Code of Practice for the Concrete and Concrete Products Industry, B.C. Reg. 329/2007
Section 7
Authorized discharge: effluent and surface and marine water quality
Cite as Code of Practice for the Concrete and Concrete Products Industry, B.C. Reg. 329/2007, s. 7 · last amended January 1, 2008 · read from BC Laws on November 17, 2026
The text
(1) Process water of an establishment must not be discharged into surface water or marine water except in accordance with this section.
(2) A person operating an establishment
(a) must implement an effluent treatment system for the treatment of process water and establishment runoff discharged or flowing into surface water or marine water, and
(b) must ensure that such process water or establishment runoff
(i) has a pH level of no less than 6.5 and no more than 9,
(ii) contains no more than 75 mg/L total suspended solids,
(iii) contains no more than 15 mg/L total extractable hydrocarbons, and
(iv) is not acutely lethal to fish.
(3) The operator under subsection (2) must ensure that the effluent treatment system is inspected at least once a month to verify that it is in good working order.
(4) For the purposes of subsection (2) (b) (iv), “acutely lethal to fish”, in respect of any process water or establishment runoff, means that the process water or establishment runoff, at 100% concentration, kills more than 50% of the rainbow trout in a 96-hour LC50 rainbow trout bioassay.
Read the Code of Practice for the Concrete and Concrete Products Industry on BC Laws ↗
Made under Environmental Management Act, SBC 2003, c. 53.