Groundwater Protection Regulation, B.C. Reg. 39/2016

Section 1

Definitions and interpretation

Cite as Groundwater Protection Regulation, B.C. Reg. 39/2016, s. 1 · last amended December 1, 2022 · read from BC Laws on November 17, 2026

The text

(1) In this regulation: “Act” means the Water Sustainability Act; “annular space” means (a) an open space between the outside of the casing of a well and the surrounding geological formation, or (b) an open space between 2 or more casings in the same well; “backfill materials” means (a) uncontaminated natural geological materials, (b) uncontaminated drill cuttings, or (c) uncontaminated non-toxic synthetic materials; “borehole” means a drilled geotechnical well, other than a test pit, that is intended to remain in service for a period of not more than 30 days after construction; “casing” means the piping or tubing installed in a well to support the sides of the well and includes production casing and surface casing; “casing stick-up”, in relation to a well, means the length of the production casing in the well that is above (a) the surface of the ground adjacent to the well, or (b) the floor of the well sump, pump house or well pit; “closed-loop geoexchange well” means a well, other than an open-loop geoexchange well, used or intended to be used for the purpose of heat exchange in a closed-loop geoexchange system in which there is no transfer of water between an aquifer and the well; “closure plug” means the sealant placed in the uppermost portion of a well that is being decommissioned; “develop”, in relation to a well, means remove from an aquifer the fine sediment and other organic or inorganic material that immediately surrounds the well screen, the drill hole or the intake area at the bottom of the well; “dewatering well” means a well used or intended to be used for the purpose of diverting or conveying groundwater by pumping in order to (a) facilitate an excavation, (b) stabilize an area of land, a building or any other improvement, or (c) reduce water pressure in a geological formation; “drainage well” means a well used or intended to be used for the purpose of diverting or conveying groundwater by the force of gravity and without pumping in order to (a) facilitate an excavation, (b) stabilize an area of land, a building or any other improvement, or (c) reduce water pressure in a geological formation; “drive shoe” means a commercially-manufactured, forged or tempered steel sleeve with a cutting edge attached to the bottom of a drive pipe or casing to act as a cutting edge or protector for the lower edge of the drive pipe or casing during drilling; “excavated well” means a well, commonly known as a dug well, excavated by (a) digging in unconsolidated materials using manual or mechanical methods, or (b) blasting in consolidated materials; “flood debris” means material, natural or otherwise, that is relocated by the movement of flood waters; “foreign matter” means a thing, matter or substance described in section 59 (1) (a) to (g) [prohibition on introducing foreign matter into well] of the Act and includes the substances prescribed under section 2 of this regulation; “former regulation” means the Ground Water Protection Regulation, B.C. Reg. 299/2004; “injection well” means a well used or intended to be used for the purpose of conveying water into a geological formation with the aid of a well pump; “liner” means piping or tubing installed in a well to protect the well pump or other works in the well from damage; “modify” means make a change, other than an alteration, to a well or wellhead; “open-loop geoexchange well” means a water supply well that is used or intended to be used for the purpose of heat exchange in an open-loop geoexchange system in which there is a transfer of water between an aquifer and the well; “permanent” means, (a) in relation to a well, a well that is intended to be in service for a period of more than 90 days after construction, and (b) in relation to a well pump, a well pump that is intended to remain installed in a well for a period of more than 90 days after installation; “pitless adapter” means a mechanical device attached to a casing for the underground conveyance of water to or from a well; “pumping test” means a flow test of a well in which the well is pumped and the quantity of water pumped, pumping water levels and recovery water levels are measured (a) to provide an estimate of the capacity of the well to produce groundwater, and (b) to assess aquifer characteristics; “recharge well” means a well used or intended to be used for the purpose of conveying water into a geological formation without the aid of a well pump and includes soakaway pits that are unfilled and cased; “register” means a register of registered persons maintained by the comptroller, as described in section 7 [registers of well drillers and well pump installers], in respect of (a) registered well drillers, or (b) registered well pump installers; “registration number” means, (a) in relation to a well driller, the registration number recorded for the well driller by the comptroller on the register of well drillers, and (b) in relation to a well pump installer, the registration number recorded for the well pump installer by the comptroller on the register of well pump installers; “rehabilitate”, in relation to a well, means use chemical, mechanical or physical methods to improve or restore the capacity of the well to produce groundwater; “remediation well” means a well that is used or intended to be used for the purpose of groundwater remediation, including the removal or treatment of contaminants that have entered an aquifer; “screen assembly”, in relation to a well, means (a) a screen in the well, (b) a closed bottom, and (c) any other related components, including a riser pipe, packer, screen blank or tail pipe, that are required for (i) the method or type of installation of the screen, or (ii) the nature of the geological formation; “sealant” means a sealing material or mixture of sealing materials that is (a) less permeable than the surrounding geological formation to be sealed, (b) appropriate for the particular soil and water conditions, and (c) non-toxic and does not have an adverse impact on the quality of the groundwater in an aquifer or a well; “shut-in pressure”, in relation to a flowing artesian well, means (a) the water pressure after the artesian flow has been stopped, or (b) the height of the water above the top of the production casing or above the surface of the ground after the artesian flow has been stopped; “sounding tube” means a tube that enables the groundwater level in a well to be measured; “static water level”, in relation to a well, means the distance from the top of the production casing or the surface of the ground to the groundwater level in the well, when the groundwater level is not affected by pumping activities in the well; “surface casing” means a casing that surrounds the production casing of a well; “surface seal” means a sealant that (a) is installed in the annular space around the outside of the outermost casing and between multiple casings, and (b) extends to or just below the surface of the ground; “temporary” means, (a) in relation to a well, a well that is intended to be in service for a period of not more than 90 days after construction, and (b) in relation to a well pump, a well pump that is intended to remain installed in a well for a period of not more than 90 days after installation; “test pit” means an excavated geotechnical well that is intended to remain in service for a period of not more than 30 days after construction; “unconsolidated aquifer” means an aquifer composed of sediment, such as gravel or sand; “water supply well” means a well used or intended to be used for the purpose of exploring for, diverting or using groundwater, and includes a water source well, but does not include a drainage well, dewatering well or remediation well; “well construction report” means a report required under section 57 (1) [well reports] of the Act relating to the construction of a well; “well decommission report” means a report required under section 57 (1) of the Act relating to the decommissioning of a well; “well identification report” means a report required under section 55 (4) [well identification] of the Act relating to the identification of a well; “well pit” means an excavated artificial opening in the ground, lined with concrete, metal or wood, that contains a wellhead that is below the surface of the ground; “well tag number” means the file number assigned in the government's records to the records in relation to a particular well; “well yield test” means a flow test of a well that (a) is conducted by airlifting, bailing or a similar method, and (b) provides an approximate estimate of the capacity of the well to produce groundwater. (2) In the Act and this regulation: “flow test” means a pumping test or a well yield test; “flowing artesian well” means a well in which water, without the aid of a well pump, (a) rises above the surface of the ground or the top of the casing, if any, and (b) flows, either continuously or periodically. (3) For the purposes of sections 54 [attachment of well identification plates by owner of well supplying water supply system] and 63 [protection of water supply system wells from entry of foreign matter and physical damage], “owner” and “water supply system” have the same meaning as in section 55 of the Act.
Read the Groundwater Protection Regulation on BC Laws ↗

Made under Water Sustainability Act, SBC 2014, c. 15.