drinking water systems, O. Reg. 170/03

Schedule 9

Cite as drinking water systems, O. Reg. 170/03, Schedule 9 · current to November 11, 2026 · consolidated from April 11, 2022 · read from e-Laws on November 16, 2026

The text

SCHEDULE 9 maintenance and operational checks Municipal: Small Non-Residential Non-Municipal: Seasonal Residential Small Non-Residential Application 9-1. This Schedule applies to the following drinking water systems: 1. Small municipal non-residential systems. 2. Non-municipal seasonal residential systems. 3. Small non-municipal non-residential systems. Equipment maintenance 9-2. (1) If a report that complies with section 21-5 of Schedule 21 has been prepared in respect of a drinking water system in accordance with that Schedule, the owner of the system and the operating authority for the system shall ensure that the maintenance schedule referred to in clause 21-5 (d) of Schedule 21 is complied with by a trained person. (2) If subsection (1) does not apply but a manufacturer of a drinking water system’s water treatment equipment has given instructions with respect to the checking or maintenance of the equipment, the owner of the system and the operating authority for the system shall ensure that the instructions are complied with by a trained person. (3) If subsections (1) and (2) do not apply and a drinking water system provides chlorination or chloramination, the owner of the system and the operating authority for the system shall ensure that all water treatment equipment is checked at least once every week by a trained person to confirm proper functioning. (4) If subsections (1), (2) and (3) do not apply, the owner of a drinking water system and the operating authority for the system shall ensure that all water treatment equipment is checked at least once every three months by a trained person to confirm proper functioning. (5) The owner of the drinking water system and the operating authority for the system shall ensure that a record is made of the date and time of every action taken under subsections (1) to (4), the name of the person who took the action and the results of the action. Chlorine residual 9-3. (1) The owner of a drinking water system that provides chlorination for primary disinfection and the operating authority for the system shall ensure that a water sample is taken at least once every day, in the treatment process at or near a location where the intended contact time has just been completed in accordance with the Ministry’s Procedure for Disinfection of Drinking Water in Ontario, and is tested immediately for free chlorine residual. (2) The owner of a drinking water system that provides chloramination for primary disinfection shall ensure that sampling and testing for combined chlorine residual is carried out by continuous monitoring equipment in the treatment process at or near a location where the intended contact time has just been completed in accordance with the Ministry’s Procedure for Disinfection of Drinking Water in Ontario. (3) The owner of a drinking water system that provides secondary disinfection and the operating authority for the system shall ensure that at least two distribution samples are taken each week in accordance with subsection (3.1) and are tested immediately for, (a) free chlorine residual, if the system provides chlorination and does not provide chloramination; or (b) combined chlorine residual, if the system provides chloramination. (3.1) At least one of the distribution samples referred to in subsection (3) must be taken at least 48 hours after, and during the same week as, one of the other distribution samples referred to in subsection (3). (4) Subsection (3) does not apply if, (a) the owner complies with section 2-3 or 2-4 of Schedule 2, whichever is applicable; and (b) all parts of the drinking water system and of the plumbing connected to the drinking water system that are downstream of the equipment provided in accordance with section 2-3 or 2-4 of Schedule 2 are enclosed in a building or other protective structure. Turbidity 9-4. (1) If, with respect to a drinking water system that obtains water from a raw water supply that is surface water, continuous monitoring equipment is required to comply with section 2-4 of Schedule 2, the owner of the system shall ensure that sampling and testing for turbidity is conducted by continuous monitoring equipment on each filter effluent line. (2) If subsection (1) does not apply to a drinking water system that obtains water from a raw water supply that is surface water, the owner of the system, and the operating authority for the system, shall ensure that a water sample is taken at least once every day on each filter effluent line and is tested immediately for turbidity. (2.1) Subsections (1) and (2) do not apply to a small municipal non-residential system or small non-municipal non-residential system that provides ultraviolet light disinfection equipment for primary disinfection and does not use chlorination or chloramination for primary disinfection, if, (a) section 2-6 of Schedule 2 is complied with; and (b) the ultraviolet light disinfection equipment has a feature that ensures that no water is directed to users of water treated by the equipment in the event that the equipment malfunctions, loses power or ceases to provide the appropriate level of disinfection. (3) Subsections (1) and (2) do not apply until the equipment required to ensure compliance with Schedule 2 commences operation. Testing by trained persons or water quality analysts 9-5. (1) The owner of a drinking water system and the operating authority for the system shall ensure that every test required by this Schedule is conducted by a trained person or a water quality analyst. (1.1) Despite subsection (1), a test required by this Schedule may be conducted by a person who is not a trained person or water quality analyst if the person, (a) has been trained by a certified operator to conduct the test; (b) works under the supervision of a certified operator; and (c) immediately advises a certified operator of all test results. (2) Subsection (1) does not apply to tests conducted by continuous monitoring equipment. Exceptions 9-6. (1) Sections 9-2 to 9-4 do not apply to a small municipal non-residential system or a small non-municipal non-residential system on days on which all designated facilities and all public facilities served by the system are not open. (2) Sections 9-2 to 9-4 do not apply to a non-municipal seasonal residential system during a period of 60 or more consecutive days when the system, (a) is not supplying water to any designated facilities or public facilities that are open; (b) is not supplying water to any major residential development; and (c) is not supplying water to any trailer park or campground that has more than five service connections. 9-7. Revoked: O. Reg. 253/05, s. 14. Transition: trained persons 9-8. If the owner of a drinking water system is not required to comply with sections 2-2 to 2-6 of Schedule 2 until after June 1, 2003, a reference in this Schedule to a trained person shall be deemed, with respect to that system, to be a reference to any person until the equipment required to ensure compliance with Schedule 2 commences operation.
Read the drinking water systems on e-Laws ↗

Made under Safe Drinking Water Act, 2002, S.O. 2002, c. 32.