Dairy Plant and Transportation of Milk, N.B. Reg. 2009-139

Section 32

Temperature recording

Cite as Dairy Plant and Transportation of Milk, N.B. Reg. 2009-139, s. 32 · current to November 20, 2009 · read from New Brunswick Acts and Regulations on November 16, 2026

The text

(1) No recording chart shall be used for a period that interferes with the clarity of the record or that permits overlapping of graphs. (2) The person in charge of the recording thermometer shall sign every chart and shall ensure that the following information is recorded on every chart: (a) the date of each operation of the pasteurizer or holder; (b) the number of the pasteurizer or holder, if more than one is in use, to which the recording thermometer was attached; (c) a recording of the indicating thermometer at some time corresponding with a marked point in the holding period; and (d) the product processed in relation to each graph on the chart. (3) If more than one recording thermometer is in use, the chart shall be numbered in such a manner as to indicate the recording thermometer that was used for the chart. (4) A chart shall be kept for a period of 30 days after the date of the chart.
Read the Dairy Plant and Transportation of Milk on the Province's website ↗

Made under Public Health Act, c. P-22.4.