General, N.B. Reg. 91-191

Section 262.092

SCBA

Cite as General, N.B. Reg. 91-191, s. 262.092 · current to June 30, 2026 · read from New Brunswick Acts and Regulations on November 16, 2026

The text

If a confined space in which entry is required contains an IDLH atmosphere, an employer shall ensure that a pressure-demand SCBA or a multifunctional SCBA/airline respirator with auxiliary self-contained air supply has a minimum rated service time of 15 minutes, or additional capacity if required by the code of practice.
Read the General on the Province's website ↗

Made under Occupational Health and Safety Act, c. O-0.2.