(1) A pipeline permit holder must not vent natural gas during an operation to depressure a pipeline unless
(a) the gas heating value, volume or flow rate are insufficient to support stable combustion,
(b) the venting is conducted in a manner that does not constitute a safety hazard,
(c) the venting does not cause off-site odours,
(d) the quantity of vented gas is minimized, and
(e) the duration of venting is minimized.
(2) Despite subsection (1) (a) a permit holder may vent natural gas if
(a) an operation to depressure a pipeline is needed to address an imminent risk to health, safety or the environment,
(b) natural gas conservation or destruction would result in an interruption of the natural gas supply to the public, or
(c) natural gas conservation or destruction equipment is not available at the site and it is not feasible to use portable conservation or destruction equipment due to access limitations or the configuration of the pipeline at the site.