General, N.B. Reg. 83-190

Section 13

Cite as General, N.B. Reg. 83-190, s. 13 · current to May 15, 2018 · read from New Brunswick Acts and Regulations on November 16, 2026

The text

(1) Where primary forest products are to be scaled in stacked cubic metres, a scaler shall measure and record (a) the height of the pile, (b) the length of the pile, and (c) the width of the pile. (2) A scaler shall determine the average length and height of a pile by making measurements on both the back and the front. (3) A scaler shall measure the height of a pile by placing the hook of a scale stick under the bottom of a bolt in the lowest rank or tier of the pile and reading the perpendicular height to the top of a bolt in the top rank or tier. (4) A scaler shall measure the height at regular intervals along the face of the pile and shall make the initial measurement at a point half the distance of the chosen interval from one end of the pile. (5) A scaler shall measure and record the height of a pile in 0.02-m units. (6) A scaler shall calculate and record the average height to the nearest 0.02-m unit. (7) The length of a pile is the distance between the exterior edges of the bolts on each end of the pile. (8) A scaler shall measure and record the length of a pile in 0.02-m units. (9) A scaler shall calculate and record the average length to the nearest 0.02-m unit. (10) Where a pile is on a slope, a scaler shall measure lengths parallel to the bottom of the pile and height perpendicular to the bottom of the pile. (11) A scaler shall measure and record the width of the pile in 0.02-m units. (12) A scaler shall calculate and record the average width to the nearest 0.02-m unit. (13) A scaler shall measure bolt or half-bolt diameters inside the bark along a plane perpendicular to the longitudinal axis of the bolt. (14) A scaler shall calculate and record the average bolt or half-bolt diameter to the nearest 2-cm unit. (15) Where the diameter of a scaled piece coincides with the boundary between classes, that piece shall be measured and recorded to the lower class. (16) Where a scaler has determined the length, width and height of a pile of primary forest products the scaler shall calculate the gross volume in stacked cubic metres by using the following formula: GPV | = | L × H × W where GPV | gross pile volume expressed with a precision of 0.01 m3 (st) L | = | length of pile in metres H | = | height of pile in metres W | = | width of pile in metres
Read the General on the Province's website ↗

Made under Scalers Act, 2011, c.219.