Barrier-Free Design Building Code, N.B. Reg. 2021-3

Schedule B

Cite as Barrier-Free Design Building Code, N.B. Reg. 2021-3, Schedule B · current to May 1, 2025 · read from New Brunswick Acts and Regulations on November 16, 2026

The text

Explanatory Material for Schedule A This Schedule is included for explanatory purposes only and does not form part of the requirements referred to in Schedule A. The headings in this Schedule refer to the corresponding provisions in Schedule A. References to this Schedule in Schedule A refer to the corresponding provisions in this Schedule (e.g. “see Note B-3.8.3.9. of Schedule B”). References to Notes which are contained in parentheses in Schedule A refer to the corresponding provisions of the Code (e.g. “see Note A-3.8.3.8. of the Code”). B-3.8.1. | Scope Barrier-free requirements, with few exceptions, apply to all buildings. This Regulation, for example, continues to exempt a few occupancies such as houses and small residential buildings, not more than four units. B-3.8.2.1.(1)(f) | Emergency Facilities Exempt The exemption is intended to include sleeping quarters and associated kitchen and washroom facilities, but does not extend to assembly occupancies, administration or call-centre type operations within fire, rescue or emergency response facilities. B-3.8.2.1.(6) | Residential Suites Required to be Barrier-Free Where there are more than four residential suites in a building, one suite for every 20 suites, or part thereof, must conform to the requirements of Article 3.8.3.24. Where there are four residential suites or less in a building, there is no requirement to have one suite conform to Article 3.8.3.24. B-3.8.2.3. | Areas Requiring a Barrier-Free Path of Travel In a previous version of the regulation respecting barrier-free design, the Article 3.8.1.3. included an extensive list where the path was required, however it was not all inclusive, and lead to inconsistent application of the requirement. The intent of this Regulation is now emphasized to require the barrier-free path of travel everywhere, with a few exceptions which are listed. For general guidance, readers may refer to the Code but are cautioned that this Regulation may be broader in application and, if there is conflict, this Regulation prevails. B-3.8.3.1.(1) | Design Standards Where the CSA Group standard CSA B651-18, Accessible design for the built environment, is utilized and additional items are installed that are not specifically required by the Code, those items are required to be installed in accordance with the appropriate provisions of the CSA Group standard CSA B651-18. For example, medicine cabinets are not required to be provided, but if they are installed, they shall conform to the requirements of the standard. B-3.8.3.4. | Curb Ramps Curb ramps, commonly referred to as curb cuts, are required where there are curbs in the path of travel, typically from a passenger loading zone or designated parking area to a building. Curb ramps should have a surface that is slip-resistant and colour and texture contrasted with the adjacent surfaces. B-3.8.3.14. and B-3.8.3.15. | Water Closets and Urinals Articles 3.8.3.14. and 3.8.3.15. establish the height of a water closet and rim of a urinal based on average adult user’s heights. This allows for various circumstances depending on the age or infirmity of the intended occupants. However, there are circumstances where facilities are designed specifically for the use of small children or persons with particular infirmities. These include day cares, elementary schools, group homes, homes for special care, residential care facilities, etc. Designers and code authorities should exhibit good judgement and be reasonable in allowing some variance depending on the needs of the intended users. The height of a water closet primarily intended to serve young children might be reduced to a minimum of 380 mm and, conversely, one intended to serve adult persons with physical disabilities to a height of not more than 460 mm. For a urinal primarily intended to serve small children, a minimum rim height of not more than 330 mm may be reasonable.
Read the Barrier-Free Design Building Code on the Province's website ↗

Made under Building Code Administration Act, 2020, c.8.