Ozone Depleting Substances and Other Halocarbons Regulation, B.C. Reg. 387/99

Section 27

Phase out of ozone depleting substances

Cite as Ozone Depleting Substances and Other Halocarbons Regulation, B.C. Reg. 387/99, s. 27 · last amended October 27, 2025 · read from BC Laws on November 17, 2026

The text

(1) Effective 6 months after the date this section comes into force, a person must not charge, or permit the charging of, a mobile refrigeration system with any Class I substance. (2) A person must not charge, or permit the charging, with any Class I substance, of the following systems: (a) effective January 1, 2006, a refrigeration system with a capacity of 4 KW or less; (b) effective January 1, 2007, a refrigeration system with a capacity greater than 4 KW and less than 22 KW; (c) effective January 1, 2008, a refrigeration system with a capacity of 22 KW or more; (d) effective January 1, 2006, all air conditioning systems. (3) Subsection (2) does not apply to a chiller, a household refrigerator, a household freezer or a water cooler. (4) Effective January 1, 2005, a person must not charge or permit the charging of a chiller with any Class I substance if the chiller has undergone an overhaul that includes the following procedure or repair: (a) the replacement or modification of an internal sealing device; (b) the replacement or modification of an internal mechanical part other than (i) an oil heater, (ii) an oil pump, (iii) a float assembly, or (iv) a vane assembly in the case of a chiller with a single-stage compressor; (c) any procedure or repair that resulted from the failure of an evaporator or a condenser heat-exchange tube. (5) Despite subsection (4), during the period January 1, 2005 to December 31, 2014, a person may charge or permit the charging of a chiller with a Class I substance, but the person must not operate that chiller later than one year after the charging unless it no longer contains a Class I substance. (6) The owner of a chiller referred to in subsection (5) must provide written notice to a director within 30 days after the chiller is charged. (7) On and after January 1, 2015, a person must not charge or permit the charging of a chiller with any Class I substance. (8) During the period January 1, 2005 to December 31, 2009, a person may charge or permit the charging of fixed fire extinguishing equipment with a Class I substance subject to the following restrictions: (a) the fixed fire extinguishing equipment may be charged with a Class I substance one time only; (b) within one year after the charging described in paragraph (a), (i) the fixed fire extinguishing equipment must be replaced with equipment that does not require the use of a Class I substance, or (ii) the fixed fire extinguishing equipment must be recharged with a substance that is not a Class I substance. (9) A person is exempt from the restrictions in subsection (8) (a) and (b) if the charging is necessary to prevent an immediate danger to human life or health. (10) Effective January 1, 2010, a person must not charge or permit the charging of fixed fire extinguishing equipment with any Class I substance.
Read the Ozone Depleting Substances and Other Halocarbons Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.