General, N.B. Reg. 83-190
Section 42
Cite as General, N.B. Reg. 83-190, s. 42 · current to May 15, 2018 · read from New Brunswick Acts and Regulations on November 16, 2026
The text
(1) Where primary forest products are to be scaled in stacked cubic metres, a scaler shall measure and record
(a) the height of the pile,
(b) the length of the pile, and
(c) the width of the pile.
(2) A scaler shall determine the average length and height of a pile by making measurements on both the front and back of the pile or load, except in the case of primary forest products in transit where there is no clear space between the piles.
(3) A scaler shall measure the height of a pile by placing the hook of the scale stick under the bottom of a bolt in the lowest rank or tier of the pile and reading the perpendicular height to the top of a bolt in the top rank or tier, except in the case of primary forest products in transit.
(4) Where there is no clear space between piles, the scaler shall take measurements on both sides of the load, and shall estimate the deviation in interior heights to determine the average height of each pile.
(5) A scaler shall measure the height at regular intervals along the face of a pile and shall make the initial measurement at a point half the distance of the chosen interval from one end of the pile.
(6) A scaler shall measure and record the height of a pile in 0.02-m units.
(7) A scaler shall calculate and record the average height to the nearest 0.02-m unit.
(8) The length of a pile is the distance between the exterior edges of those bolts on each end of the pile, except in the case of primary forest products in transit.
(9) Where there is no clear space between piles, the scaler shall take measurements on exterior edges of a pile estimating the deviation in interior length to determine the average length of each pile.
(10) A scaler shall measure and record the length of a pile in 0.02-m units.
(11) A scaler shall calculate and record the average length to the nearest 0.02-m unit.
(12) Where a pile is on a slope, a scaler shall measure length parallel to the bottom of the pile and height perpendicular to the bottom of the pile.
(13) A scaler shall measure and record the width of the pile in 0.02-m units.
(14) A scaler shall calculate and record the average width to the nearest 0.02-m unit.
(15) A scaler shall measure bolt or half-bolt diameters inside the bark along a plane perpendicular to the longitudinal axis of the bolt.
(16) A scaler shall calculate and record the average bolt or half-bolt diameter to the nearest 2-cm unit.
(17) Where the diameter of a scaled piece coincides with the boundary between classes, that piece shall be measured and recorded to the lower class.
(18) Where a scaler has determined the length, width and height of a pile of primary forest products the scaler shall calculate the gross volume in stacked cubic metres by using the following formula:
GPV | = | L × H × W
where GPV | = | gross pile volume expressed with a precision of 0.01m3(st)
L | = | length of pile in metres
H | = | height of pile in metres
W | = | width of pile in metres
Read the General on the Province's website ↗
Made under Scalers Act, 2011, c.219.