shall include, i. a description of, and rationale for, the method used to estimate the depth from soil surface to the highest water table, ii. a figure showing the soil surface elevation contours, monitoring well locations, and measured depths to the highest water table from soil surface, iii. a table with all the water level data used to determine the highest water table, and iv. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (v) Aquifer Horizontal Hydraulic Gradient | Whenever an assumed value for aquifer horizontal hydraulic gradient is to be modified in a modified generic risk assessment, the report shall include, i. a figure showing the location of monitoring wells, water level information, and ground water elevation contours, ii. gradient calculations, and iii. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (vi) Aquifer Horizontal Hydraulic Conductivity | Whenever an assumed value for aquifer horizontal hydraulic conductivity is to be modified in a modified generic risk assessment, the report shall include, i. a description of field test methods, and interpretation of the field data, ii. a rationale for the decision to use or not use a multiplier, and for the particular choice and use of any multiplier chosen and used in adjusting hydraulic conductivity values, iii. all field data, calculations, and hydraulic conductivity values, and iv. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (vii) Soil Type in the Vadose Zone and Capillary Fringe | Whenever an assumed value for soil type in the vadose zone and capillary fringe is to be modified in a modified generic risk assessment, the report shall include the following contents: 1. For each area where a contaminant is present on, in or under the property at a concentration greater than the applicable site condition standard for the contaminant, the following information related to soil type in the vadose zone and capillary fringe, if applicable, i. a description of grain size analysis undertaken by an accredited laboratory and the process and rationale for the selection of the soil type, ii. grain size distribution curves, iii. a figure showing all the sampling points, and iv. related finalized field logs, indicating the depth of the soil samples. 2. Soil type selected as property soil type (for each of the vadose zone and capillary fringe), and the area soil type (in each of the vadose zone and capillary fringe) for each of the areas investigated. 10. Appendices | (d) Modified Generic Risk Assessment | (viii) Soil Vapour Investigation - Depth to Soil Vapour Measurements | Whenever an assumed value for depth below soil surface to soil vapour is to be entered in a modified generic risk assessment, the report shall include the following contents: 1. A description of the rationale for the selection of the soil vapour sampling locations and depths. 2. A discussion on soil vapour preferential pathways present or anticipated on the property, and whether and how they may affect vapour intrusion into existing and any known future buildings. 3. A figure showing the locations of, i. existing and, if known, future buildings, ii. all soil vapour points, iii. areas where volatile contaminants are present at a concentration greater than the applicable site condition standards, iv. known or inferred volatile contaminant release areas, and v. ground water flow direction. 4. A minimum of one cross section for each area at which a contaminant is present at a concentration above the applicable site condition standards for the contaminant, which illustrates, i. variations in the soil surface elevation at the property, ii. soil and ground water sampling points, iii. soil vapour probe locations and depths, iv. interpreted distribution of the soil types present in the area, v. depth to water table, and vi. soil and ground water concentrations for the volatile contaminants referred to above. 5. A table summarizing the rationale for the location and depth of each soil vapour probe used in the soil vapour investigation, construction details of the probes, including materials, diameter, length of the screen interval, and depth from soil surface to the top of the probe screening interval. 10. Appendices | (d) Modified Generic Risk Assessment | (ix) Soil Vapour Investigations - Soil Vapour Concentrations | Whenever a value for soil vapour concentration is to be entered in a modified generic risk assessment, the report shall include, i. a description of the soil vapour analytical methods, data quality objectives, rationale for the selected sampling method, devices and sampling duration, ii. a description of the standard operating procedures for soil vapour probe installation and soil vapour probe development, performance testing, leak testing, purging and sampling used in the field investigation, iii. a description of the quality assurance and quality control measures implemented, iv. soil vapour field data, including leak test data, purge volumes and sample rates, v. soil vapour laboratory results presented in a tabular format by soil vapour sampling location and probe, including in the table depth to measurement (from soil surface to the top of the probe screening interval) and approved model calculated soil vapour screening level for each volatile contaminant, vi. soil vapour probe finalized field logs, including depths and installation details, and vii. certificates of analysis or analytical reports for all soil vapour samples. 10. Appendices | (d) Modified Generic Risk Assessment | (x) Number of Frozen Ground Days per Year | Whenever an assumed value for frozen days is to be modified in a modified generic risk assessment, the report shall include, i. the name and location of the meteorological station, and ii. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (xi) Aquifer Soil Dry Bulk Density | Whenever an assumed value for aquifer soil dry bulk density is to be modified in a modified generic risk assessment, the report shall include, i. a description of the test method used to determine the aquifer soil bulk density along with the data used for the determination of the test results and a site map showing the sampling points, and ii. the new value to be used in the modified generic risk assessment. 10. Appendices | (d) Modified Generic Risk Assessment | (xii) References | Include a list of all documents or data cited in the report. Table 2 Minimum Stockpile Sampling Frequency Item | Column 1 Stockpile Volume (m3) | Column 2 Minimum Number of Samples 1. | ≤ 130 | 3 2. | > 130 to 220 | 4 3. | > 220 to 320 | 5 4. | > 320 to 430 | 6 5. | > 430 to 550 | 7 6. | > 550 to 670 | 8 7. | > 670 to 800 | 9 8. | > 800 to 950 | 10 9. | > 950 to 1100 | 11 10. | > 1100 to 1250 | 12 11. | > 1250 to 1400 | 13 12. | > 1400 to 1550 | 14 13. | > 1550 to 1700 | 15 14. | > 1700 to 1850 | 16 15. | > 1850 to 2050 | 17 16. | > 2050 to 2200 | 18 17. | > 2200 to 2350 | 19 18. | > 2350 to 2500 | 20 19. | > 2500 to 2700 | 21 20. | > 2700 to 2900 | 22 21. | > 2900 to 3100 | 23 22. | > 3100 to 3300 | 24 23. | > 3300 to 3500 | 25 24. | > 3501 to 3700 | 26 25. | > 3700 to 3900 | 27 26. | > 3900 to 4100 | 28 27. | > 4100 to 4300 | 29 28. | > 4300 to 4500 | 30 29. | > 4500 to 4700 | 31 30. | > 4700 to 5000 | 32 31. | > 5000 | The amount determined by applying the formula set out in paragraph 6 of section 36 of this Schedule. TABLE 3 Minimum Confirmation Sampling Requirements for Excavation Floor Area (m2) | Floor Samples | Sidewall Samples - should not all be taken from the same wall, and should represent worst-case <25 | 2 | 2 >25-50 | 2 | 3 >50-100 | 3 | 3 >100-250 | 3 | 5 >250-500 | 4 | 6 >500-750 | 4 | 7 >750-1000 | 5 | 8 Table 4 Phase two environmental site assessment requirements for modified generic risk assessments Assumption Category | Objective | Minimum Requirements 1. Fraction of Organic Carbon (FOC) – Water Table to Soil Surface | (a) Determine the FOC in the area between the water table and the soil surface. | 1. Soil samples from at least four continuous borehole cores but not necessarily undisturbed soil samples must be collected at the phase two property for the purpose of defining FOC. 2. The samples must be taken from soil between the soil surface and the top of the water table. 3. The four sample locations must be chosen so as to provide results for natural (non-anthropogenic) FOC at the property. 4. The samples must be taken from soil of the same soil type present in an area where a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant. 5. A minimum of one composite soil sample for each sampling location is required for FOC determination. 6. Each soil sample for FOC determination shall be analyzed in triplicate. 7. The FOC for the phase two property shall be the mean of all the soil samples analyzed for FOC determination. 8. At least one soil sample shall be taken at each of the four sampling locations and analyzed for the contaminants of concern or contaminants of potential concern which are organic chemicals and for any other organic chemical detected. 2. Fraction of Organic Carbon (FOC) – in Upper 0.5 m | (a) Determine the FOC in the upper 0.5 m of soil immediately below soil surface. | 1. Soil samples shall be collected, from at least four locations at the property, each of which is in the upper 0.5 m of soil below soil surface at the time of sampling. 2. The sample locations must be chosen so as to provide results for natural (non-anthropogenic) FOC at the phase two property. 3. The samples must be taken from soil of the same soil type present in an area where a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant. 4. A minimum of one composite soil sample for each sampling location is required for FOC determination. 5. The FOC for the phase two property shall be the mean of all the soil samples analyzed for FOC determination. 6. At least one soil sample shall be taken at each of the four sampling locations and analyzed for the contaminants of concern or contaminants of potential concern which are organic chemicals and for any other organic chemical detected. 3. Minimum Distance From Areas Where Contaminants Present Above Applicable Site Condition Standards to Nearest Down Gradient Water Body | (a) Determine the minimum distance from the centre of areas on, in or under the phase two property at which a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant to the nearest water body that is down gradient of the area. | 1. Using hydrogeological expertise and all relevant information from the phase two environmental site assessment, determine the distance from the centre of each area on, in or under the phase two property at which a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant to the nearest water body that is down gradient of the area. 2. Determine the shortest of these distances. 4. Minimum Depth Below Soil Surface to the Highest Annual Water Table | (a) Determine the minimum depth below soil surface to the highest water table in areas where volatile contaminants are present at concentrations greater than the applicable site condition standards in ground water. | 1. Where at least two years of water table level monitoring done at intervals no less frequent than quarterly has been undertaken for the water table at or within 250 metres from the boundary of the phase two property, water table level monitoring shall be conducted monthly for three months in order to determine the minimum depth of the high water table below soil surface. Such monitoring shall be conducted during the three months at which the highest water table can reasonably be expected to be at its highest elevation ASL based on historical data. 2. If the historical water level information referred to in paragraph 1 is not available then either, a. water table level monitoring shall be conducted monthly for 12 months in order to determine the minimum depth of the highest water table below soil surface, or b. water table level fluctuations reasonably to be anticipated at the phase two property shall be identified and documented by the qualified person, water table level monitoring shall be conducted once and the greater of the anticipated fluctuation as identified by the qualified person or one metre shall be subtracted from the measurement taken during the water table level monitoring in order to determine the minimum depth of the highest water table below soil surface. 5. Aquifer horizontal hydraulic conductivity | (a) Determine the horizontal hydraulic conductivity for each aquifer that carries contaminants of concern to a water body. | 1. A representative horizontal hydraulic conductivity for each aquifer that carries contaminants of concern to a water body shall be determined, which shall be done as follows: i. Field testing shall be conducted within the coarsest geological material in the aquifer for the purpose of determining horizontal hydraulic conductivity for each aquifer that carries the contaminants of concern from the aquifer to a water body. ii. The hydraulic conductivity values from field testing shall be compared with published values associated with the geological material which was tested. iii. If the field testing values are not consistent with published values associated with the geological material in the aquifer which was tested, or if there are any other reasons to believe the field testing quality is subject to uncertainty, an appropriately conservative multiplier shall be applied to the field testing values. 6. Aquifer Horizontal Hydraulic Gradient | (a) Determine the average horizontal hydraulic gradient across the phase two property to the nearest down gradient water body. | 1. The average horizontal hydraulic gradient between aquifers on, in or under the phase two property and the nearest water body to which ground water at the property discharges shall be determined, which determination shall be done as follows: i. Water level measurements shall be taken from at least three monitoring wells at the property from the same hydrostratigrapic unit during at least one monitoring event. ii. The monitoring wells must not be placed in a straight line. iii. In selecting the monitoring wells from which to collect water level information and determining when to collect it the qualified person shall take into consideration fluctuations of ground water flow direction, so that water level measurements from these wells are representative of ground water flows from the aquifer to the nearest water body. 2. For all aquifers where a contaminant of concern is present at a concentration greater than the applicable site condition standard for the contaminant, the qualified person shall ensure the following information is prepared: i. Contours of the interpreted ground water surface based on the water level measurements. ii. A determination of the approximate water level elevation of the nearest water body. iii. A calculation of the horizontal hydraulic gradient between the phase two property and the nearest water body, using the minimum distance from areas where a contaminant is present at a concentration greater than the applicable site condition standard for the contaminant to the nearest water body calculated as indicated above. 3. Using the calculations referred to in subparagraph 2 iii, the qualified person shall ensure that the average horizontal hydraulic gradient between the phase two property and the nearest water body is calculated. 7. Aquifer Fraction of Organic Carbon (FOC) | (a) Determine the FOC in the aquifer that carries the contaminants of concern to a water body. | 1. Samples of geological material in the aquifer that carries contaminants of concern to a water body must be collected from at least two sampling points. 2. Each sample must be analyzed in triplicate. 3. The FOC for the aquifer is the mean of all the samples. 8. Property Soil Type – Vadose Zone | (a) Determine the predominant soil type for the areas at the phase two property where a contaminant is present in soil or in ground water a concentrations greater than the applicable site condition standard for the contaminant. | 1. In areas at the phase two property where a contaminant is present at concentrations greater than the applicable site condition standard for the contaminant, the predominant soil type in the vadose zone shall be determined as follows: i. For each area where a contaminant is present in soil only at a concentration greater than the applicable site condition standard for the contaminant, one or more boreholes must be advanced to the bottom of the area. ii. In any other case, one or more boreholes must be advanced to the top of the saturated zone. iii. The determination of the predominant soil type among all the areas shall be done through soil sampling and analysis as follows: a. an appropriate number and distribution of samples, but at least four samples, of soil from each area must be collected and analyzed in order to determine grain size distribution of the soil, b. grain size analysis shall be undertaken by an accredited laboratory, c. the predominant soil type from among all the areas must be determined based on analysis of the samples chosen in subparagraph a, and on borehole information, and d. where two or more soil types exist in approximately equal amounts, taking into account all the areas, the predominant soil type shall be the coarsest soil type from amongst those present in approximately equal amounts. 9. Property Soil Type – Capillary Fringe | (a) Determine the predominant soil type directly above the water table in the capillary fringe for the areas at the phase two property where a contaminant is present in ground water in concentrations greater than the applicable site condition standard for the contaminant. | 1. In areas at the phase two property where a contaminant is present at concentrations greater than the applicable site condition standard for the contaminant, the predominant soil type in the capillary fringe shall be determined through soil sampling and analysis as follows: i. One or more boreholes must be advanced to the top of the saturated zone. ii. The determination of the predominant soil type among all the areas shall be done as follows: a. an appropriate number and distribution of samples, but at least two samples, of soil from each area must be collected and analyzed in order to determine grain size distribution of the soil, b. samples must be taken from the stratum directly above the water table in the capillary fringe, c. grain size analysis shall be undertaken by an accredited laboratory, d. the predominant soil type from among all the areas must be determined based on the samples chosen in clause a, and on borehole information, and e. where two or more soil types exist in approximately equal amounts taking into account all the areas, the predominant soil type shall be the coarsest soil type from amongst those present in approximately equal amounts. 10. Area Soil Type - Vadose Zone | (a) Determine the coarsest soil type in the vadose zone in each area in which a volatile contaminant is present at a concentration greater than the applicable site condition standard for the contaminant. | 1. In each area where a volatile contaminant is present in soil, or in ground water, at a concentration greater than the applicable site condition standard for the contaminant, determine the soil type in the area. 2. For each area where a contaminant is present in soil only at a concentration greater than the applicable site condition standard for the contaminant, one or more boreholes must be advanced to the bottom of the area. 3. In any other case, one or more boreholes must be advanced to the top of the saturated zone. 4. The determination of the coarsest soil type for each area shall be done as follows: i. An appropriate number and distribution of samples, but at least four samples, of soil from each area must be collected and analyzed in order to determine grain size distribution of the soil. ii. Grain size analysis shall be undertaken by an accredited laboratory. iii. The coarsest soil type from among these samples for each are shall be identified. 11. Area Soil Type – Capillary Fringe | (a) Determine the coarsest soil type directly above the water table in the capillary fringe in each area of the phase two property where a volatile contaminant is present in ground water at a concentration greater than the applicable site condition standard for the contaminant. | 1. In each area where a volatile contaminant is present at a concentration greater than the applicable site condition standard for the contaminant the coarsest soil type directly above the water table must be determined. 2. One or more boreholes must be advanced to the top of the saturated zone. 3. The determination of the coarsest soil type among all the area shall be done as follows: i. An appropriate number and distribution of samples, but at least two samples, of soil from each area must be collected and analyzed in order to determine grain size distribution of the soil. ii. Grain size analysis shall be undertaken by an accredited laboratory. iii. Samples must be taken from the stratum directly above the water table in the capillary fringe. iv. The coarsest soil type from among these samples for each area where a volatile contaminant is present in ground water at a concentration greater than the applicable site condition standard for the contaminant shall be identified. 12. Soil Vapour Concentrations and Depth to Soil Vapour Measurements | (a) Determine soil vapour concentrations in each area at the phase two property in which a volatile contaminant is present in soil, and in each area of the phase two property in which a volatile contaminant is present in ground water, at a concentration greater than the applicable site condition standard for the contaminant. | 1. Soil vapour concentrations shall be determined in each area at the phase two property in which a volatile contaminant is present at a concentration greater than the applicable site condition standard for the contaminant, which determination shall be done as follows: i. The qualified person shall ensure a sampling and analysis plan for soil vapour characterization is prepared. ii. In this plan the qualified person shall determine the appropriate sampling locations for sampling soil vapour, including the appropriate depth for each location, which locations shall include the areas, a. where known or inferred releases of volatile contaminants have occurred, b. where the highest concentration of contaminants in soil and ground waters are present, and c. where the qualified person considers vapour intrusion related exposures may be of potential concern. iii. The soil vapour samples must be collected, a. from within the sampling location and at the depth that is approximately the same as the depth at which the highest concentration of the volatile contaminant in soil has been measured, and b. as close as possible to, but not more than 0.5 metres above the top of the capillary fringe in the area where the highest concentration of the volatile contaminant in ground water has been measured. iv. The soil vapour samples shall be collected and analyzed. v. The qualified person shall document the rationale for the selection of the soil vapour sampling locations and depths. vi. At least two soil vapour probes must be installed in each sampling location and depth. Multiple probes installed in a single borehole are not acceptable. vii. Samples shall be collected from the probes in each sampling location during at least two sampling events separated by at least three months. viii. Samples shall be collected from at least 1.5 metres below the soil surface. ix. Screen intervals in soil vapour probes used for the sampling shall not exceed 0.5 metres. x. The depth to soil vapour measurement is the distance from soil surface to the top of the probe screening interval for each soil vapour probe from which samples are collected. 2. The qualified person shall ensure that the soil vapour samples are collected using soil vapour probes that have been designed, constructed and operated within specifications for adequate measurement and in a manner that minimizes adsorption, desorption and leaks. 13. Number of Frozen Ground Days per Year | (a) Determine the number of days per year with a maximum temperature of less than 0 degrees Celsius. | 1. Determine the number of frozen days reported by Environment Canada, based on the Canadian Climate Normals, from the nearest meteorological station for which climate norms are reported. 14. Aquifer Soil Dry Bulk Density | (a) Determine the aquifer soil dry bulk density for each aquifer that carries the contaminants of concern to a water body. | 1. Samples of geological materials in the aquifer that carries the contaminants of concern to a water body must be collected from at least two sampling points. 2. Each sample must be analyzed by an appropriate field testing method or by a laboratory. 3. The aquifer soil dry bulk density is the mean of all analytical results.
Read the records of site condition — part XV.1 of the act on e-Laws ↗

Made under Environmental Protection Act, R.S.O. 1990, c. E.19.