Pool Regulation, B.C. Reg. 296/2010
Section 10
Pool water
Cite as Pool Regulation, B.C. Reg. 296/2010, s. 10 · last amended October 27, 2025 · read from BC Laws on November 17, 2026
The text
(1) In this section, “design flow rate” means the rate at which water must be recirculated or replaced in order to turn over the entire volume of pool water within a period of time specified in the plans submitted under section 5 [construction permit required].
(2) An operator must meet the following requirements in respect of water in the pool:
(a) pool water must be clear enough that
(i) the pattern of the main drain, or
(ii) a black disc of 150 mm in diameter over a white background,
located at the deepest point of the pool, can be seen clearly by a person standing on the edge of the pool overlooking the main drain or disc;
(b) pool water, except in a hot tub, must be maintained at a temperature of no more than 37C;
(c) the microbiological quality of pool water must not present a risk to the health of pool patrons;
(d) the pH level of pool water must be tested at least twice daily and maintained at no less than 7.2 and no more than 7.8;
(e) the alkalinity of pool water must be tested at least weekly and maintained at a level no less than 80 parts per million and no more than 120 parts per million;
(f) disinfectants used in pool water must be tested at least twice daily and maintained in accordance with Schedule 3;
(g) the combined chlorine in pool water must be tested at least twice daily and maintained at a concentration of less than one part per million;
(h) if cyanuric acid stabilizer is used in pool water, it must be tested at least weekly and maintained at a concentration of less than 80 parts per million;
(i) pool water must be recirculated or replaced at the design flow rate;
(j) pool water must be circulated through the skimmers or overflow gutters at a rate of flow at least equal to 50% of the design flow rate while the pool is in use;
(k) subject to subsection (3), pool water must not pass through any drain grate at a speed greater than 46 cm per second when the pool is operating at the design flow rate.
(3) A health officer may waive, in writing, the requirement set out in subsection (2) (k) in relation to a specified pool if
(a) the pool is used for exercise, commonly known as a "swim in place" pool, and
(b) the health officer is satisfied that the design of the pool will not create a suction hazard.
(3.1) A health officer may impose a different requirement than set out in subsection (2) (d), (e), (f) or (g) in relation to a specified pool if
(a) a more stringent requirement is, in the opinion of the health officer, necessary to prevent a health hazard, or
(b) the health officer is satisfied that the different requirement is sufficient to prevent a health hazard.
(4) In addition to any other power that may be exercised under the Act, a health officer may require an operator to test for chemical, physical or biological characteristics of water in a pool.