Energy Efficiency Standards Regulation, B.C. Reg. 14/2015

Section 31

Definitions

Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 31 · last amended April 24, 2023 · read from BC Laws on November 17, 2026

The text

In this Part: “AFUE” means annual fuel utilization efficiency; “AHRI” means the Air-Conditioning, Heating, and Refrigeration Institute; “ANSI Z21.13-2004/CSA 4.9-2004” means ANSI standard ANSI Z21.13-2004/CSA 4.9-2004 entitled Gas-Fired Low Pressure Steam and Hot Water Boilers; “ANSI Z21.50-2016/CSA 2.22-2016” means ANSI standard ANSI Z21.50-2016/CSA 2.22-2016 entitled Vented decorative gas appliances; “ANSI Z21.88-2016/CSA 2.33-2016” means ANSI standard ANSI Z21.88-2016/CSA 2.33-2016 entitled Vented gas fireplace heaters; “ANSI/AHRI 1500” means ANSI/AHRI standard ANSI/AHRI 1500 entitled 2015 Standard for Performance Rating of Commercial Space Heating Boilers; “CAN/CSA C828-13” means CSA standard CAN/CSA C828-13 entitled Performance Requirements for Thermostats Used With Individual Room Electric Space Heating Devices; “CAN/CSA P.2-13” means CSA standard CAN/CSA P.2-13 entitled Testing method for measuring the annual fuel utilization efficiency of residential gas-fired or oil-fired furnaces and boilers; “CAN/CSA P.4.1-02” means CSA standard CAN/CSA P.4.1-02 entitled Testing Method for Measuring Annual Fireplace Efficiency; “CAN/CSA P.4.1-15” means CSA standard CAN/CSA-P.4.1-15 entitled Testing method for measuring annual fireplace efficiency; “commercial gas boiler” means a boiler that (a) is fired by propane or natural gas, (b) is intended for application in a hot water central heating system or in a potable water service, and (c) has an input rating of (i) no less than 87.92 kW (300 000 BTU/h), and (ii) no more than 2 930.71 kW (10 000 000 BTU/h); “commercial gas boiler — large” means a commercial gas boiler that has an input rating of (a) more than 732.68 kW (2 500 000 BTU/h), and (b) no more than 2 930.71 kW (10 000 000 BTU/h); “commercial gas boiler — small” means a commercial gas boiler that has an input rating of (a) no less than 87.92 kW (300 000 BTU/h), and (b) no more than 732.68 kW (2 500 000 BTU/h); “CSA C828:19” means CSA standard CSA C828:19 entitled Performance Requirements for Line Voltage Thermostats Used With Individual Room Electric Space Heating Devices; “FE rating” means the annual fireplace efficiency rating of a gas fireplace, vented gas fireplace heater or vented decorative gas appliance; “GAMA BTS-2000” means GAMA BTS-2000 standard of the Hydronics Institute Division of the Air Conditioning, Heating and Refrigeration Institute (USA) entitled Method to Determine Efficiency of Commercial Space Heating Boilers; “gas fireplace” means a gas fireplace that uses propane or natural gas, including an insert or free-standing stove; “gas furnace” has the same meaning as in the federal regulation; “HSPF” means the heating seasonal performance factor, expressed in British thermal units per watt-hour or BTU/watt-hr; “outdoor gas furnace” means a gas furnace that uses a single-phase electric current and is for use outdoors; “replacement gas furnace” means a gas furnace for use as a replacement furnace in a residential building; “residential gas boiler” means a boiler that (a) is fired by propane or natural gas, (b) is intended for application in a hot water central space heating system, (c) may service a potable hot water system, and (d) has an input rating of less than 87.92 kW (300 000 BTU/h); “thermostat” means a thermostat used for switching of a controlled resistive 120 or 240 volt heating load, but does not include any of the following: (a) a single thermostat used to control a central heating unit; (b) a thermostat in a portable heater; (c) a thermostat used exclusively to control (i) a fan-forced heater, (ii) a fireplace, or (iii) a radiant floor heater; (d) a built-in line voltage thermostat used to control a baseboard heater, or panel convector heater, that has a maximum rated heat output of 1 000 watts; “through-the-wall gas furnace” means a through-the-wall gas furnace that uses a single-phase electric current; “vented decorative gas appliance” means a vented decorative gas appliance that is within the scope of ANSI Z21.50-2016/CSA 2.22-2016; “vented gas fireplace heater” means a vented gas fireplace heater that is within the scope of ANSI Z21.88-2016/CSA 2.33-2016.
Read the Energy Efficiency Standards Regulation on BC Laws ↗

Made under Energy Efficiency Act, RSBC 1996, c. 114.