Energy Efficiency Standards Regulation, B.C. Reg. 14/2015
Section 27
Efficiency standards for manufactured fenestration products
Cite as Energy Efficiency Standards Regulation, B.C. Reg. 14/2015, s. 27 · last amended April 24, 2023 · read from BC Laws on November 17, 2026
The text
The following efficiency standards table sets out the efficiency standards for energy devices that are manufactured fenestration products: Item Column 1
Energy
Device Column 2
Prescribed Date (s. 2 (3) (a) of Act) Column 3
Manufacturing
Period Column 4
Efficiency Standard Column 5
Testing Procedure 1 Door slabs
(for exclusions, see sections 16 (2) and 17) June 1, 2009 Products manufactured on or after June 2, 2009 The door panels must be insulated with products with an
RSI ≥ 0.875 m2×K/W ASTM C518-04 or ASTM C518-10 2 Glazing products
(for exclusions, see sections 16 (3) and 18) June 1, 2009 Products manufactured on or after June 2, 2009 The glazing product
(a) must be multiple glazed with at least one low-emissivity coating between glazing,
(b) must have a 90% argon gas fill level with a compatible edge sealant system, and
(c) must have spacer bars and if the spacer bars are aluminum box spacer bars, the aluminum box spacer bars must have a thermal break. Not applicable 3 Non-metal, non-wood framed windows and sliding glass doors (for smaller buildings)
(for exclusions, see sections 16 (4) and 19) March 1, 2009 Products manufactured between March 2, 2009 and June 1, 2018 U-value must be
≤ 2.0 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 3.1 Non-metal, non-wood framed windows and sliding glass doors (for smaller buildings)
(for exclusions, see sections 16 (4) and 19) June 1, 2018 Products manufactured between June 2, 2018 and January 1, 2022 U-value must be
≤ 1.80 W/[m2×K] The procedure set out in one of the following:
(a) CAN-CSA A440.2-14/A440.3-14;
(b) NFRC 100-2014. 4 Wood framed windows and sliding glass doors (for smaller buildings)
(for exclusions, see sections 16 (5) and 19) Jan 1, 2011 Products manufactured between Jan 2, 2011 and June 1, 2018 U-value must be
≤ 2.0 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 4.1 Wood framed windows and sliding glass doors (for smaller buildings)
(for exclusions, see sections 16 (5) and 19) June 1, 2018 Products manufactured between June 2, 2018 and January 1, 2022 U-value must be
≤ 1.80 W/[m2×K] The procedure set out in one of the following:
(a) CAN-CSA A440.2-14/A440.3-14;
(b) NFRC 100-2014. 4.2 Windows and sliding glass doors (for smaller buildings)
(for exclusions, see sections 16 (5.1) and 19) Jan 1, 2022 Products manufactured on or after Jan 2, 2022 U-value must be ≤ 1.61 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-14/A440.3-14;
(b) CAN/CSA A440.2-19/A440.3-19;
(c) NFRC 100-2014;
(d) NFRC 100-2017. 5 Skylights
(for exclusions, see section 16 (6)) March 1, 2009 Products manufactured between March 2, 2009 and June 1, 2018 U-value must be
≤ 3.10 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 5.1 Skylights
(for exclusions, see section 16 (6)) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 2.90
W/[m2×K] The procedure set out in one of the following:
(a) CAN-CSA A440.2-14/A440.3-14;
(b) NFRC 100-2014. 6 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for smaller buildings)
(for exclusions, see sections 16 (7) and 19) June 1, 2009 Products manufactured between June 2, 2009 and Jan 1, 2011 U-value must be
≤ 2.57 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 7 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for smaller buildings)
(for exclusions, see sections 16 (7) and 19) Jan 1, 2011 Products manufactured between Jan 2, 2011 and June 1, 2018 U-value must be
≤ 2.0 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 7.1 Metal framed curtain walls, window walls and storefront windows (for smaller buildings)
(for exclusions, see sections 16 (7) and 19) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 1.80
W/[m2×K] The procedure set out in one of the following:
(a) CAN-CSA A440.2-14/A440.3-14;
(b) NFRC 100-2014.
7.2 Non-metal curtain walls, window walls and storefront windows (for smaller buildings)
(for exclusions, see sections 16 (7.1) and 19) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 1.80
W/[m2×K] The procedure set out in one of the following:
(a) CAN-CSA A440.2-14/A440.3-14;
(b) NFRC 100-2014. 8 Hinged and bi-folding doors (for smaller buildings)
(for exclusions, see sections 16 (8) and 19) Jan 1, 2012 Products manufactured between Jan 2, 2012 and June 1, 2018 U-value must be ≤ 2.0
W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 8.1 Hinged and bi-folding doors (for smaller buildings)
(for exclusions, see sections 16 (8) and 19) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 1.80
W/[m2×K] The procedure set out in one of the following:
(a) CAN-CSA A440.2-14/A440.3-14;
(b) NFRC 100-2014. 9 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings)
(for exclusions, see sections 16 (9) and 20) Jan 1, 2011 Products manufactured on or after Jan 2, 2011 U-value must be
≤ 2.57 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010. 10 Non-metal windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings)
(for exclusions, see sections 16 (10) and 20) Jan 1, 2011 Products manufactured on or after Jan 2, 2011 U-value must be
≤ 2.0 W/[m2×K] The procedure set out in one of the following:
(a) CAN/CSA A440.2-04/A440.3-04;
(b) CAN/CSA A440.2-09/A440.3-09;
(c) NFRC 100-2004 or NFRC 100-2010.
Read the Energy Efficiency Standards Regulation on BC Laws ↗