Pulp Mill and Pulp and Paper Mill Liquid Effluent Control Regulation, B.C. Reg. 470/90
Section 3
Sampling methods for compliance determination
Cite as Pulp Mill and Pulp and Paper Mill Liquid Effluent Control Regulation, B.C. Reg. 470/90, s. 3 · last amended April 1, 2018 · read from BC Laws on November 17, 2026
The text
(1) The compliance sampling method used to determine the effluent flow rate and temperature shall be as specified in writing by a director.
(2) The compliance sampling method used to provide an effluent sample for determination of the 96 h LC50 toxicity shall consist of a grab sample.
(3) The compliance sampling method used to provide effluent samples for determination of the 5 day biochemical oxygen demand (BOD5), the total suspended solids (TSS) and the AOX during phase I shall consist of collecting an effluent sample during a period of 24 hours by taking
(a) a continuous sample of the effluent being discharged from each effluent outfall,
(b) a composite of equal samples from each effluent outfall at least every 15 minutes, or
(c) a composite of samples from each effluent outfall at least every 15 minutes in an amount proportionate to the amount of the effluent.
(4) The compliance sampling method used to provide effluent samples for determination of BOD5, TSS and AOX during phase II shall be as specified in writing by the director.
Read the Pulp Mill and Pulp and Paper Mill Liquid Effluent Control Regulation on BC Laws ↗
Made under Environmental Management Act, SBC 2003, c. 53.