(1) A firefighter who may be exposed to an oxygen deficient atmosphere or to harmful concentrations of air contaminants when engaged in structural fire-fighting or rescue shall wear positive-pressure self-contained respiratory protective equipment that meets or exceeds NFPA 1981, “Standard on Open-Circuit Self-Contained Breathing Apparatus for Fire Fighters”, 1992 edition, together with a protective hood that meets or exceeds the requirements in Chapter 6-1 of NFPA 1971, “Standard for Protective Clothing for Structural Fire Fighting”, 1991 edition.
(2) An employer shall ensure that a firefighter who is wearing self-contained respiratory protective equipment when engaged in structural fire-fighting or rescue is accompanied by another firefighter similarly equipped and having the same air capacity.
(3) An employer shall ensure that the compressed breathing air used in self-contained respiratory protective equipment required under subsection (1) meets or exceeds CSA standard CAN3-Z180.1-M85, “Compressed Breathing Air and Systems”.
(4) An employer shall ensure that self-contained respiratory protective equipment used by a firefighter when engaged in structural fire-fighting or rescue is equipped with a personal distress alarm device that meets or exceeds NFPA 1982, “Standard on Personal Alert Safety Systems (PASS) for Fire Fighters”, 1993 edition.
(5) An employer shall ensure that CSA standard Z94.4-11(R2016), Selection, Use, and Care of Respirators, is followed concerning
(a) the training of users of self-contained respiratory protective equipment, and
(b) the use, maintenance and testing of respiratory protective equipment.