Cleaner Gasoline Regulation, B.C. Reg. 498/95

Section 9

Analytical methods

Cite as Cleaner Gasoline Regulation, B.C. Reg. 498/95, s. 9 · last amended March 6, 2024 · read from BC Laws on November 17, 2026

The text

(1) To determine parameter values for the purposes of this regulation, (a) the analytical methods referred to in the Canadian General Standards Board Standard CAN/CGSB-3.5-2021 Automotive gasoline must be used, (b) if the gasoline contains an amount of ethanol that is 15% or less by volume of the amount of gasoline, the analytical methods referred to in the Canadian General Standards Board Standard CAN/CGSB-3.511-2021 Oxygenated automotive gasoline containing ethanol (E1-E10 and E11-E15) must be used in addition to the analytical methods set out in paragraph (a), and (c) if the gasoline contains an amount of ethanol that is 20 to 25% or 50 to 85% by volume of the amount of gasoline, the analytical methods referred to in the Canadian General Standards Board Standard CAN/CGSB-3.512-2023 Automotive ethanol fuel (E50-E85 and E20-E25) must be used in addition to the analytical methods set out in paragraph (a). (2) Despite subsection (1) a primary distributor may use an analytical method other than one referred to in subsection (1) to determine parameter values for the purposes of this regulation provided (a) the equivalency of the alternative analytical method to an analytical method referred to in subsection (1) is established by applying the American Society for Testing and Measurements method ASTM D4855-91, Standard Practice for Comparing Test Methods, or the American Society for Testing and Measurements method ASTM D3764-92, Standard Practice for Validation of Process Steam Analyzers, and (b) 60 days before using the alternative analytical method, the primary distributor sends to a director by registered mail notice that the alternative analytical method will be used and reasons why the alternative method is equivalent to an analytical method referred to in subsection (1). (3) Despite subsection (2), if the director notifies the primary distributor that an alternative analytical method referred to in subsection (2) may not be used, the primary distributor must (a) not use the alternative analytical method, or (b) if use of the alternative analytical method was commenced before notice from the director was received by the primary distributor, cease to use the alternative analytical method.
Read the Cleaner Gasoline Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.