Energy Efficiency Standards Regulation, B.C. Reg. 14/2015
Section 31
Definitions
Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 31 · last amended April 24, 2023 · read from BC Laws on November 17, 2026
The text
In this Part:
“AFUE” means annual fuel utilization efficiency;
“AHRI” means the Air-Conditioning, Heating, and Refrigeration Institute;
“ANSI Z21.13-2004/CSA 4.9-2004” means ANSI standard ANSI Z21.13-2004/CSA 4.9-2004 entitled Gas-Fired Low Pressure Steam and Hot Water Boilers;
“ANSI Z21.50-2016/CSA 2.22-2016” means ANSI standard ANSI Z21.50-2016/CSA 2.22-2016 entitled Vented decorative gas appliances;
“ANSI Z21.88-2016/CSA 2.33-2016” means ANSI standard ANSI Z21.88-2016/CSA 2.33-2016 entitled Vented gas fireplace heaters;
“ANSI/AHRI 1500” means ANSI/AHRI standard ANSI/AHRI 1500 entitled 2015 Standard for Performance Rating of Commercial Space Heating Boilers;
“CAN/CSA C828-13” means CSA standard CAN/CSA C828-13 entitled Performance Requirements for Thermostats Used With Individual Room Electric Space Heating Devices;
“CAN/CSA P.2-13” means CSA standard CAN/CSA P.2-13 entitled Testing method for measuring the annual fuel utilization efficiency of residential gas-fired or oil-fired furnaces and boilers;
“CAN/CSA P.4.1-02” means CSA standard CAN/CSA P.4.1-02 entitled Testing Method for Measuring Annual Fireplace Efficiency;
“CAN/CSA P.4.1-15” means CSA standard CAN/CSA-P.4.1-15 entitled Testing method for measuring annual fireplace efficiency;
“commercial gas boiler” means a boiler that
(a) is fired by propane or natural gas,
(b) is intended for application in a hot water central heating system or in a potable water service, and
(c) has an input rating of
(i) no less than 87.92 kW (300 000 BTU/h), and
(ii) no more than 2 930.71 kW (10 000 000 BTU/h);
“commercial gas boiler — large” means a commercial gas boiler that has an input rating of
(a) more than 732.68 kW (2 500 000 BTU/h), and
(b) no more than 2 930.71 kW (10 000 000 BTU/h);
“commercial gas boiler — small” means a commercial gas boiler that has an input rating of
(a) no less than 87.92 kW (300 000 BTU/h), and
(b) no more than 732.68 kW (2 500 000 BTU/h);
“CSA C828:19” means CSA standard CSA C828:19 entitled Performance Requirements for Line Voltage Thermostats Used With Individual Room Electric Space Heating Devices;
“FE rating” means the annual fireplace efficiency rating of a gas fireplace, vented gas fireplace heater or vented decorative gas appliance;
“GAMA BTS-2000” means GAMA BTS-2000 standard of the Hydronics Institute Division of the Air Conditioning, Heating and Refrigeration Institute (USA) entitled Method to Determine Efficiency of Commercial Space Heating Boilers;
“gas fireplace” means a gas fireplace that uses propane or natural gas, including an insert or free-standing stove;
“gas furnace” has the same meaning as in the federal regulation;
“HSPF” means the heating seasonal performance factor, expressed in British thermal units per watt-hour or BTU/watt-hr;
“outdoor gas furnace” means a gas furnace that uses a single-phase electric current and is for use outdoors;
“replacement gas furnace” means a gas furnace for use as a replacement furnace in a residential building;
“residential gas boiler” means a boiler that
(a) is fired by propane or natural gas,
(b) is intended for application in a hot water central space heating system,
(c) may service a potable hot water system, and
(d) has an input rating of less than 87.92 kW (300 000 BTU/h);
“thermostat” means a thermostat used for switching of a controlled resistive 120 or 240 volt heating load, but does not include any of the following:
(a) a single thermostat used to control a central heating unit;
(b) a thermostat in a portable heater;
(c) a thermostat used exclusively to control
(i) a fan-forced heater,
(ii) a fireplace, or
(iii) a radiant floor heater;
(d) a built-in line voltage thermostat used to control a baseboard heater, or panel convector heater, that has a maximum rated heat output of 1 000 watts;
“through-the-wall gas furnace” means a through-the-wall gas furnace that uses a single-phase electric current;
“vented decorative gas appliance” means a vented decorative gas appliance that is within the scope of ANSI Z21.50-2016/CSA 2.22-2016;
“vented gas fireplace heater” means a vented gas fireplace heater that is within the scope of ANSI Z21.88-2016/CSA 2.33-2016.
Read the Energy Efficiency Standards Regulation on BC Laws ↗
Made under Energy Efficiency Act, RSBC 1996, c. 114.