General, N.B. Reg. 91-191

Section 371

Working distance from electrical utility line or equipment

Cite as General, N.B. Reg. 91-191, s. 371 · current to June 30, 2026 · read from New Brunswick Acts and Regulations on November 16, 2026

The text

(1) An employee who works closer to an energized electrical utility line or utility line equipment than the distances specified in subsection 289(1) shall not approach, or allow any object to approach, any energized electrical utility line or utility line equipment closer than the distances specified in the following table: DISTANCE OF EMPLOYEE,UNINSULATED OBJECT OR INSULATEDOBJECT FROM ENERGIZED ELECTRICALUTILITY LINE OR UTILITY LINEEQUIPMENT VoltagePhase to Phase | Employee orUninsulatedObject | InsulatedObject Up to 750V | 600 mm | 150 mm 750V - 15kV | 900 mm | 300 mm 16kV - 25kV | 1.2 m | 450 mm 26kV - 69kV | 1.5 m | 900 mm 70kV - 138kV | 1.8 m | 1.2 m 139kV - 230kV | 2.1 m | 1.5 m 231kV - 345kV | 3.7 m | 3.0 m (2) An employee who works closer to an energized electrical utility line or utility line equipment than the distances specified in subsection 289(1) (a) shall not climb or cut a tree where any portion of the tree is closer to an energized electrical utility line or utility line equipment than the distances specified in the following table, and (b) shall ensure that no portion of a tree that is being cut, trimmed or maintained approaches any energized electrical utility line or utility line equipment closer than the distances specified in the following table: DISTANCE OF PORTION OF TREE FROM ENERGIZED ELECTRICAL UTILITY LINEOR UTILITY LINE EQUIPMENT VoltagePhase to Phase | Where Employeeis Using anUninsulatedObject | Where Employee isUsing an InsulatedObject without anInsulated AerialDevice | Where Employee isUsing an InsulatedObject with anInsulated AerialDevice Up to 750v | 300 mm | Up to butnot touching | Up to butnot touching 750v - 15kV | 600 mm | 300 mm | Up to butnot touching 16kV - 25kV | 750 mm | 450 mm | Up to butnot touching 26kV - 69kV | 1.5 m | 1.0 m | 750 mm 70kV - 138kV | 1.8 m | 1.2 m | 900 mm 139kV - 230kV | 2.1 m | 1.8 m | 1.5 m 231kV - 345kV | 3.7 m | 3.4 m | 3.0 m (3) An employer shall ensure that an employee who is permitted to work closer to an energized electrical utility line or utility line equipment than the distances specified in subsection 289(1) does not work closer to the electrical utility line or utility line equipment than the distances specified in subsections (1) and (2). (4) Where an employee referred to in subsection (1) or (2) is about to commence work that may bring any person or object closer to an energized electrical utility line or utility line equipment than the distances specified in subsection (1) or (2), an employer shall contact the authority owning or operating the electrical utility line or utility line equipment and shall ensure that the electrical utility line or utility line equipment (a) is de-energized, or (b) is adequately insulated or guarded before permitting the employee to commence the work.
Read the General on the Province's website ↗

Made under Occupational Health and Safety Act, c. O-0.2.