Organic Matter Recycling Regulation, B.C. Reg. 18/2002

Schedule 2

Schedule 2

Cite as Organic Matter Recycling Regulation, B.C. Reg. 18/2002, Schedule 2 · last amended March 30, 2022 · read from BC Laws on November 17, 2026

The text

Schedule 2 Vector Attraction Reduction 1 One of the following vector attraction reduction processes is required for Class A biosolids or Class B biosolids used to produce biosolids growing medium: (a) a digestion process (aerobic or anaerobic) resulting in the mass of volatile solids of the biosolids being reduced by more than 38 percent; (b) when the 38 percent volatile solids reduction requirement in paragraph (a) cannot be met for an aerobically digested biosolids, vector attraction reduction can be demonstrated by digesting a portion of the previously digested biosolids that has a percent solids of two percent or less aerobically in the laboratory in a bench-scale unit for 30 additional days at 20° Celsius. When, at the end of the 30 days, the volatile solids in the biosolids at the beginning of that period is reduced by less than 15 percent, vector attraction reduction is achieved; (c) when the 38 percent volatile solids reduction requirement in paragraph (a) cannot be met for an anaerobically digested biosolids, vector attraction reduction can be demonstrated by digesting a portion of the previously digested biosolids anaerobically in the laboratory in a bench-scale unit for 40 additional days at a temperature between 30 and 37 Celsius. When, at the end of the 40 days, the volatile solids in the biosolids at the beginning of that period is reduced by less than 17 percent, vector attraction reduction is achieved; (d) the specific oxygen uptake rate (SOUR) for biosolids treated in an aerobic process shall be less than or equal to 1.5 milligrams of oxygen per hour per gram of total solids (dry weight basis) at a temperature of 20 Celsius; (e) the pH of biosolids shall be raised to 12 or higher by alkali addition and, without the addition of more alkali, shall remain at 12 or higher for two hours and then at 11.5 or higher for an additional 22 hours; (f) the percent solids of biosolids generated in a wastewater treatment process must be equal to or greater than 90 percent based on the moisture content and total solids prior to mixing with other materials. The biosolids must thereafter be managed in such a way that the moisture content of the biosolids does not increase such that compliance with the 90 percent solids requirement is maintained until such time as the biosolids is land applied in accordance with section 7 (2) or distributed in accordance with 7 (4) of this regulation. 2 One of the following vector attraction reduction processes are required for Class A compost: (a) Class A compost must be treated in an aerobic process for 14 days or longer. During that time, the temperature of the compost must be higher than 40° Celsius and the average temperature of the compost must be higher than 45° Celsius. After the vector attraction reduction process is completed the carbon to nitrogen ratio of the compost must be greater than or equal to 15:1 and less than or equal to 35:1; (b) Class A compost must be retained in curing piles for at least 21 days. After the 21 day period, the carbon to nitrogen ratio of the Class A compost must be greater than or equal to 15:1 and less than or equal to 35:1 and must not re-heat, upon standing, under the following conditions: (i) compost is aerated and formed into a pile no smaller than 3 metres in diameter and 2 metres high with compost having a moisture content between 35 percent and 60 percent; (ii) the pile must be formed in a location where the ambient temperature remains in the range of 5 to 30 Celsius; (iii) 3 days after the pile has been formed, the temperature of the compost is measured at a depth of 60 cm into the pile from the outside surface of the pile; (iv) the compost must not re-heat upon standing to greater than 20 Celsius above ambient temperature. 3 If one of the above vector attraction reduction methods cannot be met, then a test method or treatment process specified in protocols approved by the director, may be used as an alternative means of showing that vector attraction reduction has been achieved. 4 Class B biosolids must meet the vector attraction reduction processes specified in section 1 of this Schedule or meet one of the following alternatives: (a) if Class B biosolids, with fecal coliform levels determined to be < 2 000 000 MPN per gram of total solids, are injected into the soil, then the biosolids must be injected below the land surface within 8 hours after being discharged from the pathogen treatment process and no significant amount of biosolids must remain on the soil surface 1 hour after application; (b) if Class B biosolids, with fecal coliform levels determined to be < 2 000 000 MPN per gram of total solids, are incorporated by tillage, then the biosolids must be incorporated within 8 hours after being discharged from the pathogen treatment process and no significant amount of biosolids must remain on the soil surface 6 hours after application. 5 If Class B compost does not meet the vector attraction reduction processes specified in section 1 of this Schedule, and Class B compost is incorporated by tillage, then no significant amount of Class B compost must remain on the soil surface 6 hours after application. 6 If Class B biosolids or Class B compost is applied to soil using other technologies, practices or methods, Class B biosolids or Class B compost must be applied in accordance with best management practices described in the most recent edition of the organic matter recycling guidelines approved by the director.
Read the Organic Matter Recycling Regulation on BC Laws ↗

Made under Environmental Management Act, SBC 2003, c. 53.