Organic Matter Recycling Regulation, B.C. Reg. 18/2002

Schedule 1

Schedule 1

Cite as Organic Matter Recycling Regulation, B.C. Reg. 18/2002, Schedule 1 · last amended March 30, 2022 · read from BC Laws on November 17, 2026

The text

Schedule 1 Pathogen Reduction Processes 1 The pathogen reduction requirements listed in section 2 (a) to (g) of this Schedule must be met before or at the same time as the vector attraction reduction requirements set out in sections 1 to 3 of Schedule 2. 2 One of the following pathogen reduction methods is required for Class A biosolids or biosolids used to produce biosolids growing medium: (a) the thermophilic aerobic digestion method consisting of an aerobic process whereby liquid biosolids are agitated with air or oxygen under a temperature of not less than 55 Celsius for 30 minutes or longer, and the temperature and time period are determined using the equation in paragraph (f). The process is to be configured (batch, plug flow, staged) to maintain sufficient retention time to ensure that pathogen and volatile solids destruction is reliably achieved; (b) the thermophilic anaerobic digestion method consisting of a process whereby liquid biosolids are agitated in the absence of free oxygen (under negative Redox potential) at a temperature of not less than 50 Celsius for at least 10 consecutive days. The process must be configured (batch, plug flow, staged) to maintain sufficient retention time to ensure that pathogen and volatile solids destruction is reliably achieved; (c) the heat treatment method such that when the percent solids of the biosolids is 7 percent or higher, (i) the temperature of the biosolids must be 50 Celsius or higher, (ii) the time period must be 20 minutes or longer, and (iii) the minimum required time period must be determined using the following equation, except when small particles of biosolids are heated by either warmed gases or an immiscible liquid: D = 131 700 000/ 100.1400t where D = time in days t = temperatures in Celsius; (d) the heat treatment method such that when the percent solids of the biosolids is 7 percent or higher and small particles of biosolids are heated by either warmed gases or an immiscible liquid, (i) the temperature of the biosolids must be 50 Celsius or higher, (ii) the time period must be 15 seconds or longer, and (iii) the minimum required time period must be determined using the equation in paragraph (c); (e) the heat treatment method such that when the percent solids of the biosolids is less than 7 percent, (i) the time period must be at least 15 seconds but less than 30 minutes, and (ii) the minimum required time period must be determined using the equation in paragraph (c); (f) the heat treatment method such that when the percent solids of the biosolids is less than 7 percent, (i) the temperature of the biosolids must be 50° Celsius or higher, and (ii) the time period must be 30 minutes or longer, and (iii) the minimum required time period must be determined using the following equation: D = 50 070 000/100.1400t where D = time in days t = temperatures in Celsius; (g) the alkaline stabilization method consisting of maintaining the pH within the biosolids at above 12 for 72 hours with a temperature during the 72 hour period greater than 52 Celsius for 12 hours. After 72 hours at pH above 12, the biosolids must be air-dried to greater than 50 percent total solids. 3 The pathogen reduction requirements for Class A compost listed in section 4 (a) to (c) of this Schedule must be met before the vector attraction reduction requirements listed in section 2 (a) and (b) of Schedule 2. 4 One of the following pathogen reduction processes specified in paragraphs (a) to (c) is required to produce Class A compost: (a) the windrow composting method whereby organic matter is processed in a windrow involving periodic aeration and mixing of the windrow, with a temperature of not less than 55 Celsius maintained for at least 15 days and not fewer than 5 turnings of the windrow made during the high temperature period to promote uniform exposure of the compost to thermophilic temperatures; (b) the static aerated pile composting method consisting of a compost process involving mechanical aeration of the compost pile, with the compost pile insulated and a temperature of not less than 55 Celsius maintained throughout the compost pile for at least 3 consecutive days; (c) the enclosed vessel method consisting of a confined compost process involving mechanical aeration of compost under controlled environmental conditions, with a temperature of not less than 55 Celsius maintained for at least 3 days during the composting process. 5 To produce Class A compost from yard waste alone, a turning process can be used whereby the pile is turned on a periodic basis to aerate the yard waste, maintain optimum temperatures, and reduce pathogens. 6 The director may provide approval for an alternative process on a specific basis if the director is satisfied that the alternative process in that case will provide a Class A compost equivalent in quality as that produced by the process described by section 4 (a) to (c). 7 For Class B biosolids and Class B compost a biosolids treatment or composting process must be used whereby fecal coliform are reduced to levels < 2 000 000 MPN per gram of total solids (dry weight basis), or one of the following processes must be used: (a) the aerobic digestion process whereby Class B biosolids are agitated with air or oxygen to maintain aerobic conditions for a specific mean cell residence time at a specific temperature. Values for the mean cell residence time and temperature must be between 40 days at 20 Celsius and 60 days at 15 Celsius; (b) the air-drying process whereby Class B biosolids are dried on sand beds or on paved or unpaved basins. The biosolids must dry for a minimum of 3 months. During 2 of the 3 months, the ambient average daily temperature must be above 0 Celsius; (c) the anaerobic digestion process whereby Class B biosolids are treated in the absence of air for a specific mean cell residence time at a specific temperature. Values for the mean cell time and temperature must be between 15 days at 35 Celsius to 55 Celsius and 60 days at 20 Celsius; (d) the compost process using either within-vessel, static aerated pile or windrow-composting methods whereby the temperature of the Class B compost is raised to 40 Celsius or higher and maintained for 5 days. For 4 hours during the 5-day period, the temperature in the compost pile must exceed 55 Celsius; (e) the lime stabilization process whereby sufficient lime is added to the Class B biosolids to raise the pH of the biosolids to 12 after 2 hours of contact.
Read the Organic Matter Recycling Regulation on BC Laws ↗

Made under Public Health Act, SBC 2008, c. 28.