Fuel Industry Certificates, O. Reg. 215/01

Section 52.2

GUT-1 certificate

Cite as Fuel Industry Certificates, O. Reg. 215/01, s. 52.2 · current to November 11, 2026 · consolidated from January 1, 2022 · read from e-Laws on November 16, 2026

The text

(1) A person who is the holder of a GUT-1 certificate may inspect, test, adjust, purge or activate a natural gas appliance and the equipment and accessories essential to its operation but only during those hours that the certificate holder is working as an employee of a natural gas distributor. O. Reg. 253/08, s. 32. (2) A person referred to in subsection (1) may also do the following: 1. Inspect, test, repair, adjust, alter, purge, activate or reactivate any piping or tubing, or component in a piping or tubing system, to an appliance downstream of the natural gas meter. 2. Inspect, test, repair, adjust, activate or reactivate any vent, vent connector, draft control device or other component in an appliance venting system. 3. Disconnect and reconnect water piping in order to inspect, test, adjust, activate or reactivate approved appliances or controls, control systems, components and accessories that are essential to the operation of the appliance, but the person shall not perform any additional plumbing unless the person is the holder of a certificate of qualification or a provisional certificate of qualification in the trade of plumber or steamfitter, that is not suspended and that is issued under the Building Opportunities in the Skilled Trades Act, 2021. 4. Inspect, test, repair, adjust, activate or reactivate a mechanical or electrical component or accessory that forms part of an appliance or that is essential to the operation of the appliance. 5. Perform such tasks as are necessary to inspect, test, repair, replace and adjust controls and components that form part of an appliance. 6. Disconnect and reconnect electrical wiring in order to inspect, test, activate or reactivate an approved appliance and carry out the replacement of electrical wiring necessary to complete the reconnection of controls, control systems, components and accessories that are essential to the operation of the appliance; but the person shall not perform any additional wiring unless the person is the holder of a certificate of qualification or a provisional certificate of qualification in the trade of electrician — construction and maintenance or electrician — domestic and rural, that is not suspended and that is issued under the Building Opportunities in the Skilled Trades Act, 2021. 7. Inspect a flue where an oil appliance is vented through the same flue as a gas appliance. O. Reg. 253/08, s. 32; O. Reg. 441/12, s. 6; O. Reg. 887/21, s. 1. (3) A natural gas distributor who employs a holder of a GUT-1 certificate shall immediately advise the director when the certificate holder ceases to be employed by the distributor. O. Reg. 253/08, s. 32.
Read the Fuel Industry Certificates on e-Laws ↗

Made under Technical Standards and Safety Act, 2000, S.O. 2000, c. 16.