Plumbing Licensing and Inspection, N.B. Reg. 84-187

Section 3

Cite as Plumbing Licensing and Inspection, N.B. Reg. 84-187, s. 3 · current to August 1, 2026 · read from New Brunswick Acts and Regulations on November 16, 2026

The text

(1) The Code is adopted as the standards regulating and controlling work done to plumbing systems. (1.1) Table 1.3.1.2. in Division B of the Code shall be read with the following standards added to it in alphanumeric order: (a) CSA Group standard CAN/CSA B64.1.4-11: Vacuum breaker, air space type (ASVB); (b) CSA Group standard CAN/CSA B64.2.1.1-11: Hose connection dual check vacuum breakers (HCDVB); (c) CSA Group standard CAN/CSA B64.3.1-11: Dual check valve backflow preventers with atmospheric port for carbonators (DCAPC). (1.2) Sentence 2.1.2.1.(1) of Division B of the Code shall be read as: 2.1.2.1.(1) Every sanitary drainage system shall be connected to a public sanitary sewer, a public combined sewer or a private sewage disposal system. (1.3) Sentence 2.1.2.2.(1) of Division B of the Code shall be read as: 2.1.2.2.(1) Every storm drainage system shall be connected to a public storm sewer, a public combined sewer or a designated storm water disposal location. (1.4) Sentence 2.1.2.3.(1) of Division B of the Code shall be read as: 2.1.2.3.(1) Every water distribution system shall be connected to a public water main or a potable private water supply system. (1.5) Sentence 2.2.10.10.(1) of Division B of the Code shall be read with the following standards added to it in alphanumeric order: (a) CSA Group standard CAN/CSA B64.1.4: Vacuum breaker, air space type (ASVB); (b) CSA Group standard CAN/CSA B64.2.1.1: Hose connection dual check vacuum breakers (HCDVB); (c) CSA Group standard CAN/CSA B64.3.1: Dual check valve backflow preventers with atmospheric port for carbonators (DCAPC). (2) Repealed: 92-4 (3) Repealed: 2008-76 (4) Repealed: 2008-76 (5) In addition to the requirements in Article 2.6.1.7 of Division B of the Code, (a) to prevent siphonage of storage-type service water heaters, a storage-type service water heater shall be installed with an anti-siphonage device consisting of (i) for other than bottom fed storage-type service water heaters, a cold water dip tube with a hole in the top or a vacuum relief valve installed in the cold water supply line above the top of the tank, and (ii) for bottom fed storage-type service water heaters, a vacuum relief valve installed in the cold water supply line above the top of the tank, and (b) where a storage-type water service water heater is located in a building where gravity drainage is possible at tank level, the water heater shall be installed with a corrosion resistant watertight pan under the water heater. (5.1) Sentence 2.5.4.5(1) of Division B of the Code shall be read as adding “relief vent,” after “additional circuit vent,”. (5.2) Sentence 2.6.2.6(1) of Division B of the Code shall be read with the following added in numerical order: 2.6.2.6.(2) In addition to the backflow preventer required by this Subsection for buildings or facilities where a potentially moderate health hazard may be caused by backflow, the potable water system shall be provided with premise isolation by the installation of a double check valve assembly backflow preventer. 2.6.2.6.(3) In addition to the backflow preventer required by this Subsection for buildings or facilities where a potentially minor health hazard may be caused by backflow, the potable water system shall be provided with premise isolation by the installation of a dual check valve backflow preventer in any of the following circumstances: (a) residential premises with access to an auxiliary water supply (not directly connected); (b) residential premises serving fewer than four dwelling units with a single water supply; or (c) buildings with a minor hazard classification. 2.6.2.6.(4) Single family residential premises shall not require the installation of a dual check valve backflow preventer except as provided in Clause 2.6.2.6.(3)(a). (5.3) Repealed: 2014-82 (6) Repealed: 2008-76
Read the Plumbing Licensing and Inspection on the Province's website ↗

Made under Plumbing Installation and Inspection Act, 2014, c.126.