Hazardous Waste Regulation, B.C. Reg. 63/88

Schedule 2

Schedule 2

Cite as Hazardous Waste Regulation, B.C. Reg. 63/88, Schedule 2 · last amended July 1, 2026 · read from BC Laws on November 17, 2026

The text

Schedule 2 [en. B.C. Reg. 132/92, s. 35; am. B.C. Reg. 319/2004, s. 44.] Emission Standards for Thermal Treatment Facilities Parameters Maximum Concentration(1) (mg/m3 unless otherwise indicated) Averaging Period(2) Monitoring Method(3) Carbon monoxide 55 4-hr RA C Hydrogen chloride 50 8-hr RA C Hydrogen fluoride 4 A A Nitrogen oxides (as NO2) 380 A A Opacity 5% 1-hr RA C Particulate matter 20 A A Sulphur dioxide 180 A A Total hydrocarbon (as methane) 32 A A Trace metals(4): Class 1 (lead, antimony, copper, manganese, vanadium, zinc) Class II (arsenic, chromium, cobalt, nickel, selenium, tellurium) Class III (thallium, cadmium, mercury) 3.6 0.7 0.15 A A A A A A NOTES: (1) Concentrations are corrected to 11% oxygen and standard conditions of 20C, 760 mm of mercury and dry basis. (2) Averaging period codes: RA means rolling average which is the moving time period over which the continuous monitoring data is averaged. A means as approved by a director. (3) Monitoring method codes: C means continuous. A means as approved by a director. (4) The concentrations prescribed apply to each individual metal.
Read the Hazardous Waste Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.