An operator must ensure that all of the following requirements are met:
(a) an industrial camp has the minimum number of fixtures required under Schedule 2;
(b) a building containing rooms used for sleeping, eating or other living purposes must not have toilets other than water flush toilets;
(c) water flush toilets must be connected to a public sewerage system or to a properly designed and constructed septic tank and ground absorption system;
(d) toilets must be located no more than 30 m from any bedroom;
(e) sanitary facility floors must be constructed of concrete, wood or other suitable material and finished with a smooth, watertight surface;
(f) sanitary facilities must be ventilated to the outside air,
(g) sanitary facilities must be maintained in a sanitary condition;
(h) toilets other than water flush toilets must be constructed and maintained such that
(i) pests and small domestic animals cannot access waste materials,
(ii) surface or ground water cannot enter the pit or vault,
(iii) waste material cannot contaminate a water supply, and
(iv) self-closing seat covers are in operation at all times;
(i) a sanitary privy, chemical closet or frost-proof closet must not be installed within
(i) any building used for human occupancy, or
(ii) 3 m of any dwelling.